← Back
Two stories - detached, small or mid-size
4274 OCEAN AVENUE
BROOKLYN · BIN 3246347
💬 Discuss this project
1925Year Built
2Stories
A1Building Class
R3-1Zoning
1,984 sfGross Floor Area
1Units
0 Open ViolationsFDNY Report ↗
Two stories - detached, small or mid-size · 3,224 sf lot · 0.62 FAR built · Flood zone AE
Locations of Work
ArchitectureStructuralMechanicalPlumbing
Permit Issued — active, not yet Signed-off
RoofUnder Construction1 filing · 20 docs
Floor 2Under Construction1 filing · 20 docs
Floor 1Under Construction1 filing · 20 docs
CellarUnder Construction1 filing · 20 docs
Sub-BasementUnder Construction1 filing · 20 docs
▾Sales History (ACRIS)
DatePriceUnitSeller → Buyer$/sf
05/02/2017$1.7M—— → —$857/sf building
▾Design Consultants (Architect / Engineer of Record)
FirmFilingsMost Recent
RSLN ARCHITECTURE PLLC302/23/2026
VERSATILE ENGINEERING, P.C.312/29/2025
▾Contractors (License-Anchored)
FirmTradeRolesMost Recent
PLANET RENOVATIONS INCGeneral Contractor407/10/2026
NICE PLUMBING CORPPlumbing107/08/2026
▾Special Inspection Agencies
AgencyLicense #FilingsMost Recent
STEEL CORE ENGINEERING PL1098602/23/2026
Building Lifecycle
All (89)Filed (6)Permit Issued (5)Violation (2)Inspection (2)Objection (44)Special Inspection (30)
07/30/2026
Inspection — Certified Water and Sanitary-WS-Sanitary Piping-Roughing
Certified
View inspection ↗
07/08/2026
Permit issued — Structural
B01261492-S2-ST
07/08/2026
Permit issued — Foundation
B01261492-S3-FO
05/21/2026
Permit issued — Plumbing
B01261492-S4-PL
05/18/2026
Inspection — Pass-Final CND-Occupancy Inspection
Pass
View inspection ↗
04/21/2026
Permit issued — General Construction
B01261492-I1-GC
04/16/2026
Permit issued — Mechanical Systems
B01261492-S5-MS
04/15/2026
Objection resolved — Resolved
04/10/2026
Objection resolved — Addressed
04/06/2026
Objection resolved — Addressed
04/06/2026
Objection resolved — Addressed
03/19/2026
Objection resolved — Addressed
03/19/2026
Objection resolved — Addressed
03/19/2026
Objection resolved — Addressed
02/23/2026
Filed — Alteration
FOUNDATION WORK FOR HORIZONTAL ENLARGEMENT OF EXISTING 3-STORY TWO FAMILY HOUSE
B01261492-S4
02/23/2026
Filed — Alteration
FOUNDATION WORK FOR HORIZONTAL ENLARGEMENT OF EXISTING 3-STORY TWO FAMILY HOUSE
B01261492-S5
02/23/2026
Special inspection requirement — Energy Code Compliance Inspections
Alexander Sheyman
02/23/2026
Special inspection requirement — Heating Systems
Alexander Sheyman
02/23/2026
Special inspection requirement — Fire-Resistant Penetrations and Joints
Alexander Sheyman
02/23/2026
Special inspection requirement — Duct leakage testing, insulation and design
Alexander Sheyman
02/23/2026
Special inspection requirement — Permanent certificate
Alexander Sheyman
02/23/2026
Special inspection requirement — Maintenance information
Alexander Sheyman
02/23/2026
Special inspection requirement — Fire-Resistant Penetrations and Joints
Alexander Sheyman
02/23/2026
Special inspection requirement — Flood Zone Compliance (attach FEMA elevation/dry floodproofing certificate where applicable)
Alexander Sheyman
02/23/2026
Special inspection requirement — Private On-Site Storm Water Disposal Systems-, and Detention Facilities, Installation
Alexander Sheyman
02/23/2026
Special inspection requirement — Energy Code Compliance Inspections
Alexander Sheyman
02/23/2026
Special inspection requirement — HVAC-R and service water heating equipment
Alexander Sheyman
02/23/2026
Special inspection requirement — HVAC-R and service water heating system controls
Alexander Sheyman
02/23/2026
Special inspection requirement — Maintenance information
Alexander Sheyman
02/23/2026
Special inspection requirement — Permanent certificate
Alexander Sheyman
02/23/2026
Special inspection requirement — HVAC-R and service water piping design and insulation
Alexander Sheyman
02/23/2026
Special inspection requirement — HVAC-R and service water piping design and insulation
Alexander Sheyman
02/23/2026
Special inspection requirement — HVAC-R and service water heating equipment
Alexander Sheyman
02/23/2026
Special inspection requirement — HVAC-R and service water heating system controls
Alexander Sheyman
02/05/2026
Objection resolved — Addressed
02/05/2026
Objection resolved — Addressed
01/12/2026
Objection resolved — Addressed
01/12/2026
Objection resolved — Addressed
01/12/2026
Objection resolved — Addressed
01/12/2026
Objection resolved — Addressed
01/11/2026
Special inspection requirement — Structural Stability – Alterations of existing buildings
Alexander Sheyman
01/11/2026
Special inspection requirement — Concrete - Cast-In-Place
Alexander Sheyman
01/11/2026
Special inspection requirement — Wood – Prefabricated I-Joists
Alexander Sheyman
01/09/2026
Objection raised — Structural
01/09/2026
Objection raised — Structural
01/09/2026
Objection raised — Structural
01/09/2026
Objection raised — Admin
01/09/2026
Objection raised — Admin
01/09/2026
Objection raised — Structural
01/09/2026
Objection raised — Structural
01/09/2026
Objection raised — Scope
01/09/2026
Objection raised — Structural
01/09/2026
Objection raised — Structural
01/09/2026
Objection raised — Structural
01/09/2026
Objection raised — Structural
01/02/2026
Objection resolved — Addressed
12/31/2025
Objection raised — Other
12/29/2025
Filed — Alteration
FOUNDATION WORK FOR HORIZONTAL ENLARGEMENT OF EXISTING 3-STORY TWO FAMILY HOUSE
B01261492-S2
12/29/2025
Filed — Alteration
FOUNDATION WORK FOR HORIZONTAL ENLARGEMENT OF EXISTING 3-STORY TWO FAMILY HOUSE
B01261492-S3
12/29/2025
Filed — Alteration
FOUNDATION WORK FOR HORIZONTAL ENLARGEMENT OF EXISTING 3-STORY TWO FAMILY HOUSE
B01261492-S1
Latest 60 of 89 events.
Permit / Filing Register
SourceWork TypeStatusApplicantIssued
DOB NOWStructuralPermit IssuedPLANET RENOVATIONS INC07/08/2026
DOB NOWFoundationPermit IssuedPLANET RENOVATIONS INC07/08/2026
DOB NOWPlumbingPermit IssuedNICE PLUMBING CORP05/21/2026
DOB NOWGeneral ConstructionPermit IssuedPLANET RENOVATIONS INC04/21/2026
DOB NOWMechanical SystemsPermit IssuedPLANET RENOVATIONS INC04/16/2026
BISOTISSUEDOMNI BUILD INC03/22/2017
BISPLISSUEDROM PIPING & HTG INC01/11/2017
BISOTISSUEDOMNI BUILD INC01/03/2017
1 job · most recent 05/07/2026
General Wiring
FiledStatusContractorScope
05/07/2026Permit IssuedFOREST BROOK ELEC'L CONTRGeneral Wiring
1 job · most recent 02/23/2026
Concrete Masonry Wood
FiledStatusContractorScope
02/23/2026Permit IssuedPLANET RENOVATIONS INCConcrete, Masonry, Wood
▾Field Inspections (DOB CAP) — 2
DateTypeResultReport
07/30/2026Certified Water and Sanitary-WS-Sanitary Piping-RoughingCertifiedView ↗
05/18/2026Pass-Final CND-Occupancy InspectionPassView ↗
▾Special Inspection Requirements (DOB NOW) — 41
DateRequirementInspectorRole
02/23/2026Energy Code Compliance InspectionsAlexander Sheymanprogress
02/23/2026Heating SystemsAlexander Sheymanspecial
02/23/2026Fire-Resistant Penetrations and JointsAlexander Sheymanspecial
02/23/2026Duct leakage testing, insulation and designAlexander Sheymanenergy_progress
02/23/2026Permanent certificateAlexander Sheymanenergy_progress
02/23/2026Maintenance informationAlexander Sheymanenergy_progress
02/23/2026Fire-Resistant Penetrations and JointsAlexander Sheymanspecial
02/23/2026Flood Zone Compliance (attach FEMA elevation/dry floodproofing certificate where applicable)Alexander Sheymanspecial
02/23/2026Private On-Site Storm Water Disposal Systems-, and Detention Facilities, InstallationAlexander Sheymanspecial
02/23/2026Energy Code Compliance InspectionsAlexander Sheymanprogress
02/23/2026HVAC-R and service water heating equipmentAlexander Sheymanenergy_progress
02/23/2026HVAC-R and service water heating system controlsAlexander Sheymanenergy_progress
02/23/2026Maintenance informationAlexander Sheymanenergy_progress
02/23/2026Permanent certificateAlexander Sheymanenergy_progress
02/23/2026HVAC-R and service water piping design and insulationAlexander Sheymanenergy_progress
02/23/2026HVAC-R and service water piping design and insulationAlexander Sheymanenergy_progress
02/23/2026HVAC-R and service water heating equipmentAlexander Sheymanenergy_progress
02/23/2026HVAC-R and service water heating system controlsAlexander Sheymanenergy_progress
01/11/2026Structural Stability – Alterations of existing buildingsAlexander Sheymanspecial
01/11/2026Concrete - Cast-In-PlaceAlexander Sheymanspecial
01/11/2026Wood – Prefabricated I-JoistsAlexander Sheymanspecial
12/23/2025MasonryAlexander Sheymanspecial
12/23/2025Subgrade InspectionsAlexander Sheymanspecial
12/23/2025Structural Cold-Formed SteelAlexander Sheymanspecial
10/24/2025FinalAlexander Sheymanprogress
Latest 25 of 41.
▾Documents — 55 on file (BIS + DOB NOW)
▸Plans & Drawings6
▸DOB NOWPlans/Sketch6
08/19/2026B01261492-S5Request digital key ↗
08/19/2026B01261492-S4Request digital key ↗
08/15/2026B01261492-I1Request digital key ↗
Showing 3 of 6 on file for this type
▸Applications & Permits4
▸BISWORK PERMIT APPLICATION3
03/28/2017321504181Open ↗
01/11/2017321504181Open ↗
01/04/2017321504181Open ↗
▸BISPLAN / WORK APPROVAL APPLICATION1
01/04/2017321504181Open ↗
▸Zoning, Tax Lot & Property Records1
▸DOB NOWZD1: DOB Zoning Diagram1
08/13/2026B01261492-I1Open ↗
▸Seals & Professional Certifications26
▸DOB NOWProgress Inspector Seal & Signature8
09/01/2026B01261492-S4Open ↗
09/01/2026B01261492-S4Open ↗
08/27/2026B01261492-I1Open ↗
Showing 3 of 8 on file for this type
▸DOB NOWDPL-1: Design Professional Seal & Signature7
08/19/2026B01261492-S3Open ↗
08/13/2026B01261492-S4Open ↗
08/13/2026B01261492-S2Open ↗
Showing 3 of 7 on file for this type
▸DOB NOWSpecial Inspector Seal & Signature7
09/01/2026B01261492-S4Open ↗
09/01/2026B01261492-S4Open ↗
08/27/2026B01261492-I1Open ↗
Showing 3 of 7 on file for this type
▸BISTECHNICAL REPORT: RESPONSIBILITY/CERTIFICATION2
04/11/2017321504181Open ↗
04/11/2017321504181Open ↗
▸BISProfessional and Owner Certification (POC3)1
01/04/2017321504181Open ↗
▸BISPROFESSIONAL CERTIFIED CHECKLIST1
01/04/2017321504181Open ↗
▸Trade Schedules & Equipment1
▸BISSCHEDULE B - PLUMBING/SPRINKLER/STANDPIPE1
01/04/2017321504181Open ↗
▸Environmental & Asbestos4
▸DOB NOWDEP ACP-5: Asbestos Assessment Report4
08/14/2026B01261492-S3Open ↗
08/13/2026B01261492-I1Open ↗
08/13/2026B01261492-S5Open ↗
Showing 3 of 4 on file for this type
▸Inspections & Test Reports3
▸DOB NOWGeotechnical Report (BC 1803.6)3
08/15/2026B01261492-S1Open ↗
08/13/2026B01261492-S3Open ↗
08/13/2026B01261492-S1Open ↗
▸Approvals, Objections & Sign-offs1
▸BISCERTIFICATE OF OCCUPANCY/LOC: REQUEST1
04/11/2017321504181Open ↗
▸Cost, Insurance & Ownership2
▸BISCOST AFFIDAVIT2
04/11/2017321504181Open ↗
01/04/2017321504181Open ↗
▸Filing & Intake Forms1
▸BISEFILING COVER SHEET1
01/05/2017321504181Open ↗
▸Other Documents6
▸DOB NOWPlot Diagram3
08/13/2026B01261492-I1Open ↗
08/13/2026B01261492-S3Open ↗
08/13/2026B01261492-S1Open ↗
▸DOB NOWPARTIAL DEMO: 10-DAY Notice1
08/14/2026B01261492-S2Open ↗
▸DOB NOWLocal Law 92/94 of 2019 Sustainable Roof Zone1
08/13/2026B01261492-I1Open ↗
▸DOB NOWSite Survey: Initial1
08/13/2026B01261492-I1Open ↗