| Owner | Filings | Most Recent |
|---|---|---|
| Z H L GROUP | 8 | 04/09/2026 |
| 428 EAST 9 | 72 | 04/09/2026 |
| NEW AMERICAN CONSTRUCTION INC | 21 | 04/09/2026 |
| Date | Price | Unit | Seller → Buyer | $/sf |
|---|---|---|---|---|
| 01/27/2022 | $3.0M | — | — → — | — not available |
| Firm | Filings | Most Recent |
|---|---|---|
| Z ARCHITECTURE PLLC | 6 | 05/12/2025 |
| LEVIN ENGINEERING PLLC | 9 | 03/03/2025 |
| MJE PROFESSIONAL SERVICES | 6 | 12/08/2023 |
| STRUCTURAL ENGINEERING TECHNOLOGIES | 6 | 07/07/2023 |
| PROJECT TACTICAL SOLUTIONS, LLC | 2 | 06/09/2023 |
| INM ARCHITECTS PC | 1 | 11/17/2022 |
| ANTHONY GENNARO, PE | 1 | 11/17/2022 |
| Representative | Filings | Most Recent |
|---|---|---|
| LEVIN ENGINEERING PLLC | 18 | 03/21/2026 |
| CMCG | 20 | 03/21/2026 |
| BMB BUILDING CONSULTING | 2 | 03/21/2026 |
| BSGNY | 4 | 03/21/2026 |
| IOR DESIGN & CONSULTING | 4 | 03/21/2026 |
| Firm | Trade | Roles | Most Recent |
|---|---|---|---|
| TERRA DEVELOPERS, LLC | General Contractor | 15 | 04/09/2026 |
| NEW AMERICAN CONSTRUCTION INC | General Contractor | 11 | 04/09/2026 |
| M&D FIRE SPRINKLER INC | Fire Protection | 5 | 07/08/2026 |
| RITE WAY HEATING CORP | Plumbing | 2 | 07/08/2026 |
| ATLAS TECHNICAL ASSOCIATES | General Contractor | 1 | 03/22/2026 |
| CONTACT PLUS ELEC'L CORP | Electrical | 1 | 03/22/2026 |
| YM PRO CORP | General Contractor | 1 | 04/09/2026 |
| Agency | License # | Filings | Most Recent |
|---|---|---|---|
| CONCRETE SOLUTIONS LAB CO | 5344 | 20 | 05/12/2025 |
| Source | Work Type | Status | Applicant | Issued |
|---|---|---|---|---|
| DOB NOW | Curb Cut | Signed-off | TERRA DEVELOPERS, LLC | 02/18/2025 |
| DOB NOW | Mechanical Systems | Signed-off | TERRA DEVELOPERS, LLC | 01/03/2025 |
| DOB NOW | Sidewalk Shed | Signed-off | NEW AMERICAN CONSTRUCTION | 07/26/2024 |
| DOB NOW | Construction Fence | Signed-off | TERRA DEVELOPERS, LLC | 06/03/2024 |
| DOB NOW | General Construction | Permit Issued | TERRA DEVELOPERS, LLC | 05/06/2024 |
| DOB NOW | Sprinklers | Signed-off | M&D FIRE SPRINKLER INC | 05/01/2024 |
| DOB NOW | Plumbing | Signed-off | LS PLUMBING CORP | 04/30/2024 |
| DOB NOW | Standpipe | Signed-off | M&D FIRE SPRINKLER INC | 04/30/2024 |
| DOB NOW | Mechanical Systems | Signed-off | TERRA DEVELOPERS, LLC | 11/14/2023 |
| DOB NOW | Standpipe | Signed-off | M&D FIRE SPRINKLER INC | 11/01/2023 |
| DOB NOW | Sprinklers | Signed-off | M&D FIRE SPRINKLER INC | 11/01/2023 |
| DOB NOW | Standpipe | Signed-off | M&D FIRE SPRINKLER INC | 10/31/2023 |
| DOB NOW | Supported Scaffold | Signed-off | NEW AMERICAN CONSTRUCTION | 10/06/2023 |
| DOB NOW | Protection and Mechanical Methods | Signed-off | NEW AMERICAN CONSTRUCTION | 09/20/2023 |
| DOB NOW | Protection and Mechanical Methods | Signed-off | NEW AMERICAN CONSTRUCTION | 08/31/2023 |
| DOB NOW | Sidewalk Shed | Signed-off | NEW AMERICAN CONSTRUCTION | 08/25/2023 |
| DOB NOW | Structural | Signed-off | TERRA DEVELOPERS, LLC | 08/16/2023 |
| DOB NOW | Plumbing | Signed-off | LS PLUMBING CORP | 07/18/2023 |
| DOB NOW | Construction Fence | Signed-off | TERRA DEVELOPERS, LLC | 05/26/2023 |
| DOB NOW | Foundation | Signed-off | TERRA DEVELOPERS, LLC | 05/17/2023 |
| DOB NOW | Support of Excavation | Signed-off | TERRA DEVELOPERS, LLC | 05/11/2023 |
| DOB NOW | General Construction | Permit Issued | TERRA DEVELOPERS, LLC | 05/10/2023 |
| DOB NOW | Construction Fence | Signed-off | YM PRO CORP | 10/04/2022 |
| Filed | Status | Contractor | Scope | Make / Model / Capacity |
|---|---|---|---|---|
| 05/12/2025 | Signed-off | TERRA DEVELOPERS, LLC | Air Conditioning Systems | Cooling Samsung AM036TXMDCH 24 tons · Vrf Indoor ×35 AM036TXMDCH,AR12CSDACWKX, 30 tons · Vrf Outdoor ×9 AM048TXMDCH,AM036TXMDCH,AM060MXMDCH,AM12TNVDCH 30 tons · Vrf Outdoor ×9 AM036TXMDCH, 24 tons ×8 AR12CSDACWKX,AM048TXMDCH,AM036TXMDCH 64 tons · Split System ×8 AM036TXMDCH, AR12CSDACWKX 6 tons · Vrf Outdoor ×2 |
| Filed | Status | Contractor | Scope |
|---|---|---|---|
| 05/12/2025 | Signed-off | RITE WAY HEATING CORP | Gas, Storm, Water/Sanitary |
| Filed | Status | Contractor | Scope |
|---|---|---|---|
| 02/17/2025 | Complete | CONTACT PLUS ELEC'L CORP | General Wiring |
| 11/30/2023 | Complete | POWER DIRECT ELECTRIC INC | — |
| 08/25/2023 | Complete | RICHARD NEU | — |
| 11/21/2022 | Complete | A.R.I.S. ELECTRIC INC | 1 meters, 1 new_meters |
| Filed | Status | Contractor | Scope |
|---|---|---|---|
| 05/12/2025 | Signed-off | TERRA DEVELOPERS, LLC | Concrete |
| Date | Type | Result | Report |
|---|---|---|---|
| 05/23/2025 | Pass-Final CND-Occupancy Inspection | Pass | View ↗ |
| 05/19/2025 | Pass-Final Curb Cut Non-Directive 14 | Pass | View ↗ |
| 02/27/2025 | Certified Sprinkler-SP-Piping Dry/Wet-Hydrostatic Test | Certified | View ↗ |
| 02/24/2025 | Fail-Final Curb Cut Non-Directive 14 | Fail | View ↗ |
| 02/07/2025 | Certified Sprinkler-Dry Pipe Valve (SP)-Dry Pipe Valve Test | Certified | View ↗ |
| 02/07/2025 | Certified Sprinkler-SP-Fixtures-Finish | Certified | View ↗ |
| 02/01/2025 | Pass-Final CND-Occupancy Inspection | Pass | View ↗ |
| 11/19/2024 | Certified Sprinkler-SP-Fixtures-Finish | Certified | View ↗ |
| 11/15/2024 | Certified Remove/Cap - work done in accordance with code | Certified | View ↗ |
| 11/15/2024 | Certified Sprinkler-SP-Piping Dry/Wet-Hydrostatic Test | Certified | View ↗ |
| 08/27/2024 | Pass-Final CND-Occupancy Inspection | Pass | View ↗ |
| 03/06/2024 | Certified Gas-Gas-Piping-Roughing | Certified | View ↗ |
| 11/16/2023 | Certified StandPipe - SD - Hydrostatic 63/09 Test (Initial 75 Feet) | Certified | View ↗ |
| 08/30/2023 | Certified Water and Sanitary-WS-Sanitary Piping-Underground | Certified | View ↗ |
| 08/21/2023 | Certified Storm Drainage-ST-Piping-Underground | Certified | View ↗ |
| 08/21/2023 | Certified Water and Sanitary-WS-Sanitary Piping-Underground | Certified | View ↗ |
| 07/21/2023 | Certified Storm Drainage-ST-Piping-Underground | Certified | View ↗ |
| Date | Requirement | Inspector | Role |
|---|---|---|---|
| 05/12/2025 | Exterior Insulation and Finish Systems (EIFS) | MINA HANNA | special |
| 05/12/2025 | Metering | MINA HANNA | energy_progress |
| 05/12/2025 | Maintenance information | MINA HANNA | energy_progress |
| 05/12/2025 | Insulation placement and R values | MINA HANNA | energy_progress |
| 05/12/2025 | Electrical motors and elevators | MINA HANNA | energy_progress |
| 05/12/2025 | Interior lighting power | MINA HANNA | energy_progress |
| 05/12/2025 | Lighting controls | MINA HANNA | energy_progress |
| 05/12/2025 | Protection of exposed foundation insulation | MINA HANNA | energy_progress |
| 05/12/2025 | Lighting in dwelling units | MINA HANNA | energy_progress |
| 05/12/2025 | Air barrier - visual inspection | MINA HANNA | energy_progress |
| 05/12/2025 | Fenestration and door U-factor and product ratings | MINA HANNA | energy_progress |
| 05/12/2025 | Fenestration air leakage | MINA HANNA | energy_progress |
| 05/12/2025 | Fenestration areas | MINA HANNA | energy_progress |
| 05/12/2025 | Exterior lighting power | MINA HANNA | energy_progress |
| 05/12/2025 | Wall Panels, Curtain Walls, and Veneers | MINA HANNA | special |
| 05/12/2025 | Fire-Resistant Penetrations and Joints | MINA HANNA | special |
| 04/01/2025 | Maintenance information | MINA HANNA | energy_progress |
| 04/01/2025 | Fenestration air leakage | MINA HANNA | energy_progress |
| 04/01/2025 | Lighting controls | MINA HANNA | energy_progress |
| 04/01/2025 | Air barrier - visual inspection | MINA HANNA | energy_progress |
| 04/01/2025 | Fenestration areas | MINA HANNA | energy_progress |
| 04/01/2025 | Protection of exposed foundation insulation | MINA HANNA | energy_progress |
| 04/01/2025 | Interior lighting power | MINA HANNA | energy_progress |
| 04/01/2025 | Lighting in dwelling units | MINA HANNA | energy_progress |
| 04/01/2025 | Exterior lighting power | MINA HANNA | energy_progress |