← Back
Two family brick
428 IRVING AVENUE
BROOKLYN · BIN 3077344
💬 Discuss this project
1910Year Built
2Stories
B1Building Class
R6Zoning
3,300 sfGross Floor Area
2Units
Rent Stabilized0 Open ViolationsFDNY Report ↗
Two family brick · Owner of record: 428 IRVING GROUP LLC · 1,900 sf lot · 1.74 FAR built · Flood zone X
Locations of Work
ArchitectureFire Protection
Roof2p · 3 filings · 14 docs
Floor 26p · 2 filings · 18 docs
Floor 16p · 2 filings · 18 docs
Basement8p · 2 filings · 19 docs
Sub-Basement1 filing · 3 docs
1 job · most recent 03/20/2026
Heating and Air Conditioning Systems
FiledStatusContractorScopeMake / Model / Capacity
03/20/2026Permit IssuedCLARKES EMPIRE INCHeating and Air Conditioning Systems
Heat / Cool
Midea MIDEA DLCMRAH27CAK 6 BTU · Vrf Outdoor ×12
1 job · most recent 02/21/2025
FiledStatusContractorScope
02/21/2025Signed-offA&H EXPRESS PLBG&HTG CORP34 heads
1 job · most recent 02/21/2025
Water/Sanitary
FiledStatusContractorScope
02/21/2025Signed-offA&H EXPRESS PLBG&HTG CORPWater/Sanitary
1 job · most recent 05/18/2026
General Wiring
FiledStatusContractorScope
05/18/2026CompleteLINTECH ELECTRIC, INCGeneral Wiring
2 jobs · most recent 02/21/2025
Steel
FiledStatusContractorScope
02/21/2025——1 scope_items
01/21/2025——Steel
Building Lifecycle
All (86)Filed (7)Permit Issued (4)Signed Off (2)Violation (1)Inspection (8)Objection (36)Special Inspection (28)
09/18/2026
Signed off — Alteration
Installation of new sprinkler system.
B01183788-I1
07/27/2026
Inspection — Certified Sprinkler-SP-Piping Dry/Wet-Hydrostatic Test
Certified
View inspection ↗
07/22/2026
Signed off — Alteration
NEW PLUMBING FIXTURES & NEW PLUMBING RISERS
B01183783-I1
05/01/2026
Inspection — Certified Sprinkler-SP-Fixtures-Finish
Certified
View inspection ↗
04/20/2026
Objection raised — Fire_Protection
04/20/2026
Objection raised — Scope
03/31/2026
Objection raised — Scope
03/20/2026
Filed — Alteration CO
INSTALLATION OF NEW PARTITION WALLS, HEATING AND COOLING SYSTEM, AND NEW KITCHEN AND BATHROOM THROUGHOUT BUILDING AS PER PLANS. CONVERT THE BUILDING FROM TWO APARTMENTS TO FIVE APARTMENTS.
B00975395-P1
03/20/2026
Special inspection requirement — Interior lighting power
MAURICIO ANDRADE
03/20/2026
Special inspection requirement — Insulation placement and R values
MAURICIO ANDRADE
03/20/2026
Special inspection requirement — HVAC-R and service water heating equipment
MAURICIO ANDRADE
03/20/2026
Special inspection requirement — Ventilation and air distribution system
MAURICIO ANDRADE
03/20/2026
Special inspection requirement — HVAC-R and service water heating system controls
MAURICIO ANDRADE
03/20/2026
Special inspection requirement — HVAC-R and service water piping design and insulation
MAURICIO ANDRADE
03/20/2026
Special inspection requirement — Fenestration air leakage
MAURICIO ANDRADE
03/20/2026
Special inspection requirement — Fenestration and door U-factor and product ratings
MAURICIO ANDRADE
03/20/2026
Special inspection requirement — Exhaust and Vent Systems in Plenums and Ducts
MAURICIO ANDRADE
03/20/2026
Special inspection requirement — Fire-Resistant Penetrations and Joints
MAURICIO ANDRADE
03/20/2026
Special inspection requirement — Mechanical Systems
MAURICIO ANDRADE
03/20/2026
Special inspection requirement — Structural Stability – Alterations of existing buildings
MAURICIO ANDRADE
03/20/2026
Special inspection requirement — Energy Code Compliance Inspections
MAURICIO ANDRADE
03/20/2026
Special inspection requirement — Final
MAURICIO ANDRADE
03/20/2026
Special inspection requirement — Fire-Resistance Rated Construction
MAURICIO ANDRADE
03/20/2026
Special inspection requirement — Fenestration areas
MAURICIO ANDRADE
03/20/2026
Special inspection requirement — Maintenance information
MAURICIO ANDRADE
03/20/2026
Special inspection requirement — Metering
MAURICIO ANDRADE
03/20/2026
Special inspection requirement — Permanent certificate
MAURICIO ANDRADE
03/20/2026
Special inspection requirement — Air barrier - visual inspection
MAURICIO ANDRADE
03/20/2026
Special inspection requirement — Duct leakage testing, insulation and design
MAURICIO ANDRADE
01/15/2026
Inspection — Certified Water and Sanitary-WS-Fixtures-Finish
Certified
View inspection ↗
09/25/2025
Inspection — Pass-Final CND-Occupancy Inspection
Pass
View inspection ↗
09/18/2025
Inspection — Fail-Final CND-Occupancy Inspection
Fail
View inspection ↗
04/07/2025
Permit issued — General Construction
B00975395-I1-GC-CX
04/04/2025
Inspection — Certified Water and Sanitary-WS-Sanitary Piping-Roughing
Certified
View inspection ↗
03/17/2025
Inspection — Certified Water and Sanitary-WS-Sanitary Piping-Underground
Certified
View inspection ↗
03/11/2025
Permit issued — Sprinklers
B01183788-I1-EW-SP
03/11/2025
Permit issued — Plumbing
B01183783-I1-PL
02/21/2025
Filed — Alteration
Installation of new sprinkler system.
B01183788-I1
02/21/2025
Filed — Alteration
NEW PLUMBING FIXTURES & NEW PLUMBING RISERS
B01183783-I1
02/21/2025
Filed — Alteration
SUPPORT OF EXCAVATION AS PER PLANS. NO CHANGE IN USE, OCCUPANCY OR EGRESS UNDER THIS APPLICATION
B01184448-I1
02/21/2025
Special inspection requirement — Fire-Resistant Penetrations and Joints
MAURICIO ANDRADE
02/21/2025
Special inspection requirement — Excavations - Sheeting, Shoring, and Bracing
MAURICIO ANDRADE
02/19/2025
Special inspection requirement — Sprinkler Systems
MAURICIO ANDRADE
02/07/2025
Objection resolved — Addressed
01/31/2025
Objection raised — Zoning
01/29/2025
Objection raised — Other
01/29/2025
Objection resolved — Addressed
01/29/2025
Objection raised — Other
01/29/2025
Objection resolved — Addressed
01/23/2025
Objection raised — Other
01/23/2025
Objection resolved — Addressed
01/23/2025
Objection raised — Other
01/23/2025
Objection resolved — Addressed
01/23/2025
Objection raised — Other
01/23/2025
Objection resolved — Addressed
01/23/2025
Objection raised — Other
01/23/2025
Objection resolved — Addressed
01/23/2025
Objection raised — Other
01/23/2025
Objection resolved — Addressed
01/21/2025
Filed — Alteration
ADDITION OF A NEW BULKHEAD AT THE ROOF OF THE EXISTING BUILDING. APPLICATION IS FILED IN CONJUNCTION WITH APPLICATION NUMBER B00975395-I1.
B01168569-I1
Latest 60 of 86 events.
▾Owner History (Filing Record)
Companies and organizations named on filings. Individual owners are not shown.
OwnerFilingsMost Recent
SELECT OR ENTER1209/13/2026
▾Sales History (ACRIS)
DatePriceUnitSeller → Buyer$/sf
10/10/2023$1.1M—— → —$348/sf building
▾Design Consultants (Architect / Engineer of Record)
FirmFilingsMost Recent
CPENGINEERING PC503/20/2026
NS ENGINEERS, P.C.201/21/2025
▾Filing Representatives (Expediters)
RepresentativeFilingsMost Recent
STEWART ENGINEERING SERVICES603/21/2026
CASA GROUP603/21/2026
▾Contractors (License-Anchored)
FirmTradeRolesMost Recent
JOHN PETTISGeneral Contractor203/21/2026
DEPENDABLE MECHANICAL CORFire Protection106/28/2026
CLARKES EMPIRE INCGeneral Contractor104/09/2026
A&H EXPRESS PLBG&HTG CORPPlumbing107/08/2026
▾Special Inspection Agencies
AgencyLicense #FilingsMost Recent
PSI AGENCY INC.254403/20/2026
SHAHRISH SHUVO ENGINEERIN8524101/05/2024
Permit / Filing Register
SourceWork TypeStatusApplicantIssued
DOB NOWGeneral ConstructionPermit IssuedCLARKES EMPIRE04/07/2025
DOB NOWSprinklersSigned-offDEPENDABLE MECHANICAL COR03/11/2025
DOB NOWPlumbingSigned-offA&H EXPRESS PLBG&HTG CORP03/11/2025
DOB NOWGeneral ConstructionPermit IssuedJOHN PETTIS11/24/2023
▾Field Inspections (DOB CAP) — 8
DateTypeResultReport
07/27/2026Certified Sprinkler-SP-Piping Dry/Wet-Hydrostatic TestCertifiedView ↗
05/01/2026Certified Sprinkler-SP-Fixtures-FinishCertifiedView ↗
01/15/2026Certified Water and Sanitary-WS-Fixtures-FinishCertifiedView ↗
09/25/2025Pass-Final CND-Occupancy InspectionPassView ↗
09/18/2025Fail-Final CND-Occupancy InspectionFailView ↗
04/04/2025Certified Water and Sanitary-WS-Sanitary Piping-RoughingCertifiedView ↗
03/17/2025Certified Water and Sanitary-WS-Sanitary Piping-UndergroundCertifiedView ↗
08/09/2024Fail-Final General Construction Non-Directive 14FailView ↗
▾Special Inspection Requirements (DOB NOW) — 28
DateRequirementInspectorRole
03/20/2026Interior lighting powerMAURICIO ANDRADEenergy_progress
03/20/2026Insulation placement and R valuesMAURICIO ANDRADEenergy_progress
03/20/2026HVAC-R and service water heating equipmentMAURICIO ANDRADEenergy_progress
03/20/2026Ventilation and air distribution systemMAURICIO ANDRADEenergy_progress
03/20/2026HVAC-R and service water heating system controlsMAURICIO ANDRADEenergy_progress
03/20/2026HVAC-R and service water piping design and insulationMAURICIO ANDRADEenergy_progress
03/20/2026Fenestration air leakageMAURICIO ANDRADEenergy_progress
03/20/2026Fenestration and door U-factor and product ratingsMAURICIO ANDRADEenergy_progress
03/20/2026Exhaust and Vent Systems in Plenums and DuctsMAURICIO ANDRADEspecial
03/20/2026Fire-Resistant Penetrations and JointsMAURICIO ANDRADEspecial
03/20/2026Mechanical SystemsMAURICIO ANDRADEspecial
03/20/2026Structural Stability – Alterations of existing buildingsMAURICIO ANDRADEspecial
03/20/2026Energy Code Compliance InspectionsMAURICIO ANDRADEprogress
03/20/2026FinalMAURICIO ANDRADEprogress
03/20/2026Fire-Resistance Rated ConstructionMAURICIO ANDRADEprogress
03/20/2026Fenestration areasMAURICIO ANDRADEenergy_progress
03/20/2026Maintenance informationMAURICIO ANDRADEenergy_progress
03/20/2026MeteringMAURICIO ANDRADEenergy_progress
03/20/2026Permanent certificateMAURICIO ANDRADEenergy_progress
03/20/2026Air barrier - visual inspectionMAURICIO ANDRADEenergy_progress
03/20/2026Duct leakage testing, insulation and designMAURICIO ANDRADEenergy_progress
02/21/2025Fire-Resistant Penetrations and JointsMAURICIO ANDRADEspecial
02/21/2025Excavations - Sheeting, Shoring, and BracingMAURICIO ANDRADEspecial
02/19/2025Sprinkler SystemsMAURICIO ANDRADEspecial
01/17/2025Final—progress
Latest 25 of 28.
▾Documents — 34 on file (BIS + DOB NOW)
▸Plans & Drawings6
▸DOB NOWPlans/Sketch6
08/22/2026B01184448-I1Request digital key ↗
08/22/2026B01183783-I1Request digital key ↗
08/22/2026B01183788-I1Request digital key ↗
Showing 3 of 6 on file for this type
▸Zoning, Tax Lot & Property Records1
▸DOB NOWZD1: DOB Zoning Diagram1
08/13/2026B01168569-I1Open ↗
▸Seals & Professional Certifications12
▸DOB NOWDPL-1: Design Professional Seal & Signature8
08/22/2026B01184448-I1Open ↗
08/22/2026B01183783-I1Open ↗
08/17/2026B00975395-I1Open ↗
Showing 3 of 8 on file for this type
▸DOB NOWSpecial Inspector Seal & Signature2
08/27/2026B00975395-P1Open ↗
08/23/2026B01183788-I1Open ↗
▸DOB NOWProgress Inspector Seal & Signature2
08/27/2026B00975395-P1Open ↗
08/27/2026B00975395-P1Open ↗
▸Safety & Tenant Protection2
▸DOB NOWStreet Tree Checklist2
08/17/2026B00975395-P1Open ↗
08/13/2026B00975395-I1Open ↗
▸Environmental & Asbestos7
▸DOB NOWDEP ACP-5: Asbestos Assessment Report7
08/22/2026B01184448-I1Open ↗
08/22/2026B01183783-I1Open ↗
08/17/2026B00975395-P1Open ↗
Showing 3 of 7 on file for this type
▸Other Documents6
▸DOB NOWProperty Ownership Certification2
08/17/2026B00975395-P1Open ↗
08/13/2026B00975395-I1Open ↗
▸DOB NOWSite Survey: Initial1
08/13/2026B01168569-I1Open ↗
▸DOB NOWLocal Law 92/94 of 2019 Sustainable Roof Zone1
08/13/2026B01168569-I1Open ↗
▸DOB NOWPlot Diagram1
08/13/2026B01168569-I1Open ↗
▸DOB NOWFinal Survey1
08/13/2026B00975395-I1Open ↗