| Owner | Filings | Most Recent |
|---|---|---|
| EMBA HOLDINGS | 2 | 03/21/2026 |
| Firm | Filings | Most Recent |
|---|---|---|
| ROGERS CALVANICO GROUP PLLC | 5 | 10/08/2024 |
| Representative | Filings | Most Recent |
|---|---|---|
| ROGERS CALVANICO GROUP | 2 | 03/21/2026 |
| Firm | Trade | Roles | Most Recent |
|---|---|---|---|
| SORRENTINO DEVELOPMENT | General Contractor | 8 | 04/09/2026 |
| FIVE BOROUGH NYC LLC | Fire Protection | 2 | 07/08/2026 |
| CHARLES J. DEHART JR P&H | Plumbing | 1 | 07/08/2026 |
| RELIABLE PLBG & HTG CORP | Plumbing | 1 | 07/08/2026 |
| Agency | License # | Filings | Most Recent |
|---|---|---|---|
| A TECH ENGINEERING NYC, P | 6738 | 3 | 08/09/2024 |
| Source | Work Type | Status | Applicant | Issued |
|---|---|---|---|---|
| DOB NOW | Sprinklers | Permit Issued | FIVE BOROUGH NYC LLC | 01/08/2026 |
| DOB NOW | General Construction | Permit Issued | SORRENTINO DEVELOPMENT | 01/02/2026 |
| DOB NOW | Mechanical Systems | Permit Issued | SORRENTINO DEVELOPMENT | 12/31/2025 |
| DOB NOW | Construction Fence | Permit Issued | SORRENTINO DEVELOPMENT | 12/19/2025 |
| DOB NOW | Plumbing | Permit Issued | CHARLES J. DEHART JR P&H | 10/28/2025 |
| DOB NOW | Sprinklers | Permit Issued | FIVE BOROUGH NYC LLC | 02/06/2025 |
| DOB NOW | Plumbing | Permit Issued | RELIABLE PLBG & HTG CORP | 02/06/2025 |
| DOB NOW | Mechanical Systems | Permit Issued | SORRENTINO DEVELOPMENT | 01/23/2025 |
| DOB NOW | Foundation | Permit Issued | SORRENTINO DEVELOPMENT | 01/22/2025 |
| DOB NOW | Construction Fence | Permit Issued | SORRENTINO DEVELOPMENT | 10/31/2024 |
| Filed | Status | Contractor | Scope | Make / Model / Capacity |
|---|---|---|---|---|
| 08/19/2024 | Permit Issued | SORRENTINO DEVELOPMENT | Air Conditioning Systems, Heating and Air Conditioning Systems, Heating Systems, Ventilation Systems | Cooling Fujitsu ASUH09LMAS/ AOUH09LMAH1 9,000 BTU · Split System ×1 Heat / Cool Fujitsu ARU30RGLX / AOU30RGLX 30,000 BTU · Heat Pump Outdoor ×5 (1) ASU00LPAS / (2) 18RLXFZH 18,000 BTU · Heat Pump Outdoor ×3 (1) ASUH00LPAS / (2) 18RLXFZH 18,000 BTU · Heat Pump Outdoor ×3 ARU36RGLX / AOU36RGLX 36,000 BTU · Heat Pump Outdoor ×2 ARU36RGLX/AOU36RGLX 36,000 BTU · Heat Pump Outdoor ×2 ARU48RGLX / AOU48RGLX 48,000 BTU · Heat Pump Outdoor ×2 ARU24RGLX/AOU24RGLX 24,000 BTU · Heat Pump Outdoor ×1 Heating Markel E2903-24-C 1,279 BTU · Electric Heater ×7 H3052T2DWB 5,119 BTU · Unit Heater ×3 E-2903-38-C 1,706 BTU · Electric Heater ×2 Modine PTC-55 55,000 BTU · Unit Heater ×5 Neptronic DF C100H 27,304 BTU · Electric Heater ×1 Ventilation Renewaire HE 2XRT 1,380 CFM · Erv ×1 |
| Filed | Status | Contractor | Scope |
|---|---|---|---|
| 08/19/2024 | Permit Issued | RELIABLE PLBG & HTG CORP | Gas, Storm, Water/Sanitary |
| Filed | Status | Contractor | Scope |
|---|---|---|---|
| 12/17/2025 | Permit Issued | K-10 ELECTRIC CORP | General Wiring |
| Filed | Status | Contractor | Scope |
|---|---|---|---|
| 08/19/2024 | Permit Issued | FIVE BOROUGH NYC LLC | Steel, Masonry |
| Date | Requirement | Inspector | Role |
|---|---|---|---|
| 08/06/2024 | Maintenance information | anthony santoro | energy_progress |
| 08/06/2024 | HVAC-R and service water heating system controls | anthony santoro | energy_progress |
| 08/06/2024 | HVAC-R and service water piping design and insulation | anthony santoro | energy_progress |
| 08/06/2024 | HVAC-R and service water heating equipment | anthony santoro | energy_progress |
| 07/17/2024 | HVAC-R and service water heating equipment | anthony santoro | energy_progress |
| 07/17/2024 | Energy Code Compliance Inspections | anthony santoro | progress |
| 07/17/2024 | HVAC-R and service water heating system controls | anthony santoro | energy_progress |
| 07/17/2024 | Maintenance information | anthony santoro | energy_progress |
| 07/17/2024 | HVAC-R and service water piping design and insulation | anthony santoro | energy_progress |
| 07/17/2024 | Shutoff dampers | anthony santoro | energy_progress |
| 05/31/2024 | Final | anthony santoro | progress |
| 05/31/2024 | Mechanical Systems | anthony santoro | special |
| 05/28/2024 | Air barrier - visual inspection | anthony santoro | energy_progress |
| 08/24/2023 | Final | anthony santoro | progress |
| 08/24/2023 | Footing and Foundation | anthony santoro | progress |
| 08/24/2023 | Energy Code Compliance Inspections | anthony santoro | progress |
| 08/24/2023 | Fire-Resistance Rated Construction | anthony santoro | progress |
| 08/24/2023 | Exterior lighting power | anthony santoro | energy_progress |
| 08/24/2023 | Air barrier — testing | anthony santoro | energy_progress |
| 08/24/2023 | Fenestration air leakage | anthony santoro | energy_progress |
| 08/24/2023 | Fenestration areas | anthony santoro | energy_progress |
| 08/24/2023 | Lighting controls | anthony santoro | energy_progress |
| 08/24/2023 | Air barrier continuity plan testing | anthony santoro | energy_progress |
| 08/24/2023 | Fenestration and door U-factor and product ratings | anthony santoro | energy_progress |
| 08/24/2023 | Maintenance information | anthony santoro | energy_progress |