← Back
Elevator apt, fireproof with stores
425 3 AVENUE
MANHATTAN · Murray Hill-Kips Bay · BIN 1019945
💬 Discuss this project
1967Year Built
9Stories
D6Building Class
C2-8Zoning
66,403 sfGross Floor Area
105Units
LL97 CoveredRent Stabilized48 Open Violations ▸FISP: SWARMP
Elevator apt, fireproof with stores · Owner of record: WOODYCREST REALTY OWNER LLC · 8,147 sf lot · 8.15 FAR built · Flood zone X
Locations of Work
ArchitectureStructuralElectricalMechanicalPlumbingEquipment
Permit Issued — active, not yet Signed-off
RoofUnder Construction2p · 2 filings · 9 docs
Floor 1Under Construction34p · 5 filings · 20 docs
Cellar29p · 4 filings · 20 docs
Site & exterior2p · 3 filings · 7 docs
▾Owner History (Filing Record)
Companies and organizations named on filings. Individual owners are not shown.
OwnerFilingsMost Recent
ZKW ENTERPRISES209/30/2026
WOODYCREST REALTY OWNER LLC103/22/2026
BENCHMARK 425 LP403/22/2026
200 REALTY LLC2003/22/2026
BENCHMARK REAL ESTATE203/22/2026
BENCHMARK 425L.P C/O BENC103/22/2026
425 3ND AVE REALTY CO503/22/2026
425 THIRD AVE REALTY CO1803/22/2026
CENTRAL CONSTRUCTION103/22/2026
MAYER HAUSER REALTY IN1503/22/2026
▾Sales History (ACRIS)
DatePriceUnitSeller → Buyer$/sf
02/10/2015$68.2M—— → —$1,028/sf building
▾Design Consultants (Architect / Engineer of Record)
FirmFilingsMost Recent
IKRA CONSULTING LLC106/25/2026
2L ENGINEERING, DPC504/12/2024
STUDIO HUJI302/08/2024
WID CHAPMAN ARCHITECTS111/13/2023
NEW YORK ENGINEERING ASSOC., P.C.108/19/2022
DARIO PASQUARIELLO ARCHITECT108/20/2020
JAMES H. FAHEY109/30/2019
▾Filing Representatives (Expediters)
RepresentativeFilingsMost Recent
LOUIS STRIAR603/21/2026
A1 EXPEDITING SERVICE CORP.1203/21/2026
NEW YORK ENGINEERING ASSOCIATES P203/21/2026
DJL ARCHITECT103/21/2026
CONSTRUCTION PERMIT SERVICES203/21/2026
▾Contractors (License-Anchored)
FirmTradeRolesMost Recent
EXCLUSIVE RESTORATION &General Contractor407/08/2026
ACTIVE SIGNSScaffold307/08/2026
ZKW ENTERPRISES INCGeneral Contractor209/30/2026
CROCITTO, JR., WILLIAMElectrical103/21/2026
HINKE, WILLIAMElectrical103/21/2026
JACKUS, STEVEElectrical103/21/2026
LAMMY, MICHAELElectrical103/21/2026
MAGALLANES, ROBERTOElectrical103/21/2026
MARTIN, CLINTElectrical103/21/2026
MOHAMED ABDOUElectrical103/21/2026
ABDOU MOHAMEDElectrical103/21/2026
ROBERT CHIMENTIElectrical103/21/2026
ROBERT CHIMENTIElectrical103/22/2026
ROBERT COVELLOElectrical103/21/2026
TELCOM ENGINEERING GP INCGeneral Contractor107/08/2026
AQUA PLUMBING & HTNG CORPPlumbing107/08/2026
CROWN PLUMBING INCPlumbing107/08/2026
M&T ELECTRICAL LLCElectrical103/22/2026
BOHLINGER, BElectrical103/21/2026
COUNTY ELECL CONTRACTOR IElectrical103/22/2026
▾Special Inspection Agencies
AgencyLicense #FilingsMost Recent
GEORGE J. XERAKIAS, PE1658107/17/2026
MILROSE CONSULTANTS LLC2003604/12/2024
NEW YORK ENGINEERING ASSO851108/19/2022
DARIO ARCHITECTURE &DESIG6878108/20/2020
STRUCTURAL CONSULTING SER1919109/30/2019
Building Lifecycle
All (148)Filed (14)Permit Issued (12)Signed Off (6)Facade (FISP) (15)Violation (60)Inspection (8)Objection (14)Special Inspection (19)
09/29/2026
Permit issued — Sidewalk Shed
M01421510-I1-SH
08/17/2026
Permit issued — Suspended Scaffold
M01432203-I1-SC
08/12/2026
Objection resolved — Addressed
07/29/2026
Objection raised — Other
07/29/2026
Objection resolved — Addressed
07/28/2026
Objection raised — Other
07/17/2026
Filed — Alteration
Installation of suspended scaffold for facade repair & inspection.
M01432203-I1
07/16/2026
Special inspection requirement — Post-installed Anchors
George Xerakias
07/16/2026
Special inspection requirement — Alternative Materials - OTCR Buildings Bulletin Number
George Xerakias
07/16/2026
Special inspection requirement — Post-installed anchors in masonry
George Xerakias
06/29/2026
Permit issued — Sidewalk Shed
M01421510-I1-SH
06/25/2026
Filed — Alteration
INSTALLATION OF 300PSF SIDEWALK SHED AS PER PLANS. ALL EQUIPMENT SHALL COMPLY WITH CH #33 OF THE NYC CODE 2022. NO CHANGE IN USE, OCCUPANCY OR EGRESS UNDER THIS APPLICATION.
M01421510-I1
01/08/2026
Violation issued (HPD, open)
A
01/08/2026
Violation issued (HPD, open)
B
01/08/2026
Violation issued (HPD, open)
B
01/08/2026
Violation issued (HPD, open)
A
01/08/2026
Violation issued (HPD, open)
A
01/08/2026
Violation issued (HPD, open)
A
01/08/2026
Violation issued (HPD, open)
B
01/08/2026
Violation issued (HPD, open)
B
01/08/2026
Violation issued (HPD, open)
B
01/08/2026
Violation issued (HPD, open)
B
01/08/2026
Violation issued (HPD, open)
B
01/08/2026
Violation issued (HPD, closed)
C
07/15/2025
Violation issued (HPD, open)
A
06/26/2025
Inspection — Certified Storm Drainage-ST-Fixtures-Finish
Certified
View inspection ↗
06/26/2025
Inspection — Certified Water and Sanitary-WS-Fixtures-Finish
Certified
View inspection ↗
08/20/2024
Signed off — Alteration
Removal and renovation of non-load bearing partitions as per plans filed herewith. No change in use, egress or occupancy.
M00945096-I1
04/12/2024
Filed — Alteration
Modification to existing Plumbing scope and fixtures as per plans filed herewith. Installation of new kitchen fixtures. No change in use, egress or occupancy under this application.
M00949258-P2
04/12/2024
Special inspection requirement — Fire-Resistant Penetrations and Joints
Christopher Drutjons
04/12/2024
Special inspection requirement — Tenant Protection Plan Compliance
Christopher Drutjons
04/11/2024
Inspection — Pass-Final PL - Up to 3 Requested Floors
Pass
View inspection ↗
04/03/2024
Inspection — Certified Sprinkler (PL)-Sprinkler-Hydro
Certified
View inspection ↗
04/03/2024
Inspection — Certified Water and Sanitary-WS-Fixtures-Finish
Certified
View inspection ↗
04/02/2024
Violation issued (HPD, closed)
C
04/02/2024
Inspection — Pass-Final PL - Up to 3 Requested Floors
Pass
View inspection ↗
03/26/2024
Filed — Alteration
Modification to existing Plumbing scope and fixtures as per plans filed herewith. Installation of new kitchen fixtures. No change in use, egress or occupancy under this application.
M00949258-P1
03/21/2024
Signed off — Alteration
M01000727-I1
03/21/2024
Signed off — Alteration
ILLUMINATED NON-ADVERTISING ACCESSORY SIGN ON EXISTING STOREFRONT FASCIA SIGN BAND - H&H BAGELS. NO CHANGE OF USE, EGRESS OR OCCUPANCY.
M01000728-I1
03/21/2024
Signed off — Alteration
ILLUMINATED NON-ADVERTISING ACCESSORY SIGN ON EXISTING STOREFRONT FASCIA SIGN BAND - H&H BAGELS. NO CHANGE OF USE, EGRESS OR OCCUPANCY.
M01000726-I1
03/14/2024
Special inspection requirement — Final
Christopher Drutjons
03/14/2024
Special inspection requirement — Post-installed Anchors
Christopher Drutjons
03/14/2024
Special inspection requirement — Mechanical Systems
Christopher Drutjons
03/14/2024
Special inspection requirement — Tenant Protection Plan Compliance
Christopher Drutjons
03/05/2024
Filed — Alteration
Modification to existing HVAC system and including commercial kitchen range-hood ventilation system. New ductwork only. No change in use, egress or occupancy.
M00948744-P1
03/01/2024
Special inspection requirement — Mechanical Systems
Christopher Drutjons
03/01/2024
Special inspection requirement — Post-installed Anchors
Christopher Drutjons
03/01/2024
Special inspection requirement — Tenant Protection Plan Compliance
03/01/2024
Special inspection requirement — Final
Christopher Drutjons
02/20/2024
Permit issued — Sign
M01000727-I1-SG
02/20/2024
Permit issued — Sign
M01000728-I1-SG
02/20/2024
Permit issued — Sign
M01000726-I1-SG
02/12/2024
Inspection — Pass-Final PL - Up to 3 Requested Floors
Pass
View inspection ↗
02/08/2024
Filed — Alteration
M01000727-I1
02/08/2024
Filed — Alteration
ILLUMINATED NON-ADVERTISING ACCESSORY SIGN ON EXISTING STOREFRONT FASCIA SIGN BAND - H&H BAGELS. NO CHANGE OF USE, EGRESS OR OCCUPANCY.
M01000728-I1
02/08/2024
Filed — Alteration
ILLUMINATED NON-ADVERTISING ACCESSORY SIGN ON EXISTING STOREFRONT FASCIA SIGN BAND - H&H BAGELS. NO CHANGE OF USE, EGRESS OR OCCUPANCY.
M01000726-I1
02/08/2024
Special inspection requirement — Final
Ryan Hung
01/05/2024
Permit issued — General Construction
M00945096-I1-GC
12/20/2023
Permit issued — Mechanical Systems
M00948744-I1-MS
12/19/2023
Permit issued — Plumbing
M00949258-I1-PL
Latest 60 of 148 events.
Permit / Filing Register
SourceWork TypeStatusApplicantIssued
DOB NOWSidewalk ShedPermit IssuedZKW ENTERPRISES INC09/29/2026
DOB NOWSuspended ScaffoldPermit IssuedRAPID MASONRY REST. CORP08/17/2026
DOB NOWSidewalk ShedPermit IssuedZKW ENTERPRISES INC06/29/2026
DOB NOWSignSigned-offACTIVE SIGNS INC02/20/2024
DOB NOWSignSigned-offACTIVE SIGNS INC02/20/2024
DOB NOWSignSigned-offACTIVE SIGNS INC02/20/2024
DOB NOWGeneral ConstructionSigned-offEXCLUSIVE RESTORATION &01/05/2024
DOB NOWMechanical SystemsPermit IssuedEXCLUSIVE RESTORATION &12/20/2023
DOB NOWPlumbingPermit IssuedAQUA PLUMBING & HTNG CORP12/19/2023
DOB NOWBoiler EquipmentSigned-offG. BAUER, INC10/26/2022
DOB NOWPlumbingPermit IssuedCROWN PLUMBING INC08/31/2020
DOB NOWAntennaSigned-offLINED UP CONSTRUCTION12/05/2019
BISOTISSUEDSAT CONSTRUCTION SERVICES08/20/2020
BISPLISSUEDAP PLUMBING & HVAC LLC03/20/2019
BISOTISSUEDEURO GROUP DESIGN GROUP03/11/2019
BISPLISSUEDP.S.I. MECHANICAL07/03/2018
BISOTISSUEDE & D GENERAL CONTRACTOR05/19/2017
BISPLISSUEDPETER PLUMBING ASSOC. INC.08/04/2016
BISMHISSUEDH&K NY CORP07/22/2016
BISPLISSUEDBAUER MECHANCIAL LLC02/23/2016
BISOTISSUEDSQUAN CONSTRUCTION SERVIC10/01/2015
BISOTISSUEDTELCOM ENGINEERING GP INC04/22/2015
BISOTISSUEDTGI BUILDERS INC11/18/2013
BISOTISSUEDBUILT FOR HEALTH LTD10/11/2013
BISPLISSUEDALJER PLBG & HTG CORP09/12/2013
BISOTISSUEDBUILT FOR HEALTH LTD09/05/2013
BISOTISSUEDTELCOM ENGINEERING GP INC08/08/2013
BISPLISSUEDALJER PLBG & HTG CORP07/24/2013
BISOTISSUEDBUILT FOR HEALTH LTD07/18/2013
BISOTISSUEDRC3 ELECTRIC, LLC07/05/2013
BISOTISSUEDSHKODER CONTRACTING CORP06/28/2013
BISEQISSUEDSHKODER CONTRACTING CORP06/28/2013
BISPLISSUEDALJER PLBG & HTG CORP06/12/2013
BISOTISSUEDBUILT FOR HEALTH LLC06/11/2013
BISOTISSUEDBUILT FOR HEALTH LLC06/11/2013
BISOTISSUEDBUILT FOR HEALTH LLC06/03/2013
BIS—ISSUEDJOHN CAPPELLI ERECTORS IN05/22/2013
BISPLISSUEDALJER PLBG & HTG CORP03/18/2013
BISOTISSUEDBUILT FOR HEALTH LLC01/31/2013
BISPLISSUEDALJER PLBG & HTG CORP12/12/2012
+ 22 more permits on file
1 project · most recent 03/05/2024
Refrigeration Systems
FiledStatusContractorScopeMake / Model / Capacity
03/05/2024Permit IssuedEXCLUSIVE RESTORATION &Refrigeration Systems
Refrigeration
— Norlake KL-10 6,700 BTU · Refrigeration Unit ×2
1 project · most recent 04/12/2024
FiledStatusContractorScope
04/12/2024——2 heads
2 projects · most recent 04/12/2024
Water/Sanitary Gas Plumbing-Sprinkler
FiledStatusContractorScope
04/12/2024Permit IssuedAQUA PLUMBING & HTNG CORPGas, Plumbing-Sprinkler, Water/Sanitary
08/20/2020Permit IssuedCROWN PLUMBING INCWater/Sanitary
5 projects · most recent 06/29/2026
General Wiring Boiler Controls
FiledStatusContractorScope
06/29/2026Permit IssuedRICHARD NEU—
05/15/2026CompleteCOUNTY ELECL CONTRACTOR IBoiler Controls
09/10/2025CompleteROBERT CHIMENTI74 meters, 1 new_meters
03/28/2024Permit IssuedM&T ELECTRICAL LLCGeneral Wiring
07/28/2020Permit IssuedMARTINEZ ELECTRICAL CONTGeneral Wiring
1 project · most recent 06/25/2026
Sidewalk Shed
FiledStatusContractorScope
06/25/2026Permit IssuedZKW ENTERPRISES INCSidewalk Shed
1 project · most recent 07/17/2026
Suspended Scaffold (SC)
FiledStatusContractorScope
07/17/2026Permit IssuedRAPID MASONRY REST. CORPSuspended Scaffold (SC)
▾Field Inspections (DOB CAP) — 8
DateTypeResultReport
06/26/2025Certified Storm Drainage-ST-Fixtures-FinishCertifiedView ↗
06/26/2025Certified Water and Sanitary-WS-Fixtures-FinishCertifiedView ↗
04/11/2024Pass-Final PL - Up to 3 Requested FloorsPassView ↗
04/03/2024Certified Sprinkler (PL)-Sprinkler-HydroCertifiedView ↗
04/03/2024Certified Water and Sanitary-WS-Fixtures-FinishCertifiedView ↗
04/02/2024Pass-Final PL - Up to 3 Requested FloorsPassView ↗
02/12/2024Pass-Final PL - Up to 3 Requested FloorsPassView ↗
04/04/2023Pass-Final Boiler Equipment InspectionPassView ↗
▾Special Inspection Requirements (DOB NOW) — 19
DateRequirementInspectorRole
07/16/2026Post-installed AnchorsGeorge Xerakiasspecial
07/16/2026Alternative Materials - OTCR Buildings Bulletin NumberGeorge Xerakiasspecial
07/16/2026Post-installed anchors in masonryGeorge Xerakiasspecial
04/12/2024Fire-Resistant Penetrations and JointsChristopher Drutjonsspecial
04/12/2024Tenant Protection Plan ComplianceChristopher Drutjonsspecial
03/14/2024FinalChristopher Drutjonsprogress
03/14/2024Post-installed AnchorsChristopher Drutjonsspecial
03/14/2024Mechanical SystemsChristopher Drutjonsspecial
03/14/2024Tenant Protection Plan ComplianceChristopher Drutjonsspecial
03/01/2024Mechanical SystemsChristopher Drutjonsspecial
03/01/2024Post-installed AnchorsChristopher Drutjonsspecial
03/01/2024Tenant Protection Plan Compliance—special
03/01/2024FinalChristopher Drutjonsprogress
02/08/2024FinalRyan Hungprogress
11/09/2023Fire-Resistant Penetrations and JointsChristopher Drutjonsspecial
11/06/2023Tenant Protection Plan ComplianceChristopher Drutjonsspecial
11/02/2023FinalChristopher Drutjonsprogress
05/26/2022Heating SystemsLOUIS ARENAspecial
08/20/2020Fire-Resistant Penetrations and JointsDario Pasquariellospecial
▾Documents — 426 on file (BIS + DOB NOW)
▸Plans & Drawings15
▸DOB NOWPlans/Sketch12
09/02/2026M00746579-I1Request digital key ↗
08/28/2026M00945096-I1Request digital key ↗
08/28/2026M01000728-I1Request digital key ↗
Showing 3 of 12 on file for this type
▸DOB NOWPlans/Sketch - Plumbing2
09/04/2026M00388028-I1Request digital key ↗
08/15/2026M00388028-P1Request digital key ↗
▸DOB NOWPlans/Sketch - Antenna1
08/15/2026M00168875-I1Request digital key ↗
▸Applications & Permits84
▸BISPLAN / WORK APPROVAL APPLICATION44
10/26/2020140941578Open ↗
10/16/2020140941578Open ↗
08/19/2020140941578Open ↗
Showing 3 of 44 on file for this type
▸BISWORK PERMIT APPLICATION40
08/20/2020140941578Open ↗
03/25/2019123446609Open ↗
03/11/2019123446609Open ↗
Showing 3 of 40 on file for this type
▸Seals & Professional Certifications86
▸BISTECHNICAL REPORT: RESPONSIBILITY/CERTIFICATION31
05/31/2019123446609Open ↗
05/31/2019123446609Open ↗
09/17/2018122363833Open ↗
Showing 3 of 31 on file for this type
▸DOB NOWDPL-1: Design Professional Seal & Signature14
09/04/2026M00388028-I1Open ↗
08/28/2026M00945096-I1Open ↗
08/28/2026M01000727-I1Open ↗
Showing 3 of 14 on file for this type
▸DOB NOWSpecial Inspector Seal & Signature11
09/23/2026M00746579-I1Open ↗
09/01/2026M00948744-I1Open ↗
09/01/2026M00948744-I1Open ↗
Showing 3 of 11 on file for this type
▸BISPROFESSIONAL CERTIFIED CHECKLIST10
07/28/2016122734238Open ↗
09/11/2013121770208Open ↗
Showing 2 of 10 on file for this type
▸BISPROFESSIONAL CERTIFICATION STATEMENT FORM9
09/11/2013121770208Open ↗
Showing 1 of 9 on file for this type
▸DOB NOWProgress Inspector Seal & Signature4
09/01/2026M00948744-I1Open ↗
08/31/2026M01000728-I1Open ↗
08/28/2026M00948744-P1Open ↗
Showing 3 of 4 on file for this type
▸BISPROFESSIONAL CERTIFICATION STATEMENT3
08/19/2020140941578Open ↗
07/28/2016122734238Open ↗
02/22/2016140460980Open ↗
▸BISREQUIRED ITEMS CHECKLIST FOR PROFESSIONAL CERTIFICATION2
08/19/2020140941578Open ↗
02/22/2016140460980Open ↗
▸BISTECHNICAL REPORT STATEMENT OF RESPONSIBILITY2
08/19/2020140941578Open ↗
02/22/2016140460980Open ↗
▸Trade Schedules & Equipment38
▸BISSELF-CERT PLUMBING NOTICE18
05/15/2014121808160Open ↗
03/31/2014121808160Open ↗
03/26/2014121808160Open ↗
Showing 3 of 18 on file for this type
▸BISSCHEDULE B - PLUMBING14
02/22/2016140460980Open ↗
12/18/2013121808160Open ↗
11/15/2013121808160Open ↗
Showing 3 of 14 on file for this type
▸BISSCHEDULE B - PLUMBING/SPRINKLER/STANDPIPE5
11/29/2018123446609Open ↗
04/26/2017123042778Open ↗
07/28/2016122734238Open ↗
Showing 3 of 5 on file for this type
▸BISFA - FDNY APPROVAL : FD-FAA1
05/06/2015122251053Open ↗
▸Safety & Tenant Protection9
▸BISTenant Protection Plan and Notes5
01/25/2019123446609Open ↗
07/17/2018122363833Open ↗
04/26/2017123042778Open ↗
Showing 3 of 5 on file for this type
▸BISSTREET TREE CHECKLIST2
11/29/2018123446609Open ↗
Showing 1 of 2 on file for this type
▸DOB NOWTenant Protection Plan2
09/04/2026M00388028-I1Open ↗
08/13/2026M00388028-P1Open ↗
▸Environmental & Asbestos27
▸BISASBESTOS: CERTIFICATION (DEP ACP5)13
08/19/2020140941578Open ↗
11/29/2018123446609Open ↗
04/26/2017123042778Open ↗
Showing 3 of 13 on file for this type
▸DOB NOWDEP ACP-5: Asbestos Assessment Report10
09/04/2026M00388028-I1Open ↗
08/28/2026M00945096-I1Open ↗
08/27/2026M00948744-P1Open ↗
Showing 3 of 10 on file for this type
▸BISTHIS IS 'NOT AN ASBESTOS PROJECT'4
On file, but not among the 200 most recently loaded documents for this source.
Showing 0 of 4 on file for this type
▸Energy Compliance39
▸BISTECHNICAL REPORT: ENERGY CODE PROGRESS INSPS19
05/31/2019123446609Open ↗
05/31/2019123446609Open ↗
09/17/2018122363833Open ↗
Showing 3 of 19 on file for this type
▸BISAS-BUILT ENERGY ANALYSIS11
02/02/2021140941578Open ↗
05/31/2019123446609Open ↗
09/17/2018122363833Open ↗
Showing 3 of 11 on file for this type
▸BISTECHNICAL REPORT: ENERGY CODE - RESPONSIBILITY3
02/02/2021140941578Open ↗
08/19/2020140941578Open ↗
02/22/2016140460980Open ↗
▸BISTR8: Energy Code Progress Inspections2
06/18/2014121634785Open ↗
Showing 1 of 2 on file for this type
▸BISTECHNICAL REPORT STATEMENT OF RESPONSIBILITY FOR ENERGY CODE PROGRESS INSPECTIONS2
08/19/2020140941578Open ↗
02/22/2016140460980Open ↗
▸DOB NOWPreliminary Commissioning Report Certification1
08/13/2026M00746579-I1Open ↗
▸DOB NOWEN2: As Built Energy Analysis.1
08/13/2026M00168875-I1Open ↗
▸Inspections & Test Reports3
▸BISTECHNICAL REPORT: RESPONSIBILITY3
02/02/2021140941578Open ↗
08/19/2020140941578Open ↗
02/22/2016140460980Open ↗
▸Approvals, Objections & Sign-offs28
▸BISCERTIFICATE OF OCCUPANCY/LOC: REQUEST15
02/02/2021140941578Open ↗
05/31/2019123446609Open ↗
09/17/2018122363833Open ↗
Showing 3 of 15 on file for this type
▸BISADMINISTRATIVE OBJECTIONS10
07/28/2016122734238Open ↗
Showing 1 of 10 on file for this type
▸BISLETTERS - SUPPORTING DOCUMENTATION3
01/25/2019123446609Open ↗
Showing 1 of 3 on file for this type
▸Cost, Insurance & Ownership52
▸BISCOST AFFIDAVIT45
02/02/2021140941578Open ↗
08/19/2020140941578Open ↗
05/31/2019123446609Open ↗
Showing 3 of 45 on file for this type
▸BISHIC LICENSE OR AFFIDAVIT7
10/15/2013121808160Open ↗
09/11/2013121770208Open ↗
Showing 2 of 7 on file for this type
▸Filing & Intake Forms43
▸BISADDITIONAL INFORMATION22
07/25/2018122363833Open ↗
07/17/2018122363833Open ↗
10/16/2015122363833Open ↗
Showing 3 of 22 on file for this type
▸BISEFILING COVER SHEET15
11/29/2018123446609Open ↗
04/26/2017123042778Open ↗
07/28/2016122734238Open ↗
Showing 3 of 15 on file for this type
▸BISBOROUGH INTAKE FORM4
05/31/2019123446609Open ↗
09/17/2018122363833Open ↗
07/17/2018122363833Open ↗
Showing 3 of 4 on file for this type
▸BISEFILING JOB APPLICATION COVER SHEET2
08/19/2020140941578Open ↗
02/22/2016140460980Open ↗
▸Other Documents2
▸DOB NOWCalculations1
08/14/2026M01432203-I1Open ↗
▸DOB NOWManufacturer's Specifications1
08/14/2026M01432203-I1Open ↗