← Back
Two family converted from one family
43-20 218 STREET
QUEENS · BIN 4523816
💬 Discuss this project
1920Year Built
2.5Stories
B3Building Class
R3XZoning
1,702 sfGross Floor Area
2Units
Rent Stabilized1 Open Violation ▸FDNY Report ↗
Two family converted from one family · 5,000 sf lot · 0.34 FAR built · Flood zone X
Locations of Work
No floor-level scope or drawing coverage on file for this building.
1 job · most recent 05/20/2026
Storm
FiledStatusContractorScope
05/20/2026——Storm
1 job · most recent 05/20/2026
FiledStatusContractorScope
05/20/2026——1 scope_items
1 job · most recent 12/24/2025
Fence
FiledStatusContractorScope
12/24/2025Signed-offGOLDEN TIME CONTRACTING IFence
1 job · most recent 12/24/2025
Full Demolition Notification
FiledStatusContractorScope
12/24/2025Signed-offGOLDEN TIME CONTRACTING IFull Demolition Notification
Building Lifecycle
All (24)Filed (3)Permit Issued (2)Signed Off (1)Objection (8)Special Inspection (10)
06/15/2026
Objection resolved — Resolved
06/15/2026
Objection resolved — Addressed
06/15/2026
Objection resolved — Addressed
06/15/2026
Objection resolved — Addressed
06/11/2026
Objection raised — Scope
06/11/2026
Objection raised — Structural
06/11/2026
Objection raised — Inspections
06/11/2026
Objection raised — Energy
05/20/2026
Filed — New Building
PROPOSE A NEW ONE STORY GARAGE AT REAR YARD. OBTAIN NEW C OF O.
Q01405563-I1
05/20/2026
Special inspection requirement — Concrete - Cast-In-Place
05/20/2026
Special inspection requirement — Fire-Resistant Penetrations and Joints
05/20/2026
Special inspection requirement — Masonry
05/20/2026
Special inspection requirement — Final
05/20/2026
Special inspection requirement — Footing and Foundation
05/20/2026
Special inspection requirement — Energy Code Compliance Inspections
05/20/2026
Special inspection requirement — Fire-Resistance Rated Construction
05/20/2026
Special inspection requirement — Duct leakage testing, insulation and design
05/20/2026
Special inspection requirement — Interior lighting power
05/20/2026
Special inspection requirement — Electric vehicle service equipment requirements
04/23/2026
Signed off — Full Demolition
HAND DEMOLITION OF EXISTING ONE STORY GARAGE
Q01231780-I1
04/14/2026
Permit issued — Full Demolition
Q01231780-I1-FD
12/31/2025
Permit issued — Construction Fence
Q01231780-S2-FN
12/24/2025
Filed — Full Demolition
HAND DEMOLITION OF EXISTING ONE STORY GARAGE
Q01231780-S2
08/19/2025
Filed — Full Demolition
HAND DEMOLITION OF EXISTING ONE STORY GARAGE
Q01231780-I1
▾Sales History (ACRIS)
DatePriceUnitSeller → Buyer$/sf
02/14/2025$1.2M—Private party → Private party$729/sf building
▾Design Consultants (Architect / Engineer of Record)
FirmFilingsMost Recent
AMERILAND BROOK LLC205/20/2026
BRIAN ILL DEVELOPMENT LLC112/24/2025
▾Filing Representatives (Expediters)
RepresentativeFilingsMost Recent
AMERILAND BROOK LLC203/21/2026
▾Contractors (License-Anchored)
FirmTradeRolesMost Recent
DHC POWER MANAGEMENT CORPGeneral Contractor104/09/2026
GOLDEN TIME CONTRACTING IGeneral Contractor107/08/2026
Permit / Filing Register
SourceWork TypeStatusApplicantIssued
DOB NOWFull DemolitionSigned-offGOLDEN TIME CONTRACTING I04/14/2026
DOB NOWConstruction FenceSigned-offDHC POWER MANAGEMENT CORP12/31/2025
▾Special Inspection Requirements (DOB NOW) — 10
DateRequirementInspectorRole
05/20/2026Concrete - Cast-In-Place—special
05/20/2026Fire-Resistant Penetrations and Joints—special
05/20/2026Masonry—special
05/20/2026Final—progress
05/20/2026Footing and Foundation—progress
05/20/2026Energy Code Compliance Inspections—progress
05/20/2026Fire-Resistance Rated Construction—progress
05/20/2026Duct leakage testing, insulation and design—energy_progress
05/20/2026Interior lighting power—energy_progress
05/20/2026Electric vehicle service equipment requirements—energy_progress
▾Documents — 24 on file (BIS + DOB NOW)
▸Plans & Drawings3
▸DOB NOWPlans/Sketch3
08/18/2026Q01231780-S2Request digital key ↗
08/18/2026Q01231780-I1Request digital key ↗
08/15/2026Q01405563-I1Request digital key ↗
▸Zoning, Tax Lot & Property Records3
▸DOB NOWZD1: DOB Zoning Diagram1
08/15/2026Q01405563-I1Open ↗
▸DOB NOWHouse Number Verification: TOPO Stamp1
08/15/2026Q01405563-I1Open ↗
▸DOB NOWZoning Exhibit form (1-5)1
08/15/2026Q01405563-I1Open ↗
▸Seals & Professional Certifications3
▸DOB NOWDPL-1: Design Professional Seal & Signature3
08/18/2026Q01231780-S2Open ↗
08/18/2026Q01231780-I1Open ↗
08/16/2026Q01405563-I1Open ↗
▸Trade Schedules & Equipment5
▸DOB NOWDEP: Sewer Certification (Sanitary/Storm)1
08/15/2026Q01405563-I1Open ↗
▸DOB NOWElectric Cut-Off1
08/13/2026Q01231780-I1Open ↗
▸DOB NOWWater Cut-Off1
08/13/2026Q01231780-I1Open ↗
▸DOB NOWGas Cut-Off1
08/13/2026Q01231780-I1Open ↗
▸DOB NOWSewer Cut-Off1
08/13/2026Q01231780-I1Open ↗
▸Safety & Tenant Protection1
▸DOB NOWStreet Tree Checklist1
08/15/2026Q01405563-I1Open ↗
▸Environmental & Asbestos2
▸DOB NOWDEP ACP-5: Asbestos Assessment Report1
08/18/2026Q01231780-I1Open ↗
▸DOB NOWRodent Control1
08/13/2026Q01231780-I1Open ↗
▸Other Documents7
▸DOB NOWProperty Ownership Certification2
08/18/2026Q01231780-I1Open ↗
08/15/2026Q01405563-I1Open ↗
▸DOB NOWLocal Law 92/94 of 2019 Sustainable Roof Zone1
08/15/2026Q01405563-I1Open ↗
▸DOB NOWCommunity Board Notification1
08/13/2026Q01231780-I1Open ↗
▸DOB NOWFull Demo: 10-Day Notice1
08/13/2026Q01231780-I1Open ↗
▸DOB NOWStructure Photographs1
08/13/2026Q01231780-I1Open ↗
▸DOB NOWSite Survey: Initial1
08/15/2026Q01405563-I1Open ↗