← Back
Primarily 2 family with 1 store or office
43-70 162 STREET
QUEENS · East Flushing · BIN 4122398
💬 Discuss this project
1930Year Built
2.5Stories
S2Building Class
R5BZoning
4,039 sfGross Floor Area
3Units
0 Open ViolationsFDNY Report ↗
Primarily 2 family with 1 store or office · 4,000 sf lot · 1.01 FAR built · Flood zone X
Locations of Work
Plumbing
Cellar1p · 1 filing · 4 docs
▾Sales History (ACRIS)
DatePriceUnitSeller → Buyer$/sf
06/06/2014$1.6M—Private party → Private party$401/sf building
▾Design Consultants (Architect / Engineer of Record)
FirmFilingsMost Recent
LEE ENGINEERING, P.C.106/28/2022
▾Filing Representatives (Expediters)
RepresentativeFilingsMost Recent
LEE ENGINEERING P C203/21/2026
▾Contractors (License-Anchored)
FirmTradeRolesMost Recent
C.R.U. MECHAN & HEAT INCPlumbing107/08/2026
▾Special Inspection Agencies
AgencyLicense #FilingsMost Recent
LEE ENGINEERING, P.C.2157106/28/2022
Building Lifecycle
All (15)Filed (1)Permit Issued (1)Signed Off (1)Violation (9)Inspection (2)Special Inspection (1)
09/16/2022
Signed off — Alteration
REPAIR AND REPLACEMENT OF THE HEADER SERVICE AND IN-HOUSE GAS PIPING IN CELLAR TO RESPONSE GAS COMPANY'S RED TAG AND OBTAIN GAS AUTHORIZATIONS.**NO CHANGE IN USE, OCCUPANCY, OR EGRESS IS INVOLVED UNDER THIS APPLICATION**
Q00765058-I1
07/22/2022
Inspection — Pass-Final PL - Up to 3 Requested Floors
Pass
View inspection ↗
07/07/2022
Inspection — Certified Gas-Gas-Piping-Roughing
Certified
View inspection ↗
07/01/2022
Permit issued — Plumbing
Q00765058-I1-PL
06/28/2022
Filed — Alteration
REPAIR AND REPLACEMENT OF THE HEADER SERVICE AND IN-HOUSE GAS PIPING IN CELLAR TO RESPONSE GAS COMPANY'S RED TAG AND OBTAIN GAS AUTHORIZATIONS.**NO CHANGE IN USE, OCCUPANCY, OR EGRESS IS INVOLVED UNDER THIS APPLICATION**
Q00765058-I1
06/27/2022
Special inspection requirement — Fire-Resistant Penetrations and Joints
YEON LEE
04/06/2018
Violation issued (DOB, closed)
V*-DOB VIOLATION - DISMISSED
02/24/2017
Violation issued (DOB, closed)
V*-DOB VIOLATION - DISMISSED
03/02/2011
Violation issued (ECB, closed)
Construction
12/31/2009
Violation issued (DOB, closed)
V*-DOB VIOLATION - DISMISSED
05/28/2008
Violation issued (DOB, closed)
V*-DOB VIOLATION - DISMISSED
01/19/2007
Violation issued (DOB, closed)
V*-DOB VIOLATION - DISMISSED
12/22/2005
Violation issued (ECB, closed)
Construction
12/16/2005
Violation issued (ECB, closed)
Construction
06/28/1993
Violation issued (DOB, closed)
V*-DOB VIOLATION - DISMISSED
Permit / Filing Register
SourceWork TypeStatusApplicantIssued
DOB NOWPlumbingSigned-offC.R.U. MECHAN & HEAT INC07/01/2022
BISPLISSUEDSO PLUMBING & HEATING INC05/06/2019
BISOTISSUEDHIGH QUALITY CONSTRUCTION05/06/2019
BISPLISSUEDARANDA PLBG & HTG CORP11/28/2008
BISMHISSUEDAEG RESTORATION CORP11/19/2008
BISOTISSUEDDESIGN PLUS INTL INC05/19/2008
BISOTISSUEDKORMAN DESIGN & BUILD07/05/2007
BISPLISSUEDC.R.U. MECHAN & HEAT INC01/12/2006
BISOTISSUEDKORMAN DESIGN & BUILD12/28/2005
BISOTISSUEDKORMAN DESIGN & BUILD10/26/2005
Nothing on file for this building.
▾Field Inspections (DOB CAP) — 2
DateTypeResultReport
07/22/2022Pass-Final PL - Up to 3 Requested FloorsPassView ↗
07/07/2022Certified Gas-Gas-Piping-RoughingCertifiedView ↗
▾Special Inspection Requirements (DOB NOW) — 1
DateRequirementInspectorRole
06/27/2022Fire-Resistant Penetrations and JointsYEON LEEspecial
▾Documents — 55 on file (BIS + DOB NOW)
▸Plans & Drawings1
▸DOB NOWPlans/Sketch1
08/26/2026Q00765058-I1Request digital key ↗
▸Applications & Permits13
▸BISPLAN / WORK APPROVAL APPLICATION7
05/15/2019421742136Open ↗
03/31/2011410111409Open ↗
07/20/2010410191652Open ↗
Showing 3 of 7 on file for this type
▸BISWORK PERMIT APPLICATION6
05/15/2019421742136Open ↗
05/15/2019421742136Open ↗
11/29/2008410191652Open ↗
Showing 3 of 6 on file for this type
▸Seals & Professional Certifications12
▸BISTECHNICAL REPORT: RESPONSIBILITY/CERTIFICATION4
05/15/2019421742136Open ↗
06/10/2011410111409Open ↗
11/19/2008410191652Open ↗
Showing 3 of 4 on file for this type
▸BISPROFESSIONAL CERTIFIED CHECKLIST3
05/15/2019421742136Open ↗
11/19/2008410191652Open ↗
05/14/2008410111409Open ↗
▸BISPROFESSIONAL CERTIFICATION STATEMENT FORM2
11/19/2008410191652Open ↗
05/14/2008410111409Open ↗
▸BISPROFESSIONAL CERTIFICATION STATEMENT1
05/15/2019421742136Open ↗
▸DOB NOWDPL-1: Design Professional Seal & Signature1
08/13/2026Q00765058-I1Open ↗
▸DOB NOWSpecial Inspector Seal & Signature1
08/24/2026Q00765058-I1Open ↗
▸Trade Schedules & Equipment10
▸BISSCHEDULE C - HEATING & COMBUSTION EQUIPMENT7
05/20/2010410191652Open ↗
05/20/2010410191652Open ↗
04/30/2010410191652Open ↗
Showing 3 of 7 on file for this type
▸BISSCHEDULE B - PLUMBING2
11/19/2008410191652Open ↗
05/14/2008410111409Open ↗
▸BISSCHEDULE B - PLUMBING/SPRINKLER/STANDPIPE1
05/15/2019421742136Open ↗
▸Safety & Tenant Protection1
▸BISTenant Protection Plan and Notes1
05/15/2019421742136Open ↗
▸Environmental & Asbestos4
▸BISTHIS IS 'NOT AN ASBESTOS PROJECT'2
11/19/2008410191652Open ↗
05/14/2008410111409Open ↗
▸BISASBESTOS: CERTIFICATION (DEP ACP5)1
05/15/2019421742136Open ↗
▸DOB NOWDEP ACP-5: Asbestos Assessment Report1
08/13/2026Q00765058-I1Open ↗
▸Energy Compliance1
▸BISTECHNICAL REPORT: ENERGY CODE PROGRESS INSPS1
05/15/2019421742136Open ↗
▸Approvals, Objections & Sign-offs4
▸BISCERTIFICATE OF OCCUPANCY/LOC: REQUEST2
06/06/2011410111409Open ↗
05/24/2011410111409Open ↗
▸BISADMINISTRATIVE OBJECTIONS2
11/13/2008410191652Open ↗
05/14/2008410111409Open ↗
▸Cost, Insurance & Ownership5
▸BISCOST AFFIDAVIT5
05/15/2019421742136Open ↗
06/10/2011410111409Open ↗
04/14/2011410111409Open ↗
Showing 3 of 5 on file for this type
▸Filing & Intake Forms4
▸BISEFILING COVER SHEET3
05/15/2019421742136Open ↗
11/19/2008410191652Open ↗
05/14/2008410111409Open ↗
▸BISADDITIONAL INFORMATION1
06/24/2009410191652Open ↗