← Back
Office with commercial, 1-6 stories
43 MEADOW STREET
BROOKLYN · BIN 3380027
💬 Discuss this project
1930Year Built
2Stories
O5Building Class
M1-2Zoning
55,184 sfGross Floor Area
66Units
LL97 Covered1 Open Violation 0 unresolved · 1 paperwork only ▸FDNY Report ↗
Office with commercial, 1-6 stories · Owner of record: ACME REALTY INC · 39,740 sf lot · 1.39 FAR built · Flood zone X
Locations of Work
ArchitectureStructuralMechanicalPlumbingFire ProtectionLandscape
Permit Issued — active, not yet Signed-off
RoofUnder Construction1 filing · 20 docs
Floor 1Under Construction39p · 3 filings · 20 docs
CellarUnder Construction29p · 2 filings · 20 docs
▾Owner History (Filing Record)
Companies and organizations named on filings. Individual owners are not shown.
OwnerFilingsMost Recent
REFUGE2909/15/2026
▾Design Consultants (Architect / Engineer of Record)
▾Filing Representatives (Expediters)
RepresentativeFilingsMost Recent
MUNICIPAL BUILDING CONSULTANTS103/21/2026
JAM CONSULTANTS, INC.3203/21/2026
▾Contractors (License-Anchored)
FirmTradeRolesMost Recent
WILTON CONSTRUCTION MNGRSGeneral Contractor709/15/2026
STREAMLINE USA LLCGeneral Contractor407/08/2026
MALTA BUILDERSGeneral Contractor108/30/2026
WINICK PRODUCTIONS, LLCGeneral Contractor104/09/2026
BEDROCK PLBG. & HTG., INCPlumbing107/08/2026
ASCO SPRINKLER CO.,INCFire Protection107/08/2026
BROOK PLUMBING & HTG CORPPlumbing106/28/2026
BROOK PLUMBING & HTG CORPFire Protection106/28/2026
▾Special Inspection Agencies
AgencyLicense #FilingsMost Recent
SE INSPECTIONS7486607/30/2026
BENDIX ENGINEERING, P.C.42931109/26/2025
Building Lifecycle
All (104)Filed (30)Permit Issued (11)Signed Off (4)Inspection (15)Objection (14)Special Inspection (30)
09/14/2026
Permit issued — Structural
B01110512-S5-ST
08/28/2026
Permit issued — General Construction
B01362985-I1-GC
07/30/2026
Filed — Alteration
Install condensing unit, air handling unit and associated ductwork for bathroom buildout.
B01362985-S1
07/30/2026
Filed — Alteration
Install condensing unit, air handling unit and associated ductwork for bathroom buildout.
B01362985-S2
07/30/2026
Filed — Alteration
Install condensing unit, air handling unit and associated ductwork for bathroom buildout.
B01362985-S3
07/29/2026
Filed — Alteration
Install condensing unit, air handling unit and associated ductwork for bathroom buildout.
B01362985-I1
07/24/2026
Objection resolved — Addressed
07/23/2026
Objection raised — Other
07/15/2026
Filed — No Work
B01430029-I1
04/29/2026
Objection resolved — Addressed
04/28/2026
Objection raised — Other
04/27/2026
Filed — No Work
B01392979-I1
02/20/2026
Special inspection requirement — Final
Spencer Goroff
02/20/2026
Special inspection requirement — Maintenance information
Spencer Goroff
02/20/2026
Special inspection requirement — Fire-Resistant Penetrations and Joints
Spencer Goroff
02/20/2026
Special inspection requirement — Sprinkler Systems
Spencer Goroff
02/20/2026
Special inspection requirement — Post-installed Anchors
Spencer Goroff
02/20/2026
Special inspection requirement — Fire-Resistant Penetrations and Joints
Spencer Goroff
02/20/2026
Special inspection requirement — HVAC-R and service water heating equipment
Spencer Goroff
02/20/2026
Special inspection requirement — HVAC-R and service water piping design and insulation
Spencer Goroff
02/20/2026
Special inspection requirement — Mechanical Systems
Spencer Goroff
02/20/2026
Special inspection requirement — HVAC-R and service water heating system controls
Spencer Goroff
02/04/2026
Permit issued — General Construction
B01343545-I1-GC
01/16/2026
Objection resolved — Addressed
01/14/2026
Objection raised — Other
01/13/2026
Filed — Alteration
Temporary structures for event programming. Removed at the end of the programing. No changes to existing structures, use or egress.
B01343545-I1
01/12/2026
Filed — No Work
B01345018-I1
01/07/2026
Special inspection requirement — Final
ANDY ENGLER ROTH
09/30/2025
Filed — No Work
B01295625-I1
09/26/2025
Filed — Alteration
Remove existing gas piping and plumbing fixtures as indicated on the plans and risers.
B01061115-P6
09/26/2025
Special inspection requirement — Fire-Resistant Penetrations and Joints
Matthew Bendix
09/08/2025
Inspection — Certified Sprinkler-SP-Fixtures-Finish
Certified
View inspection ↗
09/07/2025
Signed off — Alteration
Interior alterations including a new bar, new partitions, doors, windows, flooring, light fixtures, plumbing fixtures and finishes. One existing stair will be replaced, and the existing trusses will be reinforced.
B01110512-I1
09/07/2025
Signed off — Alteration
Remove existing gas piping and plumbing fixtures as indicated on the plans and risers.
B01061115-I1
09/03/2025
Filed — No Work
B01280869-I1
09/03/2025
Inspection — Certified Sprinkler-SP-Piping Dry/Wet-Hydrostatic Test
Certified
View inspection ↗
09/03/2025
Inspection — Certified Sprinkler - SP - Roughing
Certified
View inspection ↗
08/29/2025
Inspection — Pass-Final CND-Occupancy Inspection
Pass
View inspection ↗
08/20/2025
Filed — Alteration
Interior alterations including a new bar, new partitions, doors, windows, flooring, light fixtures, plumbing fixtures and finishes. One existing stair will be replaced, and the existing trusses will be reinforced.
B01110512-P1
08/20/2025
Special inspection requirement — Final
Spencer Goroff
08/20/2025
Special inspection requirement — Concrete - Cast-In-Place
Spencer Goroff
08/20/2025
Special inspection requirement — Interior lighting power
Spencer Goroff
08/20/2025
Special inspection requirement — Lighting controls
Spencer Goroff
08/20/2025
Special inspection requirement — Interior lighting power
Spencer Goroff
08/20/2025
Special inspection requirement — Fire-Resistance Rated Construction
Spencer Goroff
08/20/2025
Special inspection requirement — Final
Spencer Goroff
08/20/2025
Special inspection requirement — Fire-Resistant Penetrations and Joints
Spencer Goroff
08/20/2025
Special inspection requirement — Fire-Resistant Penetrations and Joints
Matthew Bendix
08/20/2025
Special inspection requirement — Concrete - Cast-In-Place
Spencer Goroff
08/20/2025
Special inspection requirement — Fire-Resistant Penetrations and Joints
Spencer Goroff
08/20/2025
Special inspection requirement — Fire-Resistance Rated Construction
Spencer Goroff
08/20/2025
Special inspection requirement — Lighting controls
Spencer Goroff
05/30/2025
Inspection — Certified Water and Sanitary-WS-Sanitary Piping-Roughing
Certified
View inspection ↗
05/30/2025
Inspection — Certified Water and Sanitary-WS-Sanitary Piping-Underground
Certified
View inspection ↗
05/28/2025
Objection raised — Cost
05/28/2025
Objection resolved — Addressed
05/22/2025
Filed — Alteration
Interior alterations including a new bar, new partitions, doors, windows, flooring, light fixtures, plumbing fixtures and finishes. One existing stair will be replaced, and the existing trusses will be reinforced.
B01110512-S5
05/19/2025
Permit issued — Mechanical Systems
B01110512-S1-MS
05/19/2025
Special inspection requirement — Post-installed Anchors
05/19/2025
Special inspection requirement — Structural Steel - Welding
Latest 60 of 104 events.
Permit / Filing Register
SourceWork TypeStatusApplicantIssued
DOB NOWStructuralPermit IssuedWILTON CONSTRUCTION MNGRS09/14/2026
DOB NOWGeneral ConstructionPermit IssuedMALTA BUILDERS CORP08/28/2026
DOB NOWGeneral ConstructionPermit IssuedWINICK PRODUCTIONS, LLC02/04/2026
DOB NOWMechanical SystemsPermit IssuedWILTON CONSTRUCTION MNGRS05/19/2025
DOB NOWPlumbingPermit IssuedBROOK PLUMBING & HTG CORP05/16/2025
DOB NOWSprinklersPermit IssuedSHARP PLUMBING CORP05/16/2025
DOB NOWGeneral ConstructionSigned-offWILTON CONSTRUCTION MNGRS05/15/2025
DOB NOWSprinklersSigned-offASCO SPRINKLER CO.,INC07/11/2024
DOB NOWPlumbingPermit IssuedBEDROCK PLBG. & HTG., INC07/03/2024
DOB NOWGeneral ConstructionSigned-offSTREAMLINE USA LLC06/21/2024
DOB NOWMechanical SystemsSigned-offSTREAMLINE USA LLC06/18/2024
3 projects · most recent 07/30/2026
Heating and Air Conditioning Systems Air Conditioning Systems Others
FiledStatusContractorScopeMake / Model / Capacity
07/30/2026Permit IssuedMALTA BUILDERS CORPHeating and Air Conditioning Systems
Heat / Cool
Lg ARNU123SJS4 13,600 BTU · Vrf Indoor ×1
ARNU243M2A4 27,300 BTU · Vrf Indoor ×1
ARUM036GSS5 3 tons · Vrf Outdoor ×1
09/26/2025Signed-offSTREAMLINE USA LLCAir Conditioning Systems
Cooling
Trane TWA180E30RAB 6,000 CFM · Condensing Unit ×6
08/20/2025Permit IssuedWILTON CONSTRUCTION MNGRSOthers
Other
Carrier NA 18,000 CFM · Ductwork ×4
3 projects · most recent 07/30/2026
Sprinkler System
FiledStatusContractorScope
07/30/2026——Sprinkler System
09/26/2025Signed-offASCO SPRINKLER COMPANY, INCSprinkler System
08/20/2025Permit IssuedBROOK PLUMBING & HTG CORPSprinkler System
3 projects · most recent 07/30/2026
Water/Sanitary Gas
FiledStatusContractorScope
07/30/2026——Water/Sanitary
09/26/2025Permit IssuedBEDROCK PLBG. & HTG., INCGas, Water/Sanitary
08/20/2025Permit IssuedBROOK PLUMBING & HTG CORPGas, Water/Sanitary
1 project · most recent 08/20/2025
Steel
FiledStatusContractorScope
08/20/2025Permit IssuedWILTON CONSTRUCTION MNGRSSteel
▾Field Inspections (DOB CAP) — 15
DateTypeResultReport
09/08/2025Certified Sprinkler-SP-Fixtures-FinishCertifiedView ↗
09/03/2025Certified Sprinkler-SP-Piping Dry/Wet-Hydrostatic TestCertifiedView ↗
09/03/2025Certified Sprinkler - SP - RoughingCertifiedView ↗
08/29/2025Pass-Final CND-Occupancy InspectionPassView ↗
05/30/2025Certified Water and Sanitary-WS-Sanitary Piping-RoughingCertifiedView ↗
05/30/2025Certified Water and Sanitary-WS-Sanitary Piping-UndergroundCertifiedView ↗
05/12/2025Pass-Final CND-Occupancy InspectionPassView ↗
10/03/2024Pass-Final CND-Occupancy InspectionPassView ↗
08/23/2024Pass-Final CND-Occupancy InspectionPassView ↗
07/31/2024Pass-Final PL - Up to 3 Requested FloorsPassView ↗
07/25/2024Certified Remove/Cap - work done in accordance with codeCertifiedView ↗
07/23/2024Certified Remove/Cap - work done in accordance with codeCertifiedView ↗
07/18/2024Certified Sprinkler-SP-Fixtures-FinishCertifiedView ↗
07/18/2024Pass-Final PL - Up to 3 Requested FloorsPassView ↗
07/16/2024Certified Sprinkler-SP-Piping Dry/Wet-Hydrostatic TestCertifiedView ↗
▾Special Inspection Requirements (DOB NOW) — 66
DateRequirementInspectorRole
02/20/2026Post-installed AnchorsSpencer Goroffspecial
02/20/2026Sprinkler SystemsSpencer Goroffspecial
02/20/2026Fire-Resistant Penetrations and JointsSpencer Goroffspecial
02/20/2026HVAC-R and service water heating equipmentSpencer Goroffenergy_progress
02/20/2026HVAC-R and service water piping design and insulationSpencer Goroffenergy_progress
02/20/2026HVAC-R and service water heating system controlsSpencer Goroffenergy_progress
02/20/2026Maintenance informationSpencer Goroffenergy_progress
02/20/2026FinalSpencer Goroffprogress
02/20/2026Fire-Resistant Penetrations and JointsSpencer Goroffspecial
02/20/2026Mechanical SystemsSpencer Goroffspecial
01/07/2026FinalANDY ENGLER ROTHprogress
09/26/2025Fire-Resistant Penetrations and JointsMatthew Bendixspecial
08/20/2025Lighting controlsSpencer Goroffenergy_progress
08/20/2025Fire-Resistance Rated ConstructionSpencer Goroffprogress
08/20/2025Fire-Resistant Penetrations and JointsSpencer Goroffspecial
08/20/2025Concrete - Cast-In-PlaceSpencer Goroffspecial
08/20/2025FinalSpencer Goroffprogress
08/20/2025Interior lighting powerSpencer Goroffenergy_progress
08/20/2025FinalSpencer Goroffprogress
08/20/2025Concrete - Cast-In-PlaceSpencer Goroffspecial
08/20/2025Fire-Resistant Penetrations and JointsSpencer Goroffspecial
08/20/2025Fire-Resistance Rated ConstructionSpencer Goroffprogress
08/20/2025Fire-Resistant Penetrations and JointsMatthew Bendixspecial
08/20/2025Interior lighting powerSpencer Goroffenergy_progress
08/20/2025Lighting controlsSpencer Goroffenergy_progress
Latest 25 of 66.
▾Documents — 138 on file (BIS + DOB NOW)
▸Plans & Drawings30
▸DOB NOWPlans/Sketch22
08/24/2026B01061115-I1Request digital key ↗
08/24/2026B01061115-S1Request digital key ↗
08/24/2026B01061115-S3Request digital key ↗
Showing 3 of 22 on file for this type
▸DOB NOWPlans/Sketch - Temporary Place of Assembly8
08/24/2026B01081676-I1Request digital key ↗
08/23/2026B01134765-I1Request digital key ↗
08/20/2026B01280869-I1Request digital key ↗
Showing 3 of 8 on file for this type
▸Seals & Professional Certifications87
▸DOB NOWProgress Inspector Seal & Signature35
09/01/2026B01110512-I1Open ↗
09/01/2026B01110512-I1Open ↗
09/01/2026B01110512-I1Open ↗
Showing 3 of 35 on file for this type
▸DOB NOWDPL-1: Design Professional Seal & Signature31
08/24/2026B01061115-P2Open ↗
08/24/2026B01061115-S2Open ↗
08/24/2026B01061115-P5Open ↗
Showing 3 of 31 on file for this type
▸DOB NOWSpecial Inspector Seal & Signature21
09/01/2026B01110512-I1Open ↗
09/01/2026B01110512-I1Open ↗
09/01/2026B01110512-P2Open ↗
Showing 3 of 21 on file for this type
▸Environmental & Asbestos21
▸DOB NOWDEP ACP-5: Asbestos Assessment Report21
08/24/2026B01061115-S2Open ↗
08/24/2026B01061115-P6Open ↗
08/24/2026B01061115-P5Open ↗
Showing 3 of 21 on file for this type