← Back
One story - permanent living quarter
43 VAN DUZER STREET
STATEN ISLAND · Tompkinsville-Stapleton-Clifton-Fox Hills · BIN 5013246
💬 Discuss this project
1925Year Built
1Stories
A2Building Class
R3-2Zoning
990 sfGross Floor Area
1Units
0 Open ViolationsFDNY Report ↗
One story - permanent living quarter · Owner of record: NEW YORK CITY INVESTMENT GROUP, LLC · 2,500 sf lot · 0.4 FAR built · Flood zone X
Locations of Work
ArchitectureStructuralElectricalMechanicalPlumbingFire ProtectionLandscapeCivilGeneralOther
Filed — no permit issued56p · 3 filings · 18 docs
▾Owner History (Filing Record)
Companies and organizations named on filings. Individual owners are not shown.
OwnerFilingsMost Recent
NEW YORK CITY INVESTMENT303/22/2026
TO THE OWNER OF PREMISES103/22/2026
▾Design Consultants (Architect / Engineer of Record)
FirmFilingsMost Recent
RYAN DESIGN ARCHITECTURE407/06/2023
Building Lifecycle
All (58)Filed (4)Violation (14)Objection (10)Special Inspection (30)
07/18/2023
Objection raised — Zoning
07/18/2023
Objection raised — Other
07/18/2023
Objection raised — Other
07/18/2023
Objection raised — Structural
07/18/2023
Objection raised — Other
07/18/2023
Objection raised — Other
07/18/2023
Objection raised — Other
07/06/2023
Filed — ALT-CO - New Building with Existing Elements to Remain
S00484989-P1
06/16/2023
Special inspection requirement — HVAC-R and service water piping design and insulation
06/16/2023
Special inspection requirement — Permanent certificate
06/16/2023
Special inspection requirement — Exterior Insulation and Finish Systems (EIFS)
06/16/2023
Special inspection requirement — Fenestration air leakage
06/16/2023
Special inspection requirement — Fenestration areas
06/16/2023
Special inspection requirement — Concrete - Cast-In-Place
06/16/2023
Special inspection requirement — Maintenance information
06/16/2023
Special inspection requirement — Lighting in dwelling units
06/16/2023
Special inspection requirement — Lighting controls
06/16/2023
Special inspection requirement — Fenestration and door U-factor and product ratings
06/16/2023
Special inspection requirement — Air barrier - visual inspection
06/16/2023
Special inspection requirement — Interior lighting power
06/16/2023
Special inspection requirement — Metering
06/16/2023
Special inspection requirement — Insulation placement and R values
06/16/2023
Special inspection requirement — Fire-Resistance Rated Construction
06/16/2023
Special inspection requirement — Energy Code Compliance Inspections
06/16/2023
Special inspection requirement — Subsurface Investigations (Borings/Test Pits)
06/16/2023
Special inspection requirement — Subgrade Inspections
06/16/2023
Special inspection requirement — Private On-Site Storm Water Disposal Systems-, and Detention Facilities, Installation
06/16/2023
Special inspection requirement — Fire-Resistant Penetrations and Joints
04/14/2023
Special inspection requirement — Subsurface Investigations (Borings/Test Pits)
12/29/2021
Objection raised — Admin
12/29/2021
Objection raised — Admin
12/29/2021
Objection raised — Scope
12/20/2021
Filed — Alteration
PLUMBING
S00529681-I1
12/20/2021
Special inspection requirement — Metering
12/20/2021
Special inspection requirement — Energy Code Compliance Inspections
12/20/2021
Special inspection requirement — HVAC-R and service water heating equipment
12/20/2021
Special inspection requirement — HVAC-R and service water heating system controls
12/20/2021
Special inspection requirement — Maintenance information
12/20/2021
Special inspection requirement — HVAC-R and service water piping design and insulation
12/17/2021
Filed — Alteration
S00502320-I1
11/01/2021
Filed — ALT-CO - New Building with Existing Elements to Remain
S00484989-I1
08/25/2021
Special inspection requirement — Fire-Resistance Rated Construction
08/25/2021
Special inspection requirement — Energy Code Compliance Inspections
08/25/2021
Special inspection requirement — Metering
06/02/2017
Violation issued (ECB, closed)
Construction
03/27/2017
Violation issued (ECB, closed)
Construction
03/08/2017
Violation issued (DOB, closed)
V*-DOB VIOLATION - DISMISSED
12/13/2016
Violation issued (ECB, closed)
Unknown
01/15/2014
Violation issued (DOB, closed)
V*-DOB VIOLATION - DISMISSED
01/15/2014
Violation issued (DOB, closed)
V*-DOB VIOLATION - DISMISSED
07/10/2013
Violation issued (ECB, closed)
Unknown
05/30/2013
Violation issued (ECB, closed)
Unknown
04/08/2013
Violation issued (ECB, closed)
Unknown
04/08/2013
Violation issued (ECB, closed)
Unknown
02/02/2013
Violation issued (ECB, closed)
Unknown
12/03/2012
Violation issued (ECB, closed)
Construction
12/03/2012
Violation issued (ECB, closed)
Construction
10/15/2009
Violation issued (ECB, closed)
Unknown
Nothing on file for this building.
1 project · most recent 12/20/2021
Gas Storm Water/Sanitary
FiledStatusContractorScope
12/20/2021——Gas, Storm, Water/Sanitary
▾Special Inspection Requirements (DOB NOW) — 46
DateRequirementInspectorRole
06/16/2023HVAC-R and service water piping design and insulation—energy_progress
06/16/2023Permanent certificate—energy_progress
06/16/2023Exterior Insulation and Finish Systems (EIFS)—special
06/16/2023Fenestration air leakage—energy_progress
06/16/2023Fenestration areas—energy_progress
06/16/2023Concrete - Cast-In-Place—special
06/16/2023Maintenance information—energy_progress
06/16/2023Lighting in dwelling units—energy_progress
06/16/2023Lighting controls—energy_progress
06/16/2023Fenestration and door U-factor and product ratings—energy_progress
06/16/2023Air barrier - visual inspection—energy_progress
06/16/2023Interior lighting power—energy_progress
06/16/2023Metering—energy_progress
06/16/2023Insulation placement and R values—energy_progress
06/16/2023Fire-Resistance Rated Construction—progress
06/16/2023Energy Code Compliance Inspections—progress
06/16/2023Subsurface Investigations (Borings/Test Pits)—special
06/16/2023Subgrade Inspections—special
06/16/2023Private On-Site Storm Water Disposal Systems-, and Detention Facilities, Installation—special
06/16/2023Fire-Resistant Penetrations and Joints—special
04/14/2023Subsurface Investigations (Borings/Test Pits)—special
12/20/2021Metering—energy_progress
12/20/2021Energy Code Compliance Inspections—progress
12/20/2021HVAC-R and service water heating equipment—energy_progress
12/20/2021HVAC-R and service water heating system controls—energy_progress
Latest 25 of 46.
▾Documents — 29 on file (BIS + DOB NOW)
▸Plans & Drawings4
▸DOB NOWPlans/Sketch4
08/25/2026S00484989-P1Request digital key ↗
08/25/2026S00484989-I1Request digital key ↗
08/24/2026S00502320-I1Request digital key ↗
Showing 3 of 4 on file for this type
▸Applications & Permits1
▸BISBPP-5 - Authorization to the Department of Transportation1
06/30/2020520454133Open ↗
▸Zoning, Tax Lot & Property Records5
▸DOB NOWZoning Exhibit form (1-5)2
08/13/2026S00484989-P1Open ↗
08/13/2026S00484989-I1Open ↗
▸DOB NOWZD1: DOB Zoning Diagram2
08/13/2026S00484989-I1Open ↗
08/13/2026S00484989-P1Open ↗
▸DOB NOWHouse Number Verification: TOPO Stamp1
08/13/2026S00484989-I1Open ↗
▸Seals & Professional Certifications4
▸DOB NOWDPL-1: Design Professional Seal & Signature4
08/25/2026S00484989-I1Open ↗
08/25/2026S00484989-P1Open ↗
08/24/2026S00502320-I1Open ↗
Showing 3 of 4 on file for this type
▸Trade Schedules & Equipment1
▸BISBOILERS - SUPPORTING DOCUMENTATION1
07/30/2020520454133Open ↗
▸Safety & Tenant Protection1
▸BISSTREET TREE CHECKLIST1
07/30/2020520454133Open ↗
▸Inspections & Test Reports3
▸DOB NOWSOIL REPORT2
08/13/2026S00484989-P1Open ↗
08/13/2026S00484989-I1Open ↗
▸BISBPP-9 - Request for Builders Pavement Field Inspection1
06/30/2020520454133Open ↗
▸Approvals, Objections & Sign-offs2
▸BISBPP-8 - Request Items for Builders Pavement Plan Signoff1
06/30/2020520454133Open ↗
▸BISLETTERS - SUPPORTING DOCUMENTATION1
06/30/2020520454133Open ↗
▸Filing & Intake Forms1
▸BISEFILING COVER SHEET1
05/29/2020520454133Open ↗
▸Other Documents7
▸BISBPP - SUPPORTING DOCUMENTATION3
06/30/2020520454133Open ↗
06/30/2020520454133Open ↗
06/30/2020520454133Open ↗
▸DOB NOWLocal Law 92/94 of 2019 Sustainable Roof Zone2
08/13/2026S00484989-I1Open ↗
08/13/2026S00484989-P1Open ↗
▸BISBPP - DOT Builders Pavement Unit Waiver Request Form1
07/30/2020520454133Open ↗
▸DOB NOWSite Survey: Initial1
08/13/2026S00484989-P1Open ↗