← Back
Four families
430 LOGAN STREET
BROOKLYN · BIN 3094558
💬 Discuss this project
1925Year Built
2Stories
C3Building Class
R5BZoning
3,200 sfGross Floor Area
4Units
Rent Stabilized0 Open ViolationsFDNY Report ↗
Four families · 2,800 sf lot · 1.14 FAR built · Flood zone X
Locations of Work
No floor-level scope or drawing coverage on file for this building.
Nothing on file for this building.
Building Lifecycle
All (21)Filed (2)Permit Issued (1)Violation (8)Inspection (2)Special Inspection (8)
03/31/2022
Violation issued (HPD, closed)
C
03/31/2022
Violation issued (HPD, closed)
B
03/31/2022
Violation issued (HPD, closed)
B
03/31/2022
Violation issued (HPD, closed)
B
11/01/2021
Inspection — Certified Water and Sanitary-WS-Fixtures-Finish
Certified
View inspection ↗
10/28/2021
Inspection — Pass-Final PL - Up to 3 Requested Floors
Pass
View inspection ↗
10/26/2021
Special inspection requirement — Maintenance information
JOSEPH BOTTA
10/26/2021
Special inspection requirement — Energy Code Compliance Inspections
JOSEPH BOTTA
10/26/2021
Special inspection requirement — HVAC-R and service water heating equipment
JOSEPH BOTTA
10/26/2021
Special inspection requirement — HVAC-R and service water heating system controls
JOSEPH BOTTA
10/22/2021
Filed — Alteration
Replacement of gas fired heating boiler and four gas fired domestic hot water heaters connected to existing gas services, meters and piping. No change in use, occupancy or egress.
B00527305-P1
10/22/2021
Special inspection requirement — Energy Code Compliance Inspections
JOSEPH BOTTA
10/22/2021
Special inspection requirement — Maintenance information
JOSEPH BOTTA
10/22/2021
Special inspection requirement — HVAC-R and service water heating equipment
JOSEPH BOTTA
10/22/2021
Special inspection requirement — HVAC-R and service water heating system controls
JOSEPH BOTTA
10/18/2021
Violation issued (HPD, closed)
C
10/18/2021
Violation issued (HPD, closed)
A
06/08/2021
Permit issued — Plumbing
B00527305-I1-PL
05/24/2021
Filed — Alteration
Replacement of gas fired heating boiler and four gas fired domestic hot water heaters connected to existing gas services, meters and piping. No change in use, occupancy or egress.
B00527305-I1
04/09/2021
Violation issued (HPD, closed)
A
09/18/2016
Violation issued (HPD, closed)
B
▾Design Consultants (Architect / Engineer of Record)
FirmFilingsMost Recent
JOSEPH BOTTA, PE, PC210/22/2021
▾Contractors (License-Anchored)
FirmTradeRolesMost Recent
PAUL TRAKTMAN LIC PLBR INPlumbing207/08/2026
Permit / Filing Register
SourceWork TypeStatusApplicantIssued
DOB NOWPlumbingSigned-offPAUL TRAKTMAN LIC PLBR IN06/08/2021
▾Field Inspections (DOB CAP) — 2
DateTypeResultReport
11/01/2021Certified Water and Sanitary-WS-Fixtures-FinishCertifiedView ↗
10/28/2021Pass-Final PL - Up to 3 Requested FloorsPassView ↗
▾Special Inspection Requirements (DOB NOW) — 8
DateRequirementInspectorRole
10/26/2021Maintenance informationJOSEPH BOTTAenergy_progress
10/26/2021Energy Code Compliance InspectionsJOSEPH BOTTAprogress
10/26/2021HVAC-R and service water heating equipmentJOSEPH BOTTAenergy_progress
10/26/2021HVAC-R and service water heating system controlsJOSEPH BOTTAenergy_progress
10/22/2021Energy Code Compliance InspectionsJOSEPH BOTTAprogress
10/22/2021Maintenance informationJOSEPH BOTTAenergy_progress
10/22/2021HVAC-R and service water heating equipmentJOSEPH BOTTAenergy_progress
10/22/2021HVAC-R and service water heating system controlsJOSEPH BOTTAenergy_progress
▾Documents — 15 on file (BIS + DOB NOW)
▸Plans & Drawings2
▸DOB NOWPlans/Sketch2
09/01/2026B00527305-I1Request digital key ↗
09/01/2026B00527305-P1Request digital key ↗
▸Seals & Professional Certifications10
▸DOB NOWProgress Inspector Seal & Signature8
08/27/2026B00527305-I1Open ↗
08/27/2026B00527305-I1Open ↗
08/27/2026B00527305-I1Open ↗
Showing 3 of 8 on file for this type
▸DOB NOWDPL-1: Design Professional Seal & Signature2
09/01/2026B00527305-P1Open ↗
09/01/2026B00527305-I1Open ↗
▸Environmental & Asbestos2
▸DOB NOWDEP ACP-5: Asbestos Assessment Report2
09/01/2026B00527305-P1Open ↗
09/01/2026B00527305-I1Open ↗
▸Energy Compliance1
▸DOB NOWEN2: As Built Energy Analysis.1
09/01/2026B00527305-I1Open ↗