← Back
Primarily 2 family with 1 store or office
4305 15 AVENUE
BROOKLYN · BIN 3128225
💬 Discuss this project
1920Year Built
3Stories
S2Building Class
R6Zoning
3,920 sfGross Floor Area
3Units
1 Open Violation 0 unresolved · 1 paperwork only ▸FDNY Report ↗
Primarily 2 family with 1 store or office · Owner of record: 4301-15TH AVENUE REALTY ASSOCIATES · 2,000 sf lot · 1.96 FAR built · Flood zone X
Locations of Work
ArchitectureMechanical
Roof2p · 2 filings · 9 docs
Floor 31p · 1 filing · 4 docs
Floor 21p · 1 filing · 4 docs
Floor 11p · 1 filing · 4 docs
Cellar1p · 1 filing · 4 docs
▾Owner History (Filing Record)
Companies and organizations named on filings. Individual owners are not shown.
OwnerFilingsMost Recent
4301 15TH AVENUE REALTY103/22/2026
▾Design Consultants (Architect / Engineer of Record)
FirmFilingsMost Recent
FRAMEWORK ENGINEERING PC106/11/2026
RMM DESIGN STUDIO103/27/2026
SOHAIL HUMAYUN P E INC101/31/2025
▾Filing Representatives (Expediters)
RepresentativeFilingsMost Recent
SAGACITY BUILDING SERVICES103/21/2026
▾Special Inspection Agencies
AgencyLicense #FilingsMost Recent
AA BUILDING & INSPECTION1519103/27/2026
SOHAIL HUMAYUN P E INC8457101/31/2025
Building Lifecycle
All (29)Filed (3)Violation (1)Objection (14)Special Inspection (11)
08/11/2026
Objection resolved — Resolved
08/11/2026
Objection resolved — Resolved
08/11/2026
Objection resolved — Resolved
08/11/2026
Objection resolved — Resolved
08/11/2026
Objection resolved — Resolved
07/07/2026
Objection raised — Scope
07/07/2026
Objection raised — Scope
07/07/2026
Objection raised — Zoning
07/07/2026
Objection raised — Zoning
07/07/2026
Objection raised — Other
06/11/2026
Filed — Alteration CO
B01339891-I1
06/04/2026
Special inspection requirement — Interior lighting power
06/04/2026
Special inspection requirement — Fire-Resistance Rated Construction
06/04/2026
Special inspection requirement — Lighting controls
06/04/2026
Special inspection requirement — Insulation placement and R values
06/04/2026
Special inspection requirement — Fire-Resistant Penetrations and Joints
06/04/2026
Special inspection requirement — Masonry
06/04/2026
Special inspection requirement — Structural Stability – Alterations of existing buildings
06/04/2026
Special inspection requirement — Energy Code Compliance Inspections
04/20/2026
Objection raised — Other
04/20/2026
Objection resolved — Resolved
04/20/2026
Objection raised — Other
04/20/2026
Objection resolved — Resolved
03/27/2026
Filed — Alteration
INSTALLATION OF SOLAR PANELS ON EXISTING ROOF. NO CHANGE IN USE, OCCUPANCY, OR EGRESS. NO CHANGE IN BULK
B01378440-I1
03/25/2026
Special inspection requirement — Energy Code Compliance Inspections
JEFFREY BELL
03/25/2026
Special inspection requirement — Final
RICHARD MUESCH JR.
03/25/2026
Special inspection requirement — Fire-Resistant Penetrations and Joints
Younes Abouyaala
01/31/2025
Filed — Alteration
B01170855-I1
06/18/2009
Violation issued (ECB, open)
Construction
Permit / Filing Register
SourceWork TypeStatusApplicantIssued
BISFPISSUEDLUND FIRE PRODUCTS CO INC06/21/2005
BISFPISSUEDIDEAL FIRE CONTROL02/28/1995
1 project · most recent 03/23/2026
FiledStatusContractorScope
03/23/2026Permit IssuedAMBER ELECTL CONTNG INC—
1 project · most recent 03/27/2026
FiledStatusContractorScope
03/27/2026——25 panels, 20.3 kw, 2,000 roof_area_sqft
▾Special Inspection Requirements (DOB NOW) — 11
DateRequirementInspectorRole
06/04/2026Interior lighting power—energy_progress
06/04/2026Fire-Resistance Rated Construction—progress
06/04/2026Lighting controls—energy_progress
06/04/2026Insulation placement and R values—energy_progress
06/04/2026Fire-Resistant Penetrations and Joints—special
06/04/2026Masonry—special
06/04/2026Structural Stability – Alterations of existing buildings—special
06/04/2026Energy Code Compliance Inspections—progress
03/25/2026Energy Code Compliance InspectionsJEFFREY BELLprogress
03/25/2026FinalRICHARD MUESCH JR.progress
03/25/2026Fire-Resistant Penetrations and JointsYounes Abouyaalaspecial
▾Documents — 13 on file (BIS + DOB NOW)
▸Plans & Drawings3
▸DOB NOWPlans/Sketch3
08/23/2026B01170855-I1Request digital key ↗
08/17/2026B01378440-I1Request digital key ↗
08/14/2026B01339891-I1Request digital key ↗
▸Zoning, Tax Lot & Property Records1
▸DOB NOWZD1: DOB Zoning Diagram1
08/14/2026B01339891-I1Open ↗
▸Seals & Professional Certifications6
▸DOB NOWDPL-1: Design Professional Seal & Signature3
08/23/2026B01170855-I1Open ↗
08/17/2026B01378440-I1Open ↗
08/16/2026B01339891-I1Open ↗
▸DOB NOWProgress Inspector Seal & Signature2
08/28/2026B01378440-I1Open ↗
08/28/2026B01378440-I1Open ↗
▸DOB NOWSpecial Inspector Seal & Signature1
08/28/2026B01378440-I1Open ↗
▸Environmental & Asbestos2
▸DOB NOWDEP ACP-5: Asbestos Assessment Report2
08/23/2026B01170855-I1Open ↗
08/17/2026B01378440-I1Open ↗
▸Other Documents1
▸DOB NOWSite Survey: Initial1
08/14/2026B01339891-I1Open ↗