← Back
Miscellaneous two family
432 EAST 136 STREET
BRONX · Mott Haven-Port Morris · BIN 2000200
💬 Discuss this project
1891Year Built
3Stories
B9Building Class
R6Zoning
2,115 sfGross Floor Area
2Units
Rent Stabilized0 Open ViolationsFDNY Report ↗
Miscellaneous two family · 1,500 sf lot · 1.41 FAR built · Flood zone X
Locations of Work
ArchitectureElectricalGeneral
Permit Issued — active, not yet Signed-off
RoofUnder Construction9p · 1 filing · 18 docs
▾Sales History (ACRIS)
DatePriceUnitSeller → Buyer$/sf
02/28/2024$935K—— → —$442/sf building
09/20/2017$495K—— → —$234/sf building
▾Design Consultants (Architect / Engineer of Record)
FirmFilingsMost Recent
TOM PETERSEN ARCHITECT, LLC203/02/2026
▾Contractors (License-Anchored)
FirmTradeRolesMost Recent
VILLAGE ELECTL CONTRS INCElectrical103/22/2026
SOLAR CONTRACTING LLCGeneral Contractor104/09/2026
▾Special Inspection Agencies
AgencyLicense #FilingsMost Recent
THOMAS PETERSEN ARCHITECT7854203/02/2026
Building Lifecycle
All (21)Filed (2)Permit Issued (1)Violation (4)Objection (4)Special Inspection (10)
04/03/2026
Permit issued — Solar
X01343310-I1-SL
03/20/2026
Special inspection requirement — Structural Stability – Alterations of existing buildings
TOM PETERSEN
03/20/2026
Special inspection requirement — Fire-Resistant Penetrations and Joints
TOM PETERSEN
03/20/2026
Special inspection requirement — Energy Code Compliance Inspections
TOM PETERSEN
03/20/2026
Special inspection requirement — Final
TOM PETERSEN
03/20/2026
Special inspection requirement — Air barrier - visual inspection
TOM PETERSEN
03/02/2026
Filed — Alteration
SCOPE OF WORK IS SOLELY FOR THE INSTALLATION OF THE SOLAR ELECTRONIC GENERATING SYSTEM.ALL OTHER WORK IS NOT TO BE RELIED UPON AS BEING APPROVED AND/OR PERMITTED BY THENYC DEPARTMENT OF BUILDINGS.
X01343310-P2
03/02/2026
Special inspection requirement — Fire-Resistant Penetrations and Joints
TOM PETERSEN
03/02/2026
Special inspection requirement — Structural Stability – Alterations of existing buildings
TOM PETERSEN
03/02/2026
Special inspection requirement — Energy Code Compliance Inspections
TOM PETERSEN
03/02/2026
Special inspection requirement — Final
TOM PETERSEN
03/02/2026
Special inspection requirement — Air barrier - visual inspection
TOM PETERSEN
02/11/2026
Objection resolved — Addressed
02/10/2026
Objection resolved — Addressed
01/26/2026
Objection raised — Admin
01/26/2026
Objection raised — Admin
01/09/2026
Filed — Alteration
SCOPE OF WORK IS SOLELY FOR THE INSTALLATION OF THE SOLAR ELECTRONIC GENERATING SYSTEM.ALL OTHER WORK IS NOT TO BE RELIED UPON AS BEING APPROVED AND/OR PERMITTED BY THENYC DEPARTMENT OF BUILDINGS.
X01343310-I1
10/19/2022
Violation issued (HPD, closed)
B
10/19/2022
Violation issued (HPD, closed)
B
10/19/2022
Violation issued (HPD, closed)
B
10/19/2022
Violation issued (HPD, closed)
B
Permit / Filing Register
SourceWork TypeStatusApplicantIssued
DOB NOWSolarPermit IssuedSOLAR CONTRACTING LLC04/03/2026
3 projects · most recent 01/08/2026
FiledStatusContractorScope
01/08/2026Permit IssuedSOLAR ELEC CONTRACTNG LLC3 meters
01/08/2026Permit IssuedSOLAR ELEC CONTRACTNG LLC—
10/14/2025Permit IssuedVILLAGE ELECTL CONTRS INC—
1 project · most recent 03/02/2026
FiledStatusContractorScope
03/02/2026Permit IssuedSOLAR CONTRACTING LLC50 panels, 21.5 kw, 588.24 roof_area_sqft
▾Special Inspection Requirements (DOB NOW) — 10
DateRequirementInspectorRole
03/20/2026Structural Stability – Alterations of existing buildingsTOM PETERSENspecial
03/20/2026Fire-Resistant Penetrations and JointsTOM PETERSENspecial
03/20/2026Energy Code Compliance InspectionsTOM PETERSENprogress
03/20/2026FinalTOM PETERSENprogress
03/20/2026Air barrier - visual inspectionTOM PETERSENenergy_progress
03/02/2026Fire-Resistant Penetrations and JointsTOM PETERSENspecial
03/02/2026Structural Stability – Alterations of existing buildingsTOM PETERSENspecial
03/02/2026Energy Code Compliance InspectionsTOM PETERSENprogress
03/02/2026FinalTOM PETERSENprogress
03/02/2026Air barrier - visual inspectionTOM PETERSENenergy_progress
▾Documents — 18 on file (BIS + DOB NOW)
▸Plans & Drawings2
▸DOB NOWPlans/Sketch2
08/17/2026X01343310-P2Request digital key ↗
08/17/2026X01343310-I1Request digital key ↗
▸Applications & Permits2
▸DOB NOWLPC Approval/Permit2
08/17/2026X01343310-I1Open ↗
08/13/2026X01343310-P2Open ↗
▸Seals & Professional Certifications12
▸DOB NOWProgress Inspector Seal & Signature6
09/01/2026X01343310-P2Open ↗
09/01/2026X01343310-P2Open ↗
09/01/2026X01343310-P2Open ↗
Showing 3 of 6 on file for this type
▸DOB NOWSpecial Inspector Seal & Signature4
09/01/2026X01343310-P2Open ↗
09/01/2026X01343310-P2Open ↗
08/24/2026X01343310-I1Open ↗
Showing 3 of 4 on file for this type
▸DOB NOWDPL-1: Design Professional Seal & Signature2
08/17/2026X01343310-I1Open ↗
08/13/2026X01343310-P2Open ↗
▸Environmental & Asbestos2
▸DOB NOWDEP ACP-5: Asbestos Assessment Report2
08/17/2026X01343310-I1Open ↗
08/13/2026X01343310-P2Open ↗