| Owner | Filings | Most Recent |
|---|---|---|
| 436 West 20 Street | 12 | 03/21/2026 |
| 436 W 20 St | 3 | 03/21/2026 |
| Firm | Filings | Most Recent |
|---|---|---|
| Sharon Associates | 8 | 01/27/2026 |
| Melamed Architect | 2 | 09/11/2024 |
| BHK Engineering | 1 | 10/27/2023 |
| Mje Professional Services | 3 | 06/09/2023 |
| Representative | Filings | Most Recent |
|---|---|---|
| BMB Building Consulting | 22 | 03/21/2026 |
| Firm | Trade | Roles | Most Recent |
|---|---|---|---|
| Empire City Construction | Scaffold | 13 | 07/08/2026 |
| JJS Management | General Contractor | 9 | 07/08/2026 |
| Kwong Ming Electric | Electrical | 3 | 03/21/2026 |
| Empire Plumbing | Plumbing | 2 | 07/08/2026 |
| 5 J'S Electl Conts | Electrical | 1 | 03/22/2026 |
| Verrazano Plumbing Cont | Plumbing | 1 | 07/08/2026 |
| AE Electric | Electrical | 1 | 03/21/2026 |
| BT's Plumbing and Heating | Plumbing | 1 | 07/08/2026 |
| Expert Fire Sprinkler | Fire Protection | 1 | 07/08/2026 |
| Agency | License # | Filings | Most Recent |
|---|---|---|---|
| Steel Core Engineering PL | 1098 | 10 | 01/27/2026 |
| BHK Engineering | 9589 | 1 | 10/27/2023 |
| Source | Work Type | Status | Applicant | Issued |
|---|---|---|---|---|
| DOB NOW | Structural | Signed-off | JJS Management | 05/18/2026 |
| DOB NOW | Sprinklers | Permit Issued | Expert Fire Sprinkler | 12/03/2025 |
| DOB NOW | Plumbing | Permit Issued | BT's Plumbing and Heating | 09/11/2025 |
| DOB NOW | Sidewalk Shed | Signed-off | Empire City Construction | 09/23/2024 |
| DOB NOW | Construction Fence | Signed-off | Empire City Construction | 09/23/2024 |
| DOB NOW | Supported Scaffold | Signed-off | Empire City Construction | 09/23/2024 |
| DOB NOW | General Construction | Permit Issued | JJS Management | 02/01/2024 |
| DOB NOW | Plumbing | Permit Issued | Verrazano Plumbing Cont | 10/26/2023 |
| DOB NOW | Mechanical Systems | Signed-off | JJS Management | 10/25/2023 |
| DOB NOW | Sidewalk Shed | Signed-off | Empire City Construction | 09/13/2023 |
| DOB NOW | Construction Fence | Signed-off | Empire City Construction | 09/13/2023 |
| DOB NOW | Supported Scaffold | Signed-off | Empire City Construction | 09/12/2023 |
| DOB NOW | Sidewalk Shed | Signed-off | Empire City Construction | 06/09/2023 |
| DOB NOW | Construction Fence | Signed-off | Empire City Construction | 06/09/2023 |
| DOB NOW | Supported Scaffold | Signed-off | Empire City Construction | 06/09/2023 |
| DOB NOW | Plumbing | Permit Issued | Empire Plumbing | 04/20/2023 |
| DOB NOW | Sprinklers | Permit Issued | Empire Plumbing | 03/17/2023 |
| DOB NOW | General Construction | Permit Issued | JJS Management | 02/08/2023 |
| DOB NOW | Mechanical Systems | Signed-off | JJS Management | 11/10/2022 |
| BIS | PL | ISSUED | Demar Plumbing | 01/24/2013 |
| BIS | MH | ISSUED | Damo Construction Co | 01/21/2011 |
| BIS | OT | ISSUED | Damo Construction Co | 01/18/2011 |
| BIS | EQ | ISSUED | LKR Construction | 03/17/2010 |
| BIS | PL | ISSUED | Metro | 03/15/2010 |
| BIS | MH | ISSUED | Damo Construction Co | 12/28/2009 |
| BIS | MH | ISSUED | Katz Metal Fabricators | 10/09/2009 |
| BIS | PL | ISSUED | Metro | 03/17/2009 |
| BIS | OT | ISSUED | Damo Construction Co | 02/20/2009 |
| BIS | PL | ISSUED | New York Heating | 10/19/2007 |
| BIS | BL | ISSUED | New York Heating | 10/19/2007 |
| BIS | PL | ISSUED | Wasoff Plumbing & Utility Co | 02/13/1998 |
| BIS | BL | ISSUED | Wasoff Plumbing & Utility Co | 02/13/1998 |
| Filed | Status | Contractor | Scope | Make / Model / Capacity |
|---|---|---|---|---|
| 01/27/2026 | Signed-off | JJS Management | Air Conditioning Systems, Heating Systems, Ventilation Systems | Cooling Mitsubishi Electric MXZ-4C36NAHZ2 36,000 BTU · Condensing Unit ×4 MXZ-3C24NAHZ2 23,600 BTU · Condensing Unit ×2 MXZ-3C30NAHZ2 27,400 BTU · Condensing Unit ×2 PUZ-HA30NHA5 27,000 BTU · Condensing Unit ×2 Heating Mitsubishi Electric MXZ-4C36NAHZ2 45,000 BTU · Condensing Unit ×4 MXZ-3C24NAHZ2 24,600 BTU · Condensing Unit ×2 MXZ-3C30NAHZ2 27,600 BTU · Condensing Unit ×2 PUZ-HA30NHA5 32,000 BTU · Condensing Unit ×2 Berko FRC4020 6,825 BTU · Electric Heater ×6 Ventilation Greenheck SP-B70 50 CFM · Exhaust Fan ×6 |
| Filed | Status | Contractor | Scope |
|---|---|---|---|
| 01/27/2026 | Permit Issued | BT's Plumbing and Heating | Gas, Storm, Water/Sanitary |
| Filed | Status | Contractor | Scope |
|---|---|---|---|
| 07/14/2026 | Pending Payment Verification | AE Electric | General Wiring |
| 07/14/2026 | Pending Payment Verification | AE Electric | General Wiring |
| 07/10/2026 | Pending Payment Verification | AE Electric | General Wiring |
| 10/22/2023 | Complete | AE Electric | General Wiring |
| 05/22/2023 | Complete | Richard Neu | — |
| 02/27/2023 | Permit Issued | 5 J'S Electl Conts | General Wiring |
| 11/22/2022 | Complete | 5 J'S Electl Conts | — |
| Filed | Status | Contractor | Scope |
|---|---|---|---|
| 01/27/2026 | Signed-off | JJS Management | Steel, Masonry, Wood |
| Date | Type | Result | Report |
|---|---|---|---|
| 10/08/2026 | Pass-Final PL - Up to 9 Requested Floors | Pass | View ↗ |
| 04/22/2026 | Pass-Final CND-Occupancy Inspection | Pass | View ↗ |
| 02/18/2026 | Certified Sprinkler-SP-Piping Dry/Wet-Hydrostatic Test | Certified | View ↗ |
| 01/23/2026 | Fail-Final PL - Up to 3 Requested Floors | Fail | View ↗ |
| 12/24/2025 | Certified Sprinkler-SP-Fixtures-Finish | Certified | View ↗ |
| 12/03/2025 | Fail-Final PL - Up to 3 Requested Floors | Fail | View ↗ |
| 02/26/2024 | Pass-Final PL - Up to 9 Requested Floors | Pass | View ↗ |
| Date | Requirement | Inspector | Role |
|---|---|---|---|
| 02/10/2026 | Post-installed Anchors | Alexander Sheyman | special |
| 02/10/2026 | Fire-Resistant Penetrations and Joints | Alexander Sheyman | special |
| 02/10/2026 | Seismic Resistance of Plumbing, Mechanical, Fuel Gas, and Electrical Components | Alexander Sheyman | special |
| 01/26/2026 | Fire-Resistant Penetrations and Joints | Alexander Sheyman | special |
| 01/26/2026 | Post-installed Anchors | Alexander Sheyman | special |
| 01/26/2026 | Seismic Resistance of Plumbing, Mechanical, Fuel Gas, and Electrical Components | Alexander Sheyman | special |
| 03/20/2025 | Sprinkler Systems | Alexander Sheyman | special |
| 03/20/2025 | Post-installed Anchors | Alexander Sheyman | special |
| 03/20/2025 | Seismic Isolation Systems | Alexander Sheyman | special |
| 03/20/2025 | Fire-Resistant Penetrations and Joints | Alexander Sheyman | special |
| 03/05/2025 | Seismic Isolation Systems | Alexander Sheyman | special |
| 03/05/2025 | Sprinkler Systems | Alexander Sheyman | special |
| 03/05/2025 | Fire-Resistant Penetrations and Joints | Alexander Sheyman | special |
| 03/05/2025 | Post-installed Anchors | Alexander Sheyman | special |
| 09/19/2024 | Energy Code Compliance Inspections | Alexander Sheyman | progress |
| 09/19/2024 | Fire-Resistant Penetrations and Joints | Alexander Sheyman | special |
| 01/03/2024 | Energy Code Compliance Inspections | Alexander Sheyman | progress |
| 01/03/2024 | Fire-Resistant Penetrations and Joints | Alexander Sheyman | special |
| 10/31/2023 | Structural Cold-Formed Steel | William DeGraaff | special |
| 10/25/2023 | Post-installed Anchors | William DeGraaff | special |
| 10/25/2023 | Structural Steel - High Strength Bolting | William DeGraaff | special |
| 10/25/2023 | Structural Stability – Alterations of existing buildings | William DeGraaff | special |
| 10/24/2023 | Structural Steel - Details | William DeGraaff | special |
| 10/24/2023 | Masonry | William DeGraaff | special |
| 07/19/2023 | Final | William DeGraaff | progress |