1920Year Built
2Stories
A1Building Class
R4-1Zoning
1,862 sfGross Floor Area
1Units
Two stories - detached, small or mid-size · 2,500 sf lot · 0.74 FAR built · Flood zone X
Locations of Work
ArchitecturePlumbingGeneral
Floor 22p · 2 filings · 20 docs
Floor 12p · 2 filings · 20 docs
Cellar5p · 2 filings · 20 docs
▾Sales History (ACRIS)
DatePriceUnitSeller → Buyer$/sf
03/06/2023$1.1M—— → —$591/sf building
▾Design Consultants (Architect / Engineer of Record)
FirmFilingsMost Recent
JUST CONSULTING ENGINEERING609/28/2023
▾Filing Representatives (Expediters)
RepresentativeFilingsMost Recent
ECDESIGN STUDIO1203/21/2026
▾Contractors (License-Anchored)
FirmTradeRolesMost Recent
FOWA INTERIOR CORPGeneral Contractor107/08/2026
JOHN FITZGERALD PLBG &HTGPlumbing107/08/2026
▾Special Inspection Agencies
AgencyLicense #FilingsMost Recent
G ENGINEERING PC7778209/20/2023
Building Lifecycle
All (19)Filed (6)Permit Issued (2)Signed Off (2)Inspection (5)Special Inspection (4)
10/18/2023
Signed off — Alteration
RENOVATION OF EXISTING CELLAR, FIRST AND SECOND FLOOR WITH GENERAL CONSTRUCTION: NEW PARTITIONS, DOORS, FLOORING AND COSMETIC WORK; NO CHANGE IN USE, EGRESS OR OCCUPANCY UNDER THIS APPLICATION.
B00852563-I1
10/18/2023
Signed off — Alteration
RENOVATION OF EXISTING CELLAR, FIRST AND SECOND FLOOR WITH PLUMBING WORK:REPLACE KITCHEN AND BATHROOM FIXTURES; REPLACE HOT WATER HEATERS ON CELLAR; NO CHANGE IN USE, EGRESS OR OCCUPANCY UNDER THIS APPLICATION.
B00852007-I1
10/11/2023
Inspection — Pass-Final General Construction Non-Directive 14
Pass
View inspection ↗
10/03/2023
Inspection — Fail-Final General Construction Non-Directive 14
Fail
View inspection ↗
09/28/2023
Filed — Alteration
RENOVATION OF EXISTING CELLAR, FIRST AND SECOND FLOOR WITH PLUMBING WORK:REPLACE KITCHEN AND BATHROOM FIXTURES; REPLACE HOT WATER HEATERS ON CELLAR; NO CHANGE IN USE, EGRESS OR OCCUPANCY UNDER THIS APPLICATION.
B00852007-P4
09/22/2023
Special inspection requirement — Mechanical Systems
XIONGCAI GU
09/22/2023
Special inspection requirement — Final
XIONGCAI GU
09/20/2023
Filed — Alteration
RENOVATION OF EXISTING CELLAR, FIRST AND SECOND FLOOR WITH GENERAL CONSTRUCTION: NEW PARTITIONS, DOORS, FLOORING AND COSMETIC WORK; NO CHANGE IN USE, EGRESS OR OCCUPANCY UNDER THIS APPLICATION.
B00852563-P1
09/20/2023
Filed — Alteration
RENOVATION OF EXISTING CELLAR, FIRST AND SECOND FLOOR WITH PLUMBING WORK:REPLACE KITCHEN AND BATHROOM FIXTURES; REPLACE HOT WATER HEATERS ON CELLAR; NO CHANGE IN USE, EGRESS OR OCCUPANCY UNDER THIS APPLICATION.
B00852007-P3
09/20/2023
Special inspection requirement — Mechanical Systems
XIONGCAI GU
09/20/2023
Special inspection requirement — Final
XIONGCAI GU
05/10/2023
Inspection — Certified Water and Sanitary-WS-Fixtures-Finish
Certified
View inspection ↗
05/05/2023
Inspection — Certified Water and Sanitary-WS-Sanitary Piping-Roughing
Certified
View inspection ↗
05/05/2023
Inspection — Certified Water and Sanitary-WS-Sanitary Piping-Underground
Certified
View inspection ↗
04/24/2023
Permit issued — Plumbing
B00852007-I1-PL
04/10/2023
Permit issued — General Construction
B00852563-I1-GC-CX
04/04/2023
Filed — Alteration
RENOVATION OF EXISTING CELLAR, FIRST AND SECOND FLOOR WITH PLUMBING WORK:REPLACE KITCHEN AND BATHROOM FIXTURES; REPLACE HOT WATER HEATERS ON CELLAR; NO CHANGE IN USE, EGRESS OR OCCUPANCY UNDER THIS APPLICATION.
B00852007-P1
03/30/2023
Filed — Alteration
RENOVATION OF EXISTING CELLAR, FIRST AND SECOND FLOOR WITH GENERAL CONSTRUCTION: NEW PARTITIONS, DOORS, FLOORING AND COSMETIC WORK; NO CHANGE IN USE, EGRESS OR OCCUPANCY UNDER THIS APPLICATION.
B00852563-I1
03/30/2023
Filed — Alteration
RENOVATION OF EXISTING CELLAR, FIRST AND SECOND FLOOR WITH PLUMBING WORK:REPLACE KITCHEN AND BATHROOM FIXTURES; REPLACE HOT WATER HEATERS ON CELLAR; NO CHANGE IN USE, EGRESS OR OCCUPANCY UNDER THIS APPLICATION.
B00852007-I1
Permit / Filing Register
SourceWork TypeStatusApplicantIssued
DOB NOWPlumbingSigned-offJOHN FITZGERALD PLBG &HTG04/24/2023
DOB NOWGeneral ConstructionSigned-offFOWA INTERIOR CORP04/10/2023
1 project · most recent 03/28/2023
General Wiring
FiledStatusContractorScope
03/28/2023CompleteHI-RITE ELECTRIC CORPGeneral Wiring
▾Field Inspections (DOB CAP) — 5
DateTypeResultReport
10/11/2023Pass-Final General Construction Non-Directive 14PassView ↗
10/03/2023Fail-Final General Construction Non-Directive 14FailView ↗
05/10/2023Certified Water and Sanitary-WS-Fixtures-FinishCertifiedView ↗
05/05/2023Certified Water and Sanitary-WS-Sanitary Piping-RoughingCertifiedView ↗
05/05/2023Certified Water and Sanitary-WS-Sanitary Piping-UndergroundCertifiedView ↗
▾Special Inspection Requirements (DOB NOW) — 4
DateRequirementInspectorRole
09/22/2023Mechanical SystemsXIONGCAI GUspecial
09/22/2023FinalXIONGCAI GUprogress
09/20/2023Mechanical SystemsXIONGCAI GUspecial
09/20/2023FinalXIONGCAI GUprogress
▾Documents — 21 on file (BIS + DOB NOW)
▸Plans & Drawings6
▸DOB NOWPlans/Sketch6
08/27/2026B00852007-I1Request digital key ↗
08/27/2026B00852007-P4Request digital key ↗
08/27/2026B00852007-P3Request digital key ↗
Showing 3 of 6 on file for this type
▸Zoning, Tax Lot & Property Records5
▸DOB NOWRestrictive Declaration/Easement 15
08/13/2026B00852563-I1Open ↗
08/13/2026B00852007-P3Open ↗
08/13/2026B00852563-P1Open ↗
Showing 3 of 5 on file for this type
▸Seals & Professional Certifications10
▸DOB NOWDPL-1: Design Professional Seal & Signature6
08/27/2026B00852007-P4Open ↗
08/27/2026B00852007-P3Open ↗
08/27/2026B00852007-P1Open ↗
Showing 3 of 6 on file for this type
▸DOB NOWProgress Inspector Seal & Signature2
08/27/2026B00852563-P1Open ↗
08/25/2026B00852563-I1Open ↗
▸DOB NOWSpecial Inspector Seal & Signature2
08/27/2026B00852563-P1Open ↗
08/25/2026B00852563-I1Open ↗