← Back
Two family frame
4388 RICHARDSON AVENUE
BRONX · Wakefield-Woodlawn · BIN 2069775
💬 Discuss this project
1920Year Built
2Stories
B2Building Class
R5AZoning
1,766 sfGross Floor Area
2Units
3 Open Violations ▸FDNY Report ↗
Two family frame · 2,625 sf lot · 0.67 FAR built · Flood zone X
Locations of Work
ArchitectureGeneral
Filed — no permit issued11p · 1 filing · 7 docs
▾Sales History (ACRIS)
DatePriceUnitSeller → Buyer$/sf
12/27/2017$540K—— → —$306/sf building
▾Design Consultants (Architect / Engineer of Record)
FirmFilingsMost Recent
NY BUILDING ASSOCIATES INC110/25/2024
▾Filing Representatives (Expediters)
RepresentativeFilingsMost Recent
SUNCO CAPITAL203/21/2026
▾Special Inspection Agencies
AgencyLicense #FilingsMost Recent
NKM ENGINEERING PLLC6244110/25/2024
Building Lifecycle
All (7)Filed (1)Special Inspection (6)
10/25/2024
Filed — Alteration
INSTALLATION OF SOLAR PANELS ON ROOF. NO CHANGE IN USE, EGRESS, OR OCCUPANCY.
X01116841-I1
09/25/2024
Special inspection requirement — Fire-Resistant Penetrations and Joints
NARESH MAHANGU
09/25/2024
Special inspection requirement — Structural Stability – Alterations of existing buildings
NARESH MAHANGU
09/25/2024
Special inspection requirement — Flood Zone Compliance (attach FEMA elevation/dry floodproofing certificate where applicable)
NARESH MAHANGU
09/25/2024
Special inspection requirement — Energy Code Compliance Inspections
NARESH MAHANGU
09/25/2024
Special inspection requirement — Final
NARESH MAHANGU
09/25/2024
Special inspection requirement — Air barrier - visual inspection
NARESH MAHANGU
Nothing on file for this building.
1 project · most recent 10/03/2024
FiledStatusContractorScope
10/03/2024Permit IssuedBERGER QUALITY ELEC'L CON—
1 project · most recent 10/25/2024
FiledStatusContractorScope
10/25/2024——19 panels, 7.98 kw, 1,103 roof_area_sqft
▾Special Inspection Requirements (DOB NOW) — 6
DateRequirementInspectorRole
09/25/2024Fire-Resistant Penetrations and JointsNARESH MAHANGUspecial
09/25/2024Structural Stability – Alterations of existing buildingsNARESH MAHANGUspecial
09/25/2024Flood Zone Compliance (attach FEMA elevation/dry floodproofing certificate where applicable)NARESH MAHANGUspecial
09/25/2024Energy Code Compliance InspectionsNARESH MAHANGUprogress
09/25/2024FinalNARESH MAHANGUprogress
09/25/2024Air barrier - visual inspectionNARESH MAHANGUenergy_progress
▾Documents — 7 on file (BIS + DOB NOW)
▸Plans & Drawings1
▸DOB NOWPlans/Sketch1
08/20/2026X01116841-I1Request digital key ↗
▸Seals & Professional Certifications5
▸DOB NOWProgress Inspector Seal & Signature2
08/26/2026X01116841-I1Open ↗
08/26/2026X01116841-I1Open ↗
▸DOB NOWSpecial Inspector Seal & Signature2
08/26/2026X01116841-I1Open ↗
08/26/2026X01116841-I1Open ↗
▸DOB NOWDPL-1: Design Professional Seal & Signature1
08/13/2026X01116841-I1Open ↗
▸Environmental & Asbestos1
▸DOB NOWDEP ACP-5: Asbestos Assessment Report1
08/13/2026X01116841-I1Open ↗