← Back
One family attached or semi-detached
439 5 STREET
BROOKLYN · BIN 3021310
💬 Discuss this project
1901Year Built
3Stories
A5Building Class
R6BZoning
3,413 sfGross Floor Area
1Units
0 Open ViolationsFDNY Report ↗
One family attached or semi-detached · Owner of record: CELESTIAL CAROUSEL, LLC · 1,750 sf lot · 1.95 FAR built · Flood zone X
Locations of Work
ArchitectureStructuralGeneral
Roof3p · 2 filings · 20 docs
Penthouse1p · 1 filing · 20 docs
Floor 25p · 2 filings · 20 docs
Floor 14p · 1 filing · 3 docs
Cellar4p · 1 filing · 3 docs
Basement2p · 1 filing · 20 docs
Sub-Basement4p · 1 filing · 3 docs
▾Owner History (Filing Record)
Companies and organizations named on filings. Individual owners are not shown.
OwnerFilingsMost Recent
MINERVA2507/08/2026
NYC BUILDING SOLUTIONS CO103/22/2026
▾Sales History (ACRIS)
DatePriceUnitSeller → Buyer$/sf
10/04/2024$5.9M—439 PS LLC → CELESTIAL CAROUSEL, LLC$1,729/sf building
10/12/2022$2.0M—— → —$601/sf building
▾Design Consultants (Architect / Engineer of Record)
FirmFilingsMost Recent
CHUN ENGINEERING CONSULTANT PLLC502/19/2024
DOYUN KIM; RA311/29/2023
FABIAN CRUZ PE PLLC109/18/2023
ASHRAF CORP205/22/2023
RAS PE CONSULTING ENGINEERS302/28/2023
▾Filing Representatives (Expediters)
RepresentativeFilingsMost Recent
NYC BUILDING SOLUTIONS1103/21/2026
DANICO SERVICES403/21/2026
▾Contractors (License-Anchored)
FirmTradeRolesMost Recent
NYC BUILDING SOLUTIONS COGeneral Contractor1007/08/2026
LAKHI GENERAL CONTRACTORGeneral Contractor307/08/2026
RRP PLUMBING CORPFire Protection107/08/2026
RRP PLUMBING CORPPlumbing107/08/2026
▾Special Inspection Agencies
AgencyLicense #FilingsMost Recent
DOYUN KIM; RA74151102/19/2024
Building Lifecycle
All (115)Filed (14)Permit Issued (9)Signed Off (8)Violation (1)Inspection (11)Objection (42)Special Inspection (30)
02/23/2024
Signed off — Alteration
HEREWITH FILING TO INSTALL PLUMBING FIXTURES AS PER CONSTRUCTION PLANS. IN CONJUNCTION WITH DOB JOB #B08046796.
B00800260-I1
02/20/2024
Special inspection requirement — Fire-Resistant Penetrations and Joints
DOYUN KIM
02/20/2024
Special inspection requirement — Energy Code Compliance Inspections
DOYUN KIM
02/19/2024
Filed — Alteration
HEREWITH FILING TO INSTALL PLUMBING FIXTURES AS PER CONSTRUCTION PLANS. IN CONJUNCTION WITH DOB JOB #B08046796.
B00800260-P2
02/12/2024
Signed off — Alteration
B08052772-I1
02/12/2024
Filed — Alteration
HEREWITH FILING TO INSTALL PLUMBING FIXTURES AS PER CONSTRUCTION PLANS. IN CONJUNCTION WITH DOB JOB #B08046796.
B00800260-P1
02/09/2024
Special inspection requirement — Energy Code Compliance Inspections
DOYUN KIM
02/09/2024
Special inspection requirement — Fire-Resistant Penetrations and Joints
DOYUN KIM
02/08/2024
Inspection — Certified Sprinkler-SP-Fixtures-Finish
Certified
View inspection ↗
02/02/2024
Inspection — Certified Sprinkler-SP-Piping Dry/Wet-Hydrostatic Test
Certified
View inspection ↗
01/30/2024
Objection resolved — Addressed
01/17/2024
Signed off — Alteration
INSTALLATION OF 8 F.T. TEMPORARY WOOD CONSTRUCTION FENCE.
B00819081-I1
01/05/2024
Objection resolved — Addressed
01/05/2024
Objection resolved — Addressed
01/05/2024
Objection resolved — Addressed
12/28/2023
Inspection — Pass-Final Construction Permit Withdrawal
Pass
View inspection ↗
12/19/2023
Objection raised — Other
12/19/2023
Objection raised — Other
12/19/2023
Objection raised — Other
12/19/2023
Objection raised — Other
12/18/2023
Inspection — Fail-Final Construction Permit Withdrawal
Fail
View inspection ↗
12/08/2023
Objection resolved — Addressed
12/07/2023
Objection resolved — Addressed
12/07/2023
Objection resolved — Addressed
12/07/2023
Objection resolved — Addressed
12/07/2023
Objection resolved — Addressed
12/04/2023
Inspection — Fail-Final Construction Permit Withdrawal
Fail
View inspection ↗
12/04/2023
Objection raised — Other
12/04/2023
Objection raised — Other
12/04/2023
Objection raised — Other
12/04/2023
Objection raised — Other
12/04/2023
Objection raised — Other
11/29/2023
Filed — Alteration CO
HEREWITH FILING FOR FOUNDATION AND EARTHWORK FOR ALTERATION-1 BUILDING FOR EXTENSION IN BACKYARD SUBSEQUENT TO ARCHITECT APPLICATION B08046800-I1
B08046800-P2
09/22/2023
Permit issued — Sprinklers
B08052772-I1-EW-SP
09/20/2023
Signed off — Alteration
INSTALLATION OF TEMPORARY PIPE SCAFFOLD AS PER DRAWINGS. PIPE SCAFFOLD SHALL COMPLY WITH CHAPTER # 33 OF THE 2022 NYC BUILDING CODE. NO CHANGE IN USE, OCCUPANCY OR EGRESS UNDER THIS APPLICATION.
B00878602-I1
09/20/2023
Signed off — Alteration CO
HEREWITH FILING FOR FOUNDATION AND EARTHWORK FOR ALTERATION-1 BUILDING FOR EXTENSION IN BACKYARD SUBSEQUENT TO ARCHITECT APPLICATION B08046800-I1
B08046800-S1
09/18/2023
Filed — Alteration
B08052772-I1
09/01/2023
Signed off — Alteration
HEAVY DUTY SIDEWALK SHED AS PER PLANS. NO CHANGE IN USE, EGRESS OR OCCUPANCY UNDER THIS APPLICATION. SIDEWALK SHED SHALL COMPLY WITH CHAPTER 33 OF THE 2022 BUIILDING CODE.
B00877881-I1
08/17/2023
Inspection — Certified Gas-Gas-Piping-Roughing
Certified
View inspection ↗
08/17/2023
Inspection — Certified Storm Drainage-ST-Piping-Roughing
Certified
View inspection ↗
08/17/2023
Inspection — Certified Storm Drainage-ST-Piping-Underground
Certified
View inspection ↗
08/17/2023
Inspection — Certified Water and Sanitary-WS-Sanitary Piping-Roughing
Certified
View inspection ↗
08/15/2023
Inspection — Certified Remove/Cap - work done in accordance with code
Certified
View inspection ↗
06/26/2023
Violation issued (ECB, closed)
Construction
06/20/2023
Permit issued — Plumbing
B00800260-I1-PL
06/12/2023
Filed — Alteration
HEREWITH FILING TO INSTALL PLUMBING FIXTURES AS PER CONSTRUCTION PLANS. IN CONJUNCTION WITH DOB JOB #B08046796.
B00800260-I1
06/06/2023
Filed — Alteration CO
HEREWITH FILING FOR FOUNDATION AND EARTHWORK FOR ALTERATION-1 BUILDING FOR EXTENSION IN BACKYARD SUBSEQUENT TO ARCHITECT APPLICATION B08046800-I1
B08046800-P1
06/02/2023
Signed off — Alteration CO
HEREWITH FILING FOR FOUNDATION AND EARTHWORK FOR ALTERATION-1 BUILDING FOR EXTENSION IN BACKYARD SUBSEQUENT TO ARCHITECT APPLICATION B08046800-I1
B08046800-S2
06/02/2023
Special inspection requirement — Fire-Resistant Penetrations and Joints
DOYUN KIM
06/02/2023
Special inspection requirement — Masonry
DOYUN KIM
06/02/2023
Special inspection requirement — Mechanical Systems
DOYUN KIM
06/02/2023
Special inspection requirement — Structural Stability – Alterations of existing buildings
DOYUN KIM
06/02/2023
Special inspection requirement — Structural Steel - Details
DOYUN KIM
06/02/2023
Special inspection requirement — Structural Steel - High Strength Bolting
DOYUN KIM
06/02/2023
Special inspection requirement — Structural Steel - Welding
DOYUN KIM
06/02/2023
Special inspection requirement — Energy Code Compliance Inspections
DOYUN KIM
06/02/2023
Special inspection requirement — Final
DOYUN KIM
06/02/2023
Special inspection requirement — Fire-Resistance Rated Construction
DOYUN KIM
06/02/2023
Special inspection requirement — Footing and Foundation
DOYUN KIM
06/02/2023
Special inspection requirement — Lowest Floor Elevation
DOYUN KIM
Latest 60 of 115 events.
Permit / Filing Register
SourceWork TypeStatusApplicantIssued
DOB NOWSprinklersSigned-offRALPH W. LANDOLFI JR.09/22/2023
DOB NOWPlumbingSigned-offRRP PLUMBING CORP06/20/2023
DOB NOWFoundationSigned-offNYC BUILDING SOLUTIONS CO05/30/2023
DOB NOWSidewalk ShedSigned-offLAKHI GENERAL CONTRACTOR05/23/2023
DOB NOWSupported ScaffoldSigned-offLAKHI GENERAL CONTRACTOR05/23/2023
DOB NOWSupport of ExcavationSigned-offNYC BUILDING SOLUTIONS CO04/28/2023
DOB NOWStructuralSigned-offNYC BUILDING SOLUTIONS CO04/20/2023
DOB NOWConstruction FenceSigned-offNYC BUILDING SOLUTIONS CO01/31/2023
DOB NOWGeneral ConstructionPermit IssuedNYC BUILDING SOLUTIONS CO01/09/2023
1 project · most recent 11/29/2023
Air Conditioning Systems Heating Systems
FiledStatusContractorScopeMake / Model / Capacity
11/29/2023Signed-offNYC BUILDING SOLUTIONS COAir Conditioning Systems, Heating Systems
Cooling
Mitsubishi Electric MXZ-3C30NA 27,400 BTU · Condensing Unit ×12
Heating
Mitsubishi Electric MXZ-3C30NA 27,600 BTU · Condensing Unit ×4
— MXZ-3C30NA 27,600 BTU · Condensing Unit ×8
1 project · most recent 06/14/2023
General Wiring
FiledStatusContractorScope
06/14/2023CompleteLENS ELECTRIC, INCGeneral Wiring
1 project · most recent 11/29/2023
Steel Concrete Masonry Wood
FiledStatusContractorScope
11/29/2023Signed-offNYC BUILDING SOLUTIONS COSteel, Concrete, Masonry, Wood
▾Field Inspections (DOB CAP) — 11
DateTypeResultReport
02/08/2024Certified Sprinkler-SP-Fixtures-FinishCertifiedView ↗
02/02/2024Certified Sprinkler-SP-Piping Dry/Wet-Hydrostatic TestCertifiedView ↗
12/28/2023Pass-Final Construction Permit WithdrawalPassView ↗
12/18/2023Fail-Final Construction Permit WithdrawalFailView ↗
12/04/2023Fail-Final Construction Permit WithdrawalFailView ↗
08/17/2023Certified Gas-Gas-Piping-RoughingCertifiedView ↗
08/17/2023Certified Storm Drainage-ST-Piping-RoughingCertifiedView ↗
08/17/2023Certified Storm Drainage-ST-Piping-UndergroundCertifiedView ↗
08/17/2023Certified Water and Sanitary-WS-Sanitary Piping-RoughingCertifiedView ↗
08/15/2023Certified Remove/Cap - work done in accordance with codeCertifiedView ↗
02/01/2023Pass-Final CND-Occupancy InspectionPassView ↗
▾Special Inspection Requirements (DOB NOW) — 45
DateRequirementInspectorRole
02/20/2024Fire-Resistant Penetrations and JointsDOYUN KIMspecial
02/20/2024Energy Code Compliance InspectionsDOYUN KIMprogress
02/09/2024Energy Code Compliance InspectionsDOYUN KIMprogress
02/09/2024Fire-Resistant Penetrations and JointsDOYUN KIMspecial
06/02/2023Fire-Resistant Penetrations and JointsDOYUN KIMspecial
06/02/2023MasonryDOYUN KIMspecial
06/02/2023Mechanical SystemsDOYUN KIMspecial
06/02/2023Structural Stability – Alterations of existing buildingsDOYUN KIMspecial
06/02/2023Structural Steel - DetailsDOYUN KIMspecial
06/02/2023Structural Steel - High Strength BoltingDOYUN KIMspecial
06/02/2023Structural Steel - WeldingDOYUN KIMspecial
06/02/2023Energy Code Compliance InspectionsDOYUN KIMprogress
06/02/2023FinalDOYUN KIMprogress
06/02/2023Fire-Resistance Rated ConstructionDOYUN KIMprogress
06/02/2023Footing and FoundationDOYUN KIMprogress
06/02/2023Lowest Floor ElevationDOYUN KIMprogress
06/02/2023Air barrier - visual inspectionDOYUN KIMenergy_progress
06/02/2023Interior lighting powerDOYUN KIMenergy_progress
06/02/2023Exterior lighting powerDOYUN KIMenergy_progress
06/02/2023Fenestration and door U-factor and product ratingsDOYUN KIMenergy_progress
06/02/2023HVAC-R and service water heating system controlsDOYUN KIMenergy_progress
06/02/2023Lighting controlsDOYUN KIMenergy_progress
06/02/2023Fenestration air leakageDOYUN KIMenergy_progress
06/02/2023Fenestration areasDOYUN KIMenergy_progress
06/02/2023HVAC-R and service water piping design and insulationDOYUN KIMenergy_progress
Latest 25 of 45.
▾Documents — 87 on file (BIS + DOB NOW)
▸Plans & Drawings14
▸DOB NOWPlans/Sketch14
08/28/2026B08046796-I1Request digital key ↗
08/27/2026B00819081-I1Request digital key ↗
08/27/2026B08046800-P1Request digital key ↗
Showing 3 of 14 on file for this type
▸Zoning, Tax Lot & Property Records4
▸DOB NOWZD1: DOB Zoning Diagram3
08/13/2026B08046800-P1Open ↗
08/13/2026B08046800-P2Open ↗
08/13/2026B08046800-I1Open ↗
▸DOB NOWHouse Number Verification: TOPO Stamp1
08/13/2026B08046800-I1Open ↗
▸Seals & Professional Certifications27
▸DOB NOWDPL-1: Design Professional Seal & Signature14
08/27/2026B00819081-I1Open ↗
08/27/2026B08046800-S2Open ↗
08/27/2026B08046800-S3Open ↗
Showing 3 of 14 on file for this type
▸DOB NOWSpecial Inspector Seal & Signature8
08/31/2026B00800260-P1Open ↗
08/29/2026B00800260-I1Open ↗
08/26/2026B08046800-P1Open ↗
Showing 3 of 8 on file for this type
▸DOB NOWProgress Inspector Seal & Signature5
08/31/2026B00800260-P1Open ↗
08/29/2026B00800260-I1Open ↗
08/26/2026B08046800-P1Open ↗
Showing 3 of 5 on file for this type
▸Trade Schedules & Equipment3
▸DOB NOWDEP: Sewer Certification (Sanitary/Storm)3
08/13/2026B08046800-P2Open ↗
08/13/2026B08046800-P1Open ↗
08/13/2026B08046800-I1Open ↗
▸Safety & Tenant Protection6
▸DOB NOWStreet Tree Checklist3
08/27/2026B08046800-P1Open ↗
08/27/2026B08046800-I1Open ↗
08/14/2026B08046800-P2Open ↗
▸DOB NOWStreet Trees Site Plan1
08/13/2026B08046800-I1Open ↗
▸DOB NOWParks Department Acknowledgment Letter for Street Trees Plan1
08/13/2026B08046800-I1Open ↗
▸DOB NOWStreet Tree Sign Off1
08/13/2026B08046800-I1Open ↗
▸Environmental & Asbestos11
▸DOB NOWDEP ACP-5: Asbestos Assessment Report11
08/27/2026B08046800-P1Open ↗
08/27/2026B08046800-I1Open ↗
08/27/2026B00800260-P2Open ↗
Showing 3 of 11 on file for this type
▸Inspections & Test Reports4
▸DOB NOWTR4 Test Report and Plot Diagram2
08/13/2026B08046800-S3Open ↗
08/13/2026B08046800-S2Open ↗
▸DOB NOWSOIL REPORT2
08/13/2026B08046800-S3Open ↗
08/13/2026B08046800-S2Open ↗
▸Other Documents18
▸DOB NOWPlot Diagram5
08/13/2026B08046800-I1Open ↗
08/13/2026B08046800-S3Open ↗
08/13/2026B08046800-P1Open ↗
Showing 3 of 5 on file for this type
▸DOB NOWAdjoining Owners Notification3
08/13/2026B08046800-I1Open ↗
08/13/2026B08046800-S2Open ↗
08/13/2026B08046800-S3Open ↗
▸DOB NOWSite Survey: Initial3
08/13/2026B08046800-P2Open ↗
08/13/2026B08046800-P1Open ↗
08/13/2026B08046800-I1Open ↗
▸DOB NOWLocal Law 92/94 of 2019 Sustainable Roof Zone3
08/13/2026B08046800-I1Open ↗
08/13/2026B08046800-P2Open ↗
08/13/2026B08046800-P1Open ↗
▸DOB NOWProperty Ownership Certification3
08/27/2026B08046800-P1Open ↗
08/27/2026B08046800-I1Open ↗
08/14/2026B08046800-P2Open ↗
▸DOB NOWFinal Survey1
08/13/2026B08046800-I1Open ↗