← Back
Condo, residential unit in 2-10 unit building
44 MORTON STREET
MANHATTAN · BIN 1077348
💬 Discuss this project
1845Year Built
3Stories
R1Building Class
R6Zoning
3,355 sfGross Floor Area
5Units
Rent Stabilized0 Open Violations
Condo, residential unit in 2-10 unit building · Owner of record: 44 MORTON STREET CONDOMINIUM · 1,754 sf lot · 1.91 FAR built · Flood zone X500
Locations of Work
ArchitectureGeneral
Roof3p · 1 filing · 8 docs
▾Owner History (Filing Record)
Companies and organizations named on filings. Individual owners are not shown.
OwnerFilingsMost Recent
ZKW ENTERPRISES407/08/2026
J G CONSTRUCTION SRVCS604/09/2026
44 MORTON STREET CONDOMIN103/22/2026
DK103/22/2026
▾Design Consultants (Architect / Engineer of Record)
FirmFilingsMost Recent
VAIL ASSOCIATES ARCHITECTS505/01/2026
KMA DESIGNS LLC105/09/2025
ASR ENGINEERING PC107/27/2022
TING-I KANG ARCHITECT104/11/2022
▾Filing Representatives (Expediters)
RepresentativeFilingsMost Recent
KMA DESIGNS LLC203/21/2026
ADVANCED BUILDERS SERVICES103/21/2026
MODERN BUILDING CONSULTANT103/21/2026
▾Contractors (License-Anchored)
FirmTradeRolesMost Recent
J & G CONSTRUCTION SVCSGeneral Contractor404/09/2026
R.J.C. MECHANICAL CORPPlumbing303/22/2026
DWG SERVICES INCGeneral Contractor303/21/2026
Z.W. PLBG & HTG CORPPlumbing207/08/2026
LUBAN INCGeneral Contractor203/21/2026
APOLLO ELECTRIC USA, INCElectrical103/22/2026
ZKW ENTERPRISES INCGeneral Contractor107/08/2026
AIRPROS, INCGeneral Contractor104/09/2026
HIICOMPANY CORPGeneral Contractor104/09/2026
▾Special Inspection Agencies
AgencyLicense #FilingsMost Recent
VAIL ASSOCIATES ARCHITECT4315210/06/2025
GREAT WALL CONSULTANT P.E5633104/11/2022
Building Lifecycle
All (54)Filed (8)Permit Issued (8)Signed Off (3)Violation (7)Inspection (5)Objection (10)Special Inspection (13)
06/18/2026
Signed off — Alteration
ALT 2. PROPOSE INTERIOR RENOVATION WITH PARTITIONS, FLOOR FINISH & PLUMBING & MS WORK AS PER PLAN. NO CHANGE IN USE, EGRESS & OCCUPANCY.
M01193788-S1
06/15/2026
Signed off — Alteration
ALT 2. PROPOSE INTERIOR RENOVATION WITH PARTITIONS, FLOOR FINISH & PLUMBING & MS WORK AS PER PLAN. NO CHANGE IN USE, EGRESS & OCCUPANCY.
M01193788-I1
05/26/2026
Special inspection requirement — Energy Code Compliance Inspections
Thomas Vail
05/01/2026
Filed — Alteration
ALT 2. PROPOSE INTERIOR RENOVATION WITH PARTITIONS, FLOOR FINISH & PLUMBING & MS WORK AS PER PLAN. NO CHANGE IN USE, EGRESS & OCCUPANCY.
M01193788-P2
04/14/2026
Inspection — Certified Water and Sanitary-WS-Fixtures-Finish
Certified
View inspection ↗
04/10/2026
Inspection — Pass-Final PL - Up to 3 Requested Floors
Pass
View inspection ↗
03/16/2026
Filed — Alteration
ALT 2. PROPOSE INTERIOR RENOVATION WITH PARTITIONS, FLOOR FINISH & PLUMBING & MS WORK AS PER PLAN. NO CHANGE IN USE, EGRESS & OCCUPANCY.
M01193788-P1
03/13/2026
Special inspection requirement — Energy Code Compliance Inspections
Thomas Vail
03/11/2026
Inspection — Pass-Final PL - Up to 3 Requested Floors
Pass
View inspection ↗
12/04/2025
Signed off — Alteration
installation of heavy duty sidewalk shed and pipe scaffolding. no change in use, occupancy or egress. work shall comply with chapter 33 of nycbc.
M01218303-I1
11/12/2025
Permit issued — General Construction
M01193788-I1-MS
10/31/2025
Inspection — Certified Water and Sanitary-WS-Sanitary Piping-Roughing
Certified
View inspection ↗
10/29/2025
Inspection — Certified Water and Sanitary-WS-Sanitary Piping-Roughing
Certified
View inspection ↗
10/06/2025
Filed — Alteration
ALT 2. NEW AC UNITS FOR AIR_CONDITIONING. NO CHANGE IN USE, EGRESS OR OCCUPANCY.
M01265412-I1
10/06/2025
Permit issued — Plumbing
M01193788-S1-PL
10/04/2025
Special inspection requirement — Duct leakage testing, insulation and design
Thomas Vail
08/12/2025
Violation issued (ECB, closed)
Construction
08/12/2025
Violation issued (ECB, closed)
Unknown
08/12/2025
Violation issued (ECB, closed)
Construction
08/08/2025
Permit issued — General Construction
M01193788-I1-MS
08/05/2025
Permit issued — Mechanical Systems
M01193788-I1-GC
08/04/2025
Objection resolved — Addressed
08/01/2025
Objection resolved — Addressed
08/01/2025
Special inspection requirement — Final
Thomas Vail
08/01/2025
Special inspection requirement — Mechanical Systems
Thomas Vail
07/16/2025
Objection resolved — Addressed
07/09/2025
Objection raised — Scope
07/09/2025
Objection raised — Scope
06/16/2025
Filed — Alteration
ALT 2. PROPOSE INTERIOR RENOVATION WITH PARTITIONS, FLOOR FINISH & PLUMBING & MS WORK AS PER PLAN. NO CHANGE IN USE, EGRESS & OCCUPANCY.
M01193788-S1
06/16/2025
Objection resolved — Addressed
06/16/2025
Objection resolved — Addressed
06/05/2025
Objection raised — Cost
06/05/2025
Objection raised — Admin
06/05/2025
Objection raised — Admin
05/21/2025
Filed — Alteration
ALT 2. PROPOSE INTERIOR RENOVATION WITH PARTITIONS, FLOOR FINISH & PLUMBING & MS WORK AS PER PLAN. NO CHANGE IN USE, EGRESS & OCCUPANCY.
M01193788-I1
05/09/2025
Filed — Alteration
installation of heavy duty sidewalk shed and pipe scaffolding. no change in use, occupancy or egress. work shall comply with chapter 33 of nycbc.
M01218303-I1
05/09/2025
Permit issued — Sidewalk Shed
M01218303-I1-SH
05/09/2025
Permit issued — Sidewalk Shed
M01218303-I1-SF
03/13/2025
Special inspection requirement — Fenestration and door U-factor and product ratings
Thomas Vail
03/13/2025
Special inspection requirement — Lighting in dwelling units
Thomas Vail
03/12/2025
Special inspection requirement — Mechanical Systems
Thomas Vail
03/12/2025
Special inspection requirement — Final
Thomas Vail
07/27/2022
Filed — Alteration
M00780411-I1
07/27/2022
Permit issued — Supported Scaffold
M00780411-I1-SF
04/18/2022
Permit issued — General Construction
M00646725-I1-GC
04/11/2022
Filed — Alteration
Reconstruction of existing parapet wall & finish work on roof as per plan. No change in use, egress, or occupancy.
M00646725-I1
12/23/2021
Special inspection requirement — Final
TING I KANG
12/13/2021
Special inspection requirement — Fire-Resistant Penetrations and Joints
Xiong Wei Wu
12/13/2021
Special inspection requirement — Fire-Resistance Rated Construction
TING I KANG
12/13/2021
Special inspection requirement — Masonry
Xiong Wei Wu
10/01/2015
Violation issued (HPD, closed)
I
01/19/2007
Violation issued (DOB, closed)
V*-DOB VIOLATION - DISMISSED
01/31/2005
Violation issued (DOB, closed)
V*-DOB VIOLATION - DISMISSED
02/13/2004
Violation issued (DOB, closed)
V*-DOB VIOLATION - DISMISSED
Permit / Filing Register
SourceWork TypeStatusApplicantIssued
DOB NOWGeneral ConstructionSigned-offAIRPROS, INC11/12/2025
DOB NOWPlumbingSigned-offZ.W. PLBG & HTG CORP10/06/2025
DOB NOWGeneral ConstructionSigned-offDWG SERVICES INC08/08/2025
DOB NOWMechanical SystemsSigned-offHIICOMPANY CORP08/05/2025
DOB NOWSidewalk ShedSigned-offJ & G CONSTRUCTION SVCS05/09/2025
DOB NOWSidewalk ShedSigned-offJ & G CONSTRUCTION SVCS05/09/2025
DOB NOWSupported ScaffoldPermit IssuedZKW ENTERPRISES INC07/27/2022
DOB NOWGeneral ConstructionPermit IssuedLUBAN INC04/18/2022
BISOTISSUEDLUBAN INC09/30/2016
BIS—ISSUEDLUBAN INC11/12/2014
BISPLISSUEDJADA PLUMBING & HTG LLC09/10/2014
BISOTISSUEDLUBAN INC07/16/2014
BISPLISSUEDZ.W. PLBG & HTG CORP05/18/2004
BISOTISSUEDLUBAN INC05/10/2004
BISOTISSUEDLUBAN INC07/15/2003
BISPLISSUEDZ.W. PLBG & HTG CORP08/28/2002
BISBLISSUEDBIG APPLE PLBG CORP09/03/1993
BISPLISSUEDBIG APPLE PLBG CORP09/25/1992
BISBLISSUEDBIG APPLE PLBG CORP09/25/1992
2 projects · most recent 05/01/2026
Air Conditioning Systems
FiledStatusContractorScopeMake / Model / Capacity
05/01/2026Signed-offAIRPROS, INCAir Conditioning Systems
Cooling
Mitsubishi Electric Mitsubishi SVZ-KP36NA 910 CFM · Fan Coil Indoor ×1
Mitsubushi Outdoor Compressor SUZ-KA36NAHZ 36,000 BTU · Condensing Unit ×1
10/06/2025——Air Conditioning Systems
Cooling
Mitsubishi Electric MSZ-GS18NA 12,000 BTU · Split System ×4
MITSIBISHI MXZ4C36NA4U1 36,000 BTU · Heat Pump Outdoor ×1
1 project · most recent 05/01/2026
Gas Water/Sanitary
FiledStatusContractorScope
05/01/2026Signed-offZ.W. PLBG & HTG CORPGas, Water/Sanitary
3 projects · most recent 08/12/2025
General Wiring
FiledStatusContractorScope
08/12/2025CompleteAPOLLO ELECTRIC USA, INC—
08/12/2025CompleteAPOLLO ELECTRIC USA, INCGeneral Wiring
05/09/2025Permit IssuedRICHARD NEU—
▾Field Inspections (DOB CAP) — 5
DateTypeResultReport
04/14/2026Certified Water and Sanitary-WS-Fixtures-FinishCertifiedView ↗
04/10/2026Pass-Final PL - Up to 3 Requested FloorsPassView ↗
03/11/2026Pass-Final PL - Up to 3 Requested FloorsPassView ↗
10/31/2025Certified Water and Sanitary-WS-Sanitary Piping-RoughingCertifiedView ↗
10/29/2025Certified Water and Sanitary-WS-Sanitary Piping-RoughingCertifiedView ↗
▾Special Inspection Requirements (DOB NOW) — 13
DateRequirementInspectorRole
05/26/2026Energy Code Compliance InspectionsThomas Vailprogress
03/13/2026Energy Code Compliance InspectionsThomas Vailprogress
10/04/2025Duct leakage testing, insulation and designThomas Vailenergy_progress
08/01/2025FinalThomas Vailprogress
08/01/2025Mechanical SystemsThomas Vailspecial
03/13/2025Fenestration and door U-factor and product ratingsThomas Vailenergy_progress
03/13/2025Lighting in dwelling unitsThomas Vailenergy_progress
03/12/2025Mechanical SystemsThomas Vailspecial
03/12/2025FinalThomas Vailprogress
12/23/2021FinalTING I KANGprogress
12/13/2021Fire-Resistant Penetrations and JointsXiong Wei Wuspecial
12/13/2021Fire-Resistance Rated ConstructionTING I KANGprogress
12/13/2021MasonryXiong Wei Wuspecial
▾Documents — 96 on file (BIS + DOB NOW)
▸Plans & Drawings8
▸DOB NOWPlans/Sketch8
09/02/2026M00646725-I1Request digital key ↗
09/02/2026M00780411-I1Request digital key ↗
08/23/2026M01218303-I1Request digital key ↗
Showing 3 of 8 on file for this type
▸Applications & Permits16
▸DOB NOWLPC Approval/Permit6
08/17/2026M01193788-P2Open ↗
08/13/2026M01193788-S1Open ↗
08/13/2026M01193788-I1Open ↗
Showing 3 of 6 on file for this type
▸BISPLAN / WORK APPROVAL APPLICATION5
07/03/2017121956188Open ↗
08/10/2016122830464Open ↗
07/13/2016122830464Open ↗
Showing 3 of 5 on file for this type
▸BISWORK PERMIT APPLICATION4
10/11/2016122830464Open ↗
11/14/2014121956188Open ↗
09/12/2014121956179Open ↗
Showing 3 of 4 on file for this type
▸BISCERTIFICATE OF OCCUPANCY: APPLICATION1
12/30/2014121956188Open ↗
▸Seals & Professional Certifications31
▸BISTECHNICAL REPORT: RESPONSIBILITY/CERTIFICATION9
03/28/2017122830464Open ↗
10/11/2016122830464Open ↗
07/13/2016122830464Open ↗
Showing 3 of 9 on file for this type
▸DOB NOWDPL-1: Design Professional Seal & Signature8
09/02/2026M00780411-I1Open ↗
08/21/2026M01265412-I1Open ↗
08/17/2026M01193788-I1Open ↗
Showing 3 of 8 on file for this type
▸DOB NOWProgress Inspector Seal & Signature8
09/29/2026M01193788-S1Open ↗
09/01/2026M00646725-I1Open ↗
09/01/2026M00646725-I1Open ↗
Showing 3 of 8 on file for this type
▸DOB NOWSpecial Inspector Seal & Signature4
09/01/2026M00646725-I1Open ↗
09/01/2026M00646725-I1Open ↗
09/01/2026M01265412-I1Open ↗
Showing 3 of 4 on file for this type
▸BISPROFESSIONAL CERTIFICATION STATEMENT1
07/23/2014121956179Open ↗
▸BISPROFESSIONAL CERTIFIED CHECKLIST1
07/23/2014121956179Open ↗
▸Trade Schedules & Equipment4
▸BISSELF-CERT PLUMBING NOTICE3
07/17/2015121956179Open ↗
01/23/2015121956179Open ↗
11/28/2014121956179Open ↗
▸BISSCHEDULE B - PLUMBING/SPRINKLER/STANDPIPE1
07/23/2014121956179Open ↗
▸Safety & Tenant Protection2
▸BISTenant Protection Plan and Notes1
07/13/2016122830464Open ↗
▸BISDS1-Demolition Submittal Certification Form1
10/15/2014121956188Open ↗
▸Environmental & Asbestos8
▸DOB NOWDEP ACP-5: Asbestos Assessment Report6
08/21/2026M01265412-I1Open ↗
08/17/2026M01193788-S1Open ↗
08/17/2026M01193788-I1Open ↗
Showing 3 of 6 on file for this type
▸BISASBESTOS: COMPLETION OR CLOSEOUT (ACP20/21/5)1
10/11/2016122830464Open ↗
▸BISASBESTOS: CERTIFICATION (DEP ACP5)1
07/23/2014121956179Open ↗
▸Energy Compliance9
▸BISTECHNICAL REPORT: ENERGY CODE PROGRESS INSPS7
03/28/2017122830464Open ↗
10/11/2016122830464Open ↗
07/13/2016122830464Open ↗
Showing 3 of 7 on file for this type
▸BISAS-BUILT ENERGY ANALYSIS2
03/28/2017122830464Open ↗
12/03/2015121956179Open ↗
▸Approvals, Objections & Sign-offs5
▸BISCERTIFICATE OF OCCUPANCY/LOC: REQUEST2
03/28/2017122830464Open ↗
12/03/2015121956179Open ↗
▸BISLANDMARKS APPROVAL2
10/09/2014121956188Open ↗
07/23/2014121956179Open ↗
▸BISSCHEDULE A - OCCUPANCY / USE1
09/08/2014121956188Open ↗
▸Cost, Insurance & Ownership7
▸BISCOST AFFIDAVIT6
03/28/2017122830464Open ↗
08/10/2016122830464Open ↗
07/13/2016122830464Open ↗
Showing 3 of 6 on file for this type
▸BISHIC LICENSE OR AFFIDAVIT1
10/11/2016122830464Open ↗
▸Filing & Intake Forms6
▸BISEFILING COVER SHEET3
07/13/2016122830464Open ↗
09/08/2014121956188Open ↗
07/23/2014121956179Open ↗
▸BISADDITIONAL INFORMATION3
09/23/2016122830464Open ↗
07/13/2016122830464Open ↗
10/06/2014121956179Open ↗