← Back
BuildNYC
Elevator cooperative
Sutton Manor
440 EAST 56TH STREET · BIN 1040464
💬 Discuss this project
1955Year Built
13Stories
D4Building Class
R10Zoning
90,000 sfGross Floor Area
82Units
LL97 CoveredRent Stabilized15 Active Violations 3 old, status unconfirmed ▸FISP: SAFE
Elevator cooperative · Owner of record: Sutton Manor Apartment · 13,665 sf lot · 6.59 FAR built · Flood zone X
Locations of Work
ArchitectureStructuralElectricalMechanicalPlumbingEquipmentGeneral
Names shown beside floors are taken automatically from the text of filed documents and may be incomplete or wrong.
Permit Issued — active, not yet Signed-off
Whole building & multi-floor projectsHalstead Management1 filing
RoofSutton Manor Apartments Inc1p · 1 filing · 9 docs
PenthouseUnit PH1, Unit PHE, Unit PHF1p · 4 filings · 20 docs
Floor 9Unit 9B, Unit 9C, Unit 9FUnder Construction2p · 2 filings · 16 docs
Floor 8
Floor 7
Floor 6Unit 6FGUnder Construction2p · 1 filing · 4 docs
Floor 5
Floor 4Unit 4B, Unit 4C, Unit 4G2p · 3 filings · 18 docs
Floor 3
Floor 2
Floor 1
Site & exteriorSutton Manor Apartments Inc3 filings · 13 docs
▾Owner History (Filing Record)
Companies and organizations named on filings. Individual owners are not shown.
OwnerFilingsMost Recent
Sutton Manor Apartment4703/22/2026
58th Street Capital1307/08/2026
▾Design Consultants (Architect / Engineer of Record)
FirmFilingsMost Recent
Hany Rizkalla Architect105/04/2026
Kit Middleton Architect202/12/2025
P&L Associates412/28/2023
Midtown Preservation202/08/2023
March Associates410/04/2022
Rand Engineering & Architecture103/09/2022
Associates102/10/2022
Pace Engineering301/11/2022
Leon Skvirsky PE105/26/2021
Nancy Holwell, Architect109/23/2020
John Gilmer Architect202/03/2020
▾Filing Representatives (Expediters)
RepresentativeFilingsMost Recent
Eurocelt Expediting603/21/2026
PM Architecture803/21/2026
Midtown Preservation Architecture403/21/2026
Sol Building Consulting Services803/21/2026
Kit Middleton Architect P403/21/2026
MK Associates403/21/2026
Building Brothers203/21/2026
Socotec203/21/2026
▾Contractors (License-Anchored)
FirmTradeRolesMost Recent
Brend RestorationScaffold1007/08/2026
Brend Restorationspecialty_contractor407/08/2026
Celatech ConstructionGeneral Contractor307/08/2026
Andaloro ConstructionGeneral Contractor203/21/2026
Hudson Plumbing & MCHPlumbing207/08/2026
Sami Construction & RemodGeneral Contractor207/08/2026
Capitol Awning Cospecialty_contractor107/08/2026
Magic RollerGeneral Contractor107/08/2026
Go Pro Plumbing and HeatingPlumbing107/08/2026
Just Plumbing & HeatingPlumbing107/08/2026
Pacific Plumbing & HeatingPlumbing107/08/2026
Argon ElectricalElectrical103/22/2026
T.N.T. Plumbing & HeatingPlumbing107/08/2026
Bruni ElectricElectrical103/22/2026
L.J.F. Electric CoElectrical103/21/2026
Marty Allen Electrical CoElectrical103/21/2026
A & R Electrical ContractingElectrical103/21/2026
Black Bull BuldersGeneral Contractor107/08/2026
▾Special Inspection Agencies
AgencyLicense #FilingsMost Recent
Ryan Special Engineering2018102/12/2025
Linea3155510/04/2022
Rand Engineering & Architects266203/09/2022
Ace Structural Engineering496109/23/2020
MK Architecture476202/03/2020
Building Lifecycle
All (194)Filed (22)Permit Issued (23)Signed Off (14)Facade (FISP) (12)Violation (60)Inspection (9)Objection (24)Special Inspection (30)
10/01/2026
Violation issued (ECB, open)
Construction
09/06/2026
Violation issued (HPD, open)
B
09/06/2026
Violation issued (HPD, open)
C
09/06/2026
Violation issued (HPD, open)
B
09/06/2026
Violation issued (HPD, open)
B
05/29/2026
Permit issued — General Construction
M01394078-I1-GC
05/04/2026
Filed — Alteration
NON LOAD BEARING PARTITION REMOVAL AND CREATE ROOM
M01394078-I1
04/28/2026
Special inspection requirement — Final
Hany Rizkalla
04/25/2026
Permit issued — Plumbing
M01166527-S1-PL
06/17/2025
Inspection — Certified Water and Sanitary-WS-Sanitary Piping-Roughing
Certified
View inspection ↗
05/01/2025
Permit issued — Plumbing
M01166527-S1-PL
03/17/2025
Permit issued — General Construction
M01166527-I1-GC
03/04/2025
Objection resolved — Addressed
03/04/2025
Objection resolved — Addressed
02/25/2025
Objection raised — Energy
02/25/2025
Objection raised — Scope
02/12/2025
Filed — Alteration
IT IS FILED FOR DEMOLITION AND CONSTRUCTION OF INTERIOR PARTITIONS AND RENOVATION OF KITCHEN AND BATHROOMS IN AN EXISTING APARTMENT #9F. PL APPLICATION IS FILED SEPARATELY. NO CHANGE IN USE, OCCUPANCY, OR EGRESS.
M01166527-I1
02/12/2025
Filed — Alteration
IT IS FILED FOR DEMOLITION AND CONSTRUCTION OF INTERIOR PARTITIONS AND RENOVATION OF KITCHEN AND BATHROOMS IN AN EXISTING APARTMENT #9F. PL APPLICATION IS FILED SEPARATELY. NO CHANGE IN USE, OCCUPANCY, OR EGRESS.
M01166527-S1
01/27/2025
Special inspection requirement — Lighting in dwelling units
William Ryan
01/13/2025
Special inspection requirement — Energy Code Compliance Inspections
William Ryan
01/13/2025
Special inspection requirement — Fire-Resistant Penetrations and Joints
William Ryan
01/13/2025
Special inspection requirement — Final
William Ryan
01/13/2025
Special inspection requirement — Structural Stability – Alterations of existing buildings
William Ryan
01/13/2025
Special inspection requirement — Masonry
William Ryan
05/08/2024
Signed off — Alteration
Removal of non load bearing partition walls, flooring and lighting at Apt 4G. Provide new non load bearing walls, finishes and lighting. No change to use, egress, or occupancy under this filing
M00844599-S1
04/24/2024
Signed off — Alteration
Removal of non load bearing partition walls, flooring and lighting at Apt 4G. Provide new non load bearing walls, finishes and lighting. No change to use, egress, or occupancy under this filing
M00844599-I1
04/12/2024
Inspection — Certified Gas-Gas-Piping-Roughing
Certified
View inspection ↗
04/02/2024
Inspection — Fail-Final PL - Up to 3 Requested Floors
Fail
View inspection ↗
02/22/2024
Violation issued (DOB, open)
V-DOB VIOLATION - ACTIVE
12/29/2023
Special inspection requirement — Energy Code Compliance Inspections
Naeem Anwar
12/29/2023
Special inspection requirement — Final
Naeem Anwar
12/29/2023
Special inspection requirement — Fenestration and door U-factor and product ratings
Naeem Anwar
12/29/2023
Special inspection requirement — Fenestration air leakage
Naeem Anwar
12/29/2023
Special inspection requirement — Lighting in dwelling units
Naeem Anwar
12/29/2023
Special inspection requirement — Interior lighting power
Naeem Anwar
12/28/2023
Filed — Alteration
Removal of non load bearing partition walls, flooring and lighting at Apt 4G. Provide new non load bearing walls, finishes and lighting. No change to use, egress, or occupancy under this filing
M00844599-P2
12/18/2023
Filed — Alteration
Removal of non load bearing partition walls, flooring and lighting at Apt 4G. Provide new non load bearing walls, finishes and lighting. No change to use, egress, or occupancy under this filing
M00844599-P1
12/06/2023
Inspection — Fail-Final PL - Up to 3 Requested Floors
Fail
View inspection ↗
11/28/2023
Signed off — Alteration
FACADE REPAIRS & MISCELLANEOUS MAINTENANCE WORK, NO CHANGE IN USE, EGRESS OR OCCUPANCY.
M00494748-I1
11/02/2023
Violation issued (DOB, open)
V-DOB VIOLATION - ACTIVE
09/22/2023
Inspection — Fail-Final PL - Up to 3 Requested Floors
Fail
View inspection ↗
09/07/2023
Inspection — Certified Water and Sanitary-WS-Sanitary Piping-Roughing
Certified
View inspection ↗
08/02/2023
Violation issued (DOB, open)
V-DOB VIOLATION - ACTIVE
07/20/2023
Permit issued — Plumbing
M00844599-S1-PL
07/11/2023
Filed — Alteration
Removal of non load bearing partition walls, flooring and lighting at Apt 4G. Provide new non load bearing walls, finishes and lighting. No change to use, egress, or occupancy under this filing
M00844599-S1
06/14/2023
Signed off — Alteration
Penthouse renovation as per plans filed herewith. No change of use, egress, or occupancy.
M00640899-I1
05/09/2023
Permit issued — General Construction
M00844599-I1-GC
05/02/2023
Signed off — Alteration
Penthouse renovation as per plans filed herewith. No change of use, egress, or occupancy.
M00640899-S1
05/02/2023
Violation issued (DOB, open)
V-DOB VIOLATION - ACTIVE
05/01/2023
Signed off — Alteration
M00653116-I1
05/01/2023
Signed off — Alteration
Replacement of kitchen sink and dishwasher. Replacement of toilets, LAVS. Conversion of bathtubs to showers. As per plans filed herewith. No change of use, egress or occupancy.
M00640907-I1
04/28/2023
Filed — Alteration
Removal of non load bearing partition walls, flooring and lighting at Apt 4G. Provide new non load bearing walls, finishes and lighting. No change to use, egress, or occupancy under this filing
M00844599-I1
04/25/2023
Signed off — Alteration
Mechanical application in conjunction with alteration application #M00640899. As per plans filed herewith. No change of use, egress, or occupancy.
M00640910-I1
04/11/2023
Signed off — Alteration
M00542016-I1
02/17/2023
Objection resolved — Addressed
02/14/2023
Objection raised — Scope
02/09/2023
Cycle 9 facade report submitted
02/08/2023
Filed — Alteration
FACADE REPAIRS & MISCELLANEOUS MAINTENANCE WORK, NO CHANGE IN USE, EGRESS OR OCCUPANCY.
M00494748-P1
01/30/2023
Signed off — Alteration
INSTALLATION OF A TEMPORARY SCAFFOLD AS PER PLANS DURING GENERAL CONSTRUCTION. NO CHANGE IN USE, EGRESS OR OCCUPANCY. SCAFFOLD TO COMPLY WITH 2014 NYC BUILDING CODE, CHAPTER 33.
M00593657-I1
01/30/2023
Cycle 9 facade report signed — SAFE
Latest 60 of 194 events.
Permit / Filing Register
SourceWork TypeStatusApplicantIssued
DOB NOWGeneral ConstructionPermit IssuedMagic Roller05/29/2026
DOB NOWPlumbingPermit IssuedHudson Plumbing & MCH04/25/2026
DOB NOWPlumbingPermit IssuedHudson Plumbing & MCH05/01/2025
DOB NOWGeneral ConstructionPermit IssuedAndaloro Construction03/17/2025
DOB NOWPlumbingSigned-offMohamed Abdelrazek07/20/2023
DOB NOWGeneral ConstructionSigned-offBlack Bull Bulders05/09/2023
DOB NOWSupported ScaffoldSigned-offBrend Restoration09/21/2022
DOB NOWGeneral ConstructionSigned-offBrend Restoration08/09/2022
DOB NOWStructuralSigned-offBrend Restoration06/23/2022
DOB NOWSidewalk ShedSigned-offBrend Restoration06/10/2022
DOB NOWMechanical SystemsSigned-offSami Construction & Remod05/11/2022
DOB NOWGeneral ConstructionSigned-offBrend Restoration04/27/2022
DOB NOWPlumbingSigned-offPacific Plumbing & Heating04/15/2022
DOB NOWGeneral ConstructionSigned-offSami Construction & Remod03/08/2022
DOB NOWSupported ScaffoldSigned-offBrend Restoration09/29/2021
DOB NOWGeneral ConstructionSigned-offBrend Restoration08/12/2021
DOB NOWSidewalk ShedSigned-offBrend Restoration06/18/2021
DOB NOWGeneral ConstructionSigned-offCapitol Awning Co06/15/2021
DOB NOWPlumbingSigned-offGo Pro Plumbing and Heating04/06/2021
DOB NOWMechanical SystemsSigned-offCelatech Construction05/29/2020
DOB NOWMechanical SystemsSigned-offCelatech Construction05/29/2020
DOB NOWPlumbingSigned-offT.N.T. Plumbing & Heating02/27/2020
DOB NOWMechanical SystemsSigned-offCelatech Construction02/24/2020
BIS—ISSUEDHaistead Management Company10/27/2022
BISOTISSUEDMillenium Cent Contracting08/06/2021
BISOTISSUEDMillenium Cent Contracting03/11/2021
BISOTISSUEDCelatech Construction05/28/2020
BISOTISSUEDCelatech Construction04/13/2020
BISOTISSUEDCelatech Construction02/20/2020
BISPLISSUEDAura Plumbing10/11/2019
BISOTISSUEDKayafas Contracting Co06/13/2019
BISOTISSUEDRebosio Construction Service10/11/2018
BISPLISSUEDL&J PLG & Heating Co of NY04/27/2018
BISPLISSUEDPeter Miceli Plumbing12/14/2017
BISOTISSUEDGusto Interiors12/05/2017
BISPLISSUEDAlan E. Rosenberg06/21/2017
BISOTISSUEDGusto Interiors06/15/2017
BISPLISSUEDL&J PLG & Heating Co of NY03/30/2017
BISPLISSUEDJeffrey Vulpis Plumbing03/23/2017
BISOTISSUEDNichibi Organization12/30/2016
+ 33 more permits on file
1 project · most recent 02/12/2025
Gas Water/Sanitary
FiledStatusContractorScope
02/12/2025Permit IssuedGolds PlumbingGas, Water/Sanitary
21 projects · most recent 09/03/2026
General Wiring
FiledStatusContractorScope
09/03/2026Permit Issued2AK Light ElectricGeneral Wiring
05/06/2026Complete2AK Light ElectricGeneral Wiring
10/01/2025CompleteSupreme Electric—
01/29/2025CompleteAmsterdam ElectricGeneral Wiring
07/31/2024CompleteBruni ElectricGeneral Wiring
02/27/2024CompleteAE Electric—
05/02/2023CompleteAE Electric—
04/25/2023CompleteAE Electric—
04/14/2023CompleteApollo Electric—
02/09/2023CompleteA&E Electrical Systems CoGeneral Wiring
01/19/2023CompleteCentury ElectricGeneral Wiring
06/23/2021CompleteTop Shelf Electric—
02/12/2021CompleteBruni ElectricGeneral Wiring
12/18/2020CompleteA & R Electrical ContractingGeneral Wiring
11/24/2020CompleteArgon ElectricalGeneral Wiring
▾Field Inspections (DOB CAP) — 9
DateTypeResultReport
06/17/2025Certified Water and Sanitary-WS-Sanitary Piping-RoughingCertifiedView ↗
04/12/2024Certified Gas-Gas-Piping-RoughingCertifiedView ↗
04/02/2024Fail-Final PL - Up to 3 Requested FloorsFailView ↗
12/06/2023Fail-Final PL - Up to 3 Requested FloorsFailView ↗
09/22/2023Fail-Final PL - Up to 3 Requested FloorsFailView ↗
09/07/2023Certified Water and Sanitary-WS-Sanitary Piping-RoughingCertifiedView ↗
01/17/2023Certified Remove/Cap - work done in accordance with codeCertifiedView ↗
01/17/2023Certified Water and Sanitary-WS-Fixtures-FinishCertifiedView ↗
06/23/2022Certified Water and Sanitary-WS-Sanitary Piping-RoughingCertifiedView ↗
▾Special Inspection Requirements (DOB NOW) — 34
DateRequirementInspectorRole
04/28/2026FinalHany Rizkallaprogress
01/27/2025Lighting in dwelling unitsWilliam Ryanenergy_progress
01/13/2025Energy Code Compliance InspectionsWilliam Ryanprogress
01/13/2025Fire-Resistant Penetrations and JointsWilliam Ryanspecial
01/13/2025FinalWilliam Ryanprogress
01/13/2025Structural Stability – Alterations of existing buildingsWilliam Ryanspecial
01/13/2025MasonryWilliam Ryanspecial
12/29/2023Energy Code Compliance InspectionsNaeem Anwarprogress
12/29/2023FinalNaeem Anwarprogress
12/29/2023Fenestration and door U-factor and product ratingsNaeem Anwarenergy_progress
12/29/2023Fenestration air leakageNaeem Anwarenergy_progress
12/29/2023Lighting in dwelling unitsNaeem Anwarenergy_progress
12/29/2023Interior lighting powerNaeem Anwarenergy_progress
01/16/2023Insulation placement and R valuesMichael Sleimanenergy_progress
01/16/2023FinalMichael Sleimanprogress
10/04/2022Fire-Resistant Penetrations and JointsLisa Vangelasspecial
09/07/2022Fire-Resistant Penetrations and JointsLisa Vangelasspecial
03/04/2022MasonryJames Vignolaspecial
03/04/2022Structural Steel - DetailsJames Vignolaspecial
03/04/2022FinalJames Vignolaprogress
03/04/2022Structural Steel - High Strength BoltingJames Vignolaspecial
03/04/2022Post-installed AnchorsJames Vignolaspecial
03/04/2022Structural Stability – Alterations of existing buildingsJames Vignolaspecial
03/04/2022Structural Steel - WeldingJames Vignolaspecial
12/23/2021Fenestration and door U-factor and product ratingsLisa Vangelasenergy_progress
Latest 25 of 34.
▾Documents — 516 on file (BIS + DOB NOW)
▸Plans & Drawings22
▸DOB NOWPlans/Sketch19
09/03/2026M00494748-I1Request digital key ↗
09/03/2026M00505450-I1Request digital key ↗
09/03/2026M00542016-I1Request digital key ↗
Showing 3 of 19 on file for this type
▸DOB NOWPlans/Sketch - Plumbing2
09/05/2026M00301097-I1Request digital key ↗
09/04/2026M00392524-I1Request digital key ↗
▸DOB NOWPlans/Sketch - Mechanical Systems1
09/05/2026M00301465-I1Request digital key ↗
▸Applications & Permits84
▸BISWORK PERMIT APPLICATION44
10/27/2022123916245Open ↗
03/11/2021140954037Open ↗
02/24/2021140954037Open ↗
Showing 3 of 44 on file for this type
▸BISPLAN / WORK APPROVAL APPLICATION37
08/26/2022123916245Open ↗
09/22/2020140954037Open ↗
01/28/2020123694537Open ↗
Showing 3 of 37 on file for this type
▸BISCERTIFICATE OF OCCUPANCY: APPLICATION1
09/20/2023123916245Open ↗
▸BISPARTIAL DEMO PLAN & DS1 (FOR AL/EW-OT PERMITS)1
03/02/2021140954037Open ↗
▸BISPARTIAL DEMO: 10-DAY NOTICE (FOR AL/EW-OT PERMITS)1
02/18/2021140954037Open ↗
▸Zoning, Tax Lot & Property Records1
▸BISVERIFY TAX LOT1
09/19/2023123916245Open ↗
▸Seals & Professional Certifications126
▸BISTECHNICAL REPORT: RESPONSIBILITY/CERTIFICATION51
01/28/2020123694537Open ↗
01/28/2020123694537Open ↗
12/17/2019123695117Open ↗
Showing 3 of 51 on file for this type
▸DOB NOWDPL-1: Design Professional Seal & Signature22
09/05/2026M00301465-I1Open ↗
09/04/2026M00392524-I1Open ↗
09/03/2026M00494748-I1Open ↗
Showing 3 of 22 on file for this type
▸DOB NOWProgress Inspector Seal & Signature17
09/26/2026M00844599-I1Open ↗
09/26/2026M00844599-I1Open ↗
09/26/2026M00844599-I1Open ↗
Showing 3 of 17 on file for this type
▸DOB NOWSpecial Inspector Seal & Signature10
08/31/2026M00640899-S1Open ↗
08/31/2026M00640899-S1Open ↗
08/31/2026M00640899-S1Open ↗
Showing 3 of 10 on file for this type
▸BISPROFESSIONAL CERTIFIED CHECKLIST9
10/05/2022123916245Open ↗
Showing 1 of 9 on file for this type
▸BISPROFESSIONAL CERTIFICATION STATEMENT7
On file, but not among the 200 most recently loaded documents for this source.
Showing 0 of 7 on file for this type
▸BISREQUIRED ITEMS CHECKLIST FOR PROFESSIONAL CERTIFICATION3
On file, but not among the 200 most recently loaded documents for this source.
Showing 0 of 3 on file for this type
▸BISTECHNICAL REPORT STATEMENT OF RESPONSIBILITY3
On file, but not among the 200 most recently loaded documents for this source.
Showing 0 of 3 on file for this type
▸BISAPPLICANT OWNER SIGNATURE2
09/22/2020140954037Open ↗
Showing 1 of 2 on file for this type
▸BISPROFESSIONAL CERTIFICATION STATEMENT FORM2
On file, but not among the 200 most recently loaded documents for this source.
Showing 0 of 2 on file for this type
▸Trade Schedules & Equipment17
▸BISSCHEDULE B - PLUMBING/SPRINKLER/STANDPIPE8
10/01/2019123808576Open ↗
05/01/2019123808576Open ↗
10/09/2018123516702Open ↗
Showing 3 of 8 on file for this type
▸BISSELF-CERT PLUMBING NOTICE4
On file, but not among the 200 most recently loaded documents for this source.
Showing 0 of 4 on file for this type
▸BISSCHEDULE B - PLUMBING4
03/21/2016140324806Open ↗
Showing 1 of 4 on file for this type
▸BISDETECTOR:SMOKE-CERT. OF INSTALLATION1
10/11/2017123028142Open ↗
▸Safety & Tenant Protection15
▸BISTenant Protection Plan and Notes8
01/28/2020123694537Open ↗
10/25/2019123695117Open ↗
05/01/2019123808576Open ↗
Showing 3 of 8 on file for this type
▸DOB NOWTenant Protection Plan3
08/13/2026M00301097-I1Open ↗
08/13/2026M00301465-I1Open ↗
08/13/2026M00392524-I1Open ↗
▸BISSTREET TREES: RECEIPT OF STREET TREES SITE PLAN1
10/27/2022123916245Open ↗
▸BISTPP1: TENANT PROTECTION PLAN1
10/27/2022123916245Open ↗
▸BISSTREET TREE CHECKLIST1
10/05/2022123916245Open ↗
▸BISSTREET TREE SIGNOFF1
09/19/2023123916245Open ↗
▸Environmental & Asbestos38
▸DOB NOWDEP ACP-5: Asbestos Assessment Report18
09/05/2026M00301465-I1Open ↗
09/04/2026M00392524-I1Open ↗
09/03/2026M00494748-I1Open ↗
Showing 3 of 18 on file for this type
▸BISASBESTOS: CERTIFICATION (DEP ACP5)16
09/22/2020140954037Open ↗
02/12/2020123694537Open ↗
10/25/2019123695117Open ↗
Showing 3 of 16 on file for this type
▸BISTHIS IS 'NOT AN ASBESTOS PROJECT'2
On file, but not among the 200 most recently loaded documents for this source.
Showing 0 of 2 on file for this type
▸BISASBESTOS EXEMPTION CERTIFICATION LETTER1
On file, but not among the 200 most recently loaded documents for this source.
Showing 0 of 1 on file for this type
▸BISASBESTOS: COMPLETION OR CLOSEOUT (ACP 20-21-5)1
On file, but not among the 200 most recently loaded documents for this source.
Showing 0 of 1 on file for this type
▸Energy Compliance69
▸BISTECHNICAL REPORT: ENERGY CODE PROGRESS INSPS33
01/28/2020123694537Open ↗
12/17/2019123695117Open ↗
11/13/2019123695117Open ↗
Showing 3 of 33 on file for this type
▸BISAS-BUILT ENERGY ANALYSIS17
11/23/2020123694537Open ↗
11/21/2019123808576Open ↗
03/05/2019123516702Open ↗
Showing 3 of 17 on file for this type
▸BISTECHNICAL REPORT: ENERGY CODE - RESPONSIBILITY7
10/05/2022123916245Open ↗
01/20/2022140954037Open ↗
01/20/2022140954037Open ↗
Showing 3 of 7 on file for this type
▸DOB NOWEN2: As Built Energy Analysis4
09/02/2026M00653116-I1Open ↗
08/13/2026M00640899-I1Open ↗
08/13/2026M00640910-I1Open ↗
Showing 3 of 4 on file for this type
▸BISTR8: Energy Code Progress Inspections3
On file, but not among the 200 most recently loaded documents for this source.
Showing 0 of 3 on file for this type
▸BISAS-BUILT ENERGY ANALYSIS (EN2)2
01/20/2022140954037Open ↗
05/06/2021123695117Open ↗
▸BISELECTRICAL APPLICATION FOR SIDEWALK SHED LIGHTING2
On file, but not among the 200 most recently loaded documents for this source.
Showing 0 of 2 on file for this type
▸BISENERGY CODE COMPLIANCE INSPECTIONS1
04/30/2021123695117Open ↗
▸Inspections & Test Reports18
▸BISTECHNICAL REPORT: RESPONSIBILITY16
10/05/2022123916245Open ↗
01/20/2022140954037Open ↗
01/20/2022140954037Open ↗
Showing 3 of 16 on file for this type
▸BISFIRE-RESISTANT PENETRATIONS AND JOINTS (FIRESTOP)1
05/06/2021123695117Open ↗
▸BISTECHNICAL REPORT: PILE DRIVING1
02/09/2018122869422Open ↗
▸Approvals, Objections & Sign-offs37
▸BISCERTIFICATE OF OCCUPANCY/LOC: REQUEST24
01/21/2022140954037Open ↗
05/06/2021123695117Open ↗
11/23/2020123694537Open ↗
Showing 3 of 24 on file for this type
▸BISLETTERS - SUPPORTING DOCUMENTATION6
10/11/2017123028142Open ↗
12/14/2016121769489Open ↗
Showing 2 of 6 on file for this type
▸BISADMINISTRATIVE OBJECTIONS4
On file, but not among the 200 most recently loaded documents for this source.
Showing 0 of 4 on file for this type
▸BISSCHEDULE A - OCCUPANCY / USE1
10/05/2022123916245Open ↗
▸BISFINAL1
05/06/2021123695117Open ↗
▸BISCCD1-Construction Code Determination1
On file, but not among the 200 most recently loaded documents for this source.
Showing 0 of 1 on file for this type
▸Cost, Insurance & Ownership41
▸BISCOST AFFIDAVIT39
10/05/2022123916245Open ↗
11/23/2020123694537Open ↗
09/23/2020140954037Open ↗
Showing 3 of 39 on file for this type
▸BISCOST AFFIDAVIT (FINAL): PW32
01/20/2022140954037Open ↗
04/30/2021123695117Open ↗
▸Filing & Intake Forms45
▸BISEFILING COVER SHEET17
08/26/2022123916245Open ↗
01/28/2020123694537Open ↗
10/25/2019123695117Open ↗
Showing 3 of 17 on file for this type
▸BISADDITIONAL INFORMATION15
12/15/2020140954037Open ↗
09/06/2018122991744Open ↗
02/06/2018122627407Open ↗
Showing 3 of 15 on file for this type
▸BISBOROUGH INTAKE FORM7
11/21/2019123808576Open ↗
10/01/2019123808576Open ↗
03/05/2019123516702Open ↗
Showing 3 of 7 on file for this type
▸BISEFILING JOB APPLICATION COVER SHEET6
09/22/2020140954037Open ↗
Showing 1 of 6 on file for this type
▸Other Documents3
▸BISTENANT/OCCUPANT PROTECTION PLAN 2008 CODE1
On file, but not among the 200 most recently loaded documents for this source.
Showing 0 of 1 on file for this type
▸BISUnknown1
12/19/2019123695117Open ↗
▸BISDepartment of Consumer Affairs (DCA) Form1
On file, but not among the 200 most recently loaded documents for this source.
Showing 0 of 1 on file for this type