← Back
Two family brick
4408 WICKHAM AVENUE
BRONX · BIN 2071197
💬 Discuss this project
1950Year Built
2Stories
B1Building Class
R4-1Zoning
2,750 sfGross Floor Area
2Units
Two family brick · 2,338 sf lot · 1.18 FAR built · Flood zone X
Locations of Work
Electrical
Roof1 filing · 8 docs
▾Design Consultants (Architect / Engineer of Record)
FirmFilingsMost Recent
MOMENTUM SOLAR112/19/2023
▾Special Inspection Agencies
AgencyLicense #FilingsMost Recent
SHAHRISH SHUVO ENGINEERIN8524112/19/2023
Building Lifecycle
All (11)Filed (1)Permit Issued (1)Objection (4)Special Inspection (5)
01/25/2024
Permit issued — Solar
X00978246-I1-SL
01/10/2024
Objection resolved — Addressed
01/10/2024
Objection resolved — Addressed
01/08/2024
Objection raised — Other
01/08/2024
Objection raised — Other
12/19/2023
Filed — Alteration
Installation of solar panels, rooftop, grid tied, RAILED (3.6 KW)(9 MODULES)
X00978246-I1
12/15/2023
Special inspection requirement — Fire-Resistant Penetrations and Joints
Shahrish Shuvo
12/15/2023
Special inspection requirement — Structural Stability – Alterations of existing buildings
Shahrish Shuvo
12/15/2023
Special inspection requirement — Energy Code Compliance Inspections
Mina Makar
12/15/2023
Special inspection requirement — Final
Mina Makar
12/15/2023
Special inspection requirement — Air barrier - visual inspection
Mina Makar
Permit / Filing Register
SourceWork TypeStatusApplicantIssued
DOB NOWSolarPermit IssuedMOMENTUM SOLAR01/25/2024
1 project · most recent 12/15/2023
FiledStatusContractorScope
12/15/2023CompleteISLAND ELECTRIC CORP—
1 project · most recent 12/19/2023
FiledStatusContractorScope
12/19/2023Permit IssuedMOMENTUM SOLAR9 panels, 3.6 kw, 158 roof_area_sqft
▾Special Inspection Requirements (DOB NOW) — 5
DateRequirementInspectorRole
12/15/2023Fire-Resistant Penetrations and JointsShahrish Shuvospecial
12/15/2023Structural Stability – Alterations of existing buildingsShahrish Shuvospecial
12/15/2023Energy Code Compliance InspectionsMina Makarprogress
12/15/2023FinalMina Makarprogress
12/15/2023Air barrier - visual inspectionMina Makarenergy_progress
▾Documents — 7 on file (BIS + DOB NOW)
▸Plans & Drawings1
▸DOB NOWPlans/Sketch1
08/21/2026X00978246-I1Request digital key ↗
▸Seals & Professional Certifications4
▸DOB NOWProgress Inspector Seal & Signature2
08/29/2026X00978246-I1Open ↗
08/29/2026X00978246-I1Open ↗
▸DOB NOWDPL-1: Design Professional Seal & Signature1
08/21/2026X00978246-I1Open ↗
▸DOB NOWSpecial Inspector Seal & Signature1
08/29/2026X00978246-I1Open ↗
▸Environmental & Asbestos1
▸DOB NOWDEP ACP-5: Asbestos Assessment Report1
08/21/2026X00978246-I1Open ↗
▸Approvals, Objections & Sign-offs1
▸DOB NOWUtility Company Final Acceptance Letter1
08/13/2026X00978246-I1Open ↗