ECB09/12/2025UNABLE TO GAIN ACCESS TO 441 EAST 6TH STREET. HOWEVER, THERE IS NO CERTIFICATE OF CORRECTION ON FILE FOR CLASS 1 VIOLATION #3909033Y ISSUED ON 7/17/2023 FOR STAIRCASES AT 1ST FLOOR TO ROOF WITH RUST AND CORROSI$6K due
HPD04/12/2023§ 27-2021 ADM CODE PROVIDE PLACE WITHIN THE BUILDING FOR THE STORAGE OF WASTE RECEPTACLES AND DISINFECT SAME REGULARLY.
HPD02/12/2019§ 27-2005, 2007 ADM CODE ARRANGE AND MAKE SELF-CLOSING THE DOORS ..... IN THE ENTRANCE LOCATED AT APT 3F, 3rd STORY, 1st APARTMENT FROM EAST AT SOUTH
HPD02/12/2019§ 27-2005 ADM CODE PROPERLY REPAIR THE BROKEN OR DEFECTIVE COUNTERBALANCE AT LOWER WINDOW SASH IN THE KITCHEN LOCATED AT APT 3F, 3rd STORY, 1st APARTMENT FROM EAST AT SOUTH
HPD02/12/2019§ 27-2005 ADM CODE PAINT METAL IN ACCORDANCE WITH DEPT. REGULATION ...METAL CEILING IN THE KITCHEN LOCATED AT APT 3F, 3rd STORY, 1st APARTMENT FROM EAST AT SOUTH
HPD02/12/2019§ 27-2046.1 HMC: REPAIR OR REPLACE THE CARBON MONOXIDE DETECTING DEVICE(S). ...DEFECTIVE IN THE ENTIRE APARTMENT LOCATED AT APT 3F, 3rd STORY, 1st APARTMENT FROM EAST AT SOUTH
HPD02/12/2019§ 27-2045 ADM CODE REPAIR OR REPLACE THE SMOKE DETECTOR ...DEFECTIVE IN THE ENTIRE APARTMENT LOCATED AT APT 3F, 3rd STORY, 1st APARTMENT FROM EAST AT SOUTH
HPD02/02/2018§ 27-2013 ADM CODE PAINT WITH LIGHT COLORED PAINT TO THE SATISFACTION OF THIS DEPARTMENT AT CEILING AT PUBLIC HALL, 5th STORY
HPD02/02/2018§ 27-2053 ADM CODE POST SIGN ON WALL OF ENTRANCE STORY BEARING NAME, ADDRESS INCLUDING APARTMENT NUMBER IF ANY, AND TELEPHONE NUMBER OF SUPERINTENDENT, JANITOR OR HOUSEKEEPER. AT PUBLIC HALL, 1st STORY
HPD02/02/2018§ 27-2046.1 HMC: POST A PROPER NOTICE OF CARBON MONOXIDE DETECTING DEVICE REQUIREMENTS, IN A FORM APPROVED BY THE COMMISSIONER, IN A COMMON AREA OF A CLASS A MULTIPLE DWELLING NEAR INSPECTION CERTIFICATE OR PROVIDE NOTICE TO TENANTS IN A PRIVATE DWELLING. AT PUBLIC HALL, 1st STORY
HPD02/02/2018§ 27-2033 ADM CODE POST NOTICE, IN FORM APPROVED BY THE DEPARTMENT, STATING THE NAME AND LOCATION OF THE PERSON DESIGNATED BY THE OWNER TO HAVE KEY TO BUILDINGS HEATING SYSTEM SIGN MISSING AT PUBLIC HALL, 1st STORY
HPD10/25/2017§ 26-1103 ADMIN. CODE: POST AND MAINTAIN A PROPER NOTICE ON WALL OF THE ENTRANCE STORY IN ENGLISH AND SPANISH ON THE AVAILABILITY OF THE AGENCYS HOUSING INFORMATION GUIDE. A SAMPLE NOTICE CAN BE FOUND AT WWW.NYC.GOV/HPD. AT PUBLIC HALL, 1st STORY
HPD10/25/2017§ 27-2005 HMC: POST, IN A FORM APPROVED BY THE COMMISSIONER, AND MAINTAIN A NOTICE IN A COMMON AREA OF THE BUILDING REGARDING THE PROCEDURES THAT SHOULD BE FOLLOWED WHEN A GAS LEAK IS SUSPECTED AT PUBLIC HALL, 1st STORY
DOB12/05/2016FAIL TO COMPLY W/COMMISSIONER ORDER#334275 ISSUED ON 11/10/16 TO REINSTATE RELIEVING WALL AT APT 4F& EVALUATE RELIEVING WALL AT THE WHOLE BLDG&OBTAIN PERMITS NO LATER THAN 11/28/16.PERMITS HAVE NOT BEEN OBTAINED AS OF 12/5/16.REMEDY:COMPLY WITH COMMISSIONERS ORDER#334275 IMMED
DOB11/10/2016FAILURE TO KEEP BLDG IN SAFE COND.STAIR&STAIR HALL/LANDING FROM 2ND FL TO ROOF ARE EXCESSIVELY LEANING INWARD.STAIR BULKHEAD AT ROOF LEANING TOWARDS BLDG FOOTPRINT.REMEDY:OWNER ENGAGE NYS PE LIC ENGR&CONT'R TO EVALUATE BLDG,OBTAIN PERMIT FOR WORK NO LATER 12/16/16.REPAIR JOB BE SIGNED OFF NO LATER 3/1/17.LEGAL TEMP SHORING WORK/CELLAR NO LATER
DOB11/10/2016FAILURE TO KEEP BLDG IN SAFE COND.UPON INSPECT OF APT4F,WAS DISCOVERED THE RELIEVING WALL WAS REMOVED THERE BY CREATING AN UNSAFE COND OF NO ADEQUATE STRL SUPPORT/FIRE PROTECTION BET 4TH&5TH FLRS.REMEDY:IMMED VACATE APT4F.OWNER ENGAGE NYS PE LIC ENGR&CONT'R EVALUATE RELIEVING WALL AT WHOLE BLDG.PERMIT FOR WORK BE OBTAINED NO LATER THAN 11/28/16
HPD10/28/2016§ 27-2046.1 HMC: REPAIR OR REPLACE THE CARBON MONOXIDE DETECTING DEVICE(S). MISSING IN THE ENTIRE APARTMENT LOCATED AT APT 3F, 3rd STORY, 1st APARTMENT FROM EAST AT SOUTH
HPD10/28/2016§ 26-1103 ADMIN. CODE: POST AND MAINTAIN A PROPER NOTICE ON WALL OF THE ENTRANCE STORY IN ENGLISH AND SPANISH ON THE AVAILABILITY OF THE AGENCYS HOUSING INFORMATION GUIDE. A SAMPLE NOTICE CAN BE FOUND AT WWW.NYC.GOV/HPD. AT PUBLIC HALL, 1st STORY
ECB07/17/2023FAILURE TO MAINTAIN BUILDING IN A CODE-COMPLIANT MANNER. AT THE TIME OF INSPECTION, I OBSERVED STAIRCASES IN THE ENTIRE BUILDING ARE TWISTED FROM THE FIRST FLOOR TO THE ROOF. REAR METAL STAIRCASE TO REAR YARD INothing owed — awaiting certificate of correction