← Back
BuildNYC
Three families
443 QUINCY STREET
BROOKLYN · BIN 3414292
💬 Discuss this project
2007Year Built
3Stories
C0Building Class
R6BZoning
4,200 sfGross Floor Area
3Units
Three families · 2,670 sf lot · 1.57 FAR built · Flood zone X
Locations of Work
ArchitectureElectricalMechanicalPlumbingGeneral
Names shown beside floors are taken automatically from the text of filed documents and may be incomplete or wrong.
RoofBuilding mounted solar electric generation array installatio3p · 2 filings · 20 docs
Floor 311p · 1 filing · 20 docs
Floor 28p · 1 filing · 20 docs
Floor 19p · 1 filing · 20 docs
▾Design Consultants (Architect / Engineer of Record)
FirmFilingsMost Recent
Andrew Carlin R.A.608/07/2024
Momentum Solar105/28/2024
▾Contractors (License-Anchored)
FirmTradeRolesMost Recent
Denova Home ImprovementGeneral Contractor203/21/2026
Rock E Small Plumbing & HeatingPlumbing207/08/2026
901 Green Avenue BuildersGeneral Contractor103/21/2026
Carribean Sunset ConstructionGeneral Contractor103/21/2026
Construx FramingGeneral Contractor103/21/2026
Cape PlumbingPlumbing103/21/2026
First Choice PlumbingPlumbing103/21/2026
Omd ElectricalElectrical103/22/2026
EZ Runer ConstructionPlumbing106/14/2022
L&J PLG & Heating Co of NYPlumbing109/04/2018
Wagner Ziv Plumbing & HeatingPlumbing106/20/2007
Webb Development ServicesGeneral Contractor210/23/2019
▾Special Inspection Agencies
AgencyLicense #FilingsMost Recent
MXV Sia9281105/28/2024
G Engineering7778112/27/2023
Triangle Inspection & Tes7495112/27/2023
Building Lifecycle
04/17/2026
Objection raised — Zoning
04/07/2026
Special inspection requirement — Insulation placement and R values
04/07/2026
Special inspection requirement — Permanent certificate
04/07/2026
Special inspection requirement — Air barrier — testing
04/07/2026
Special inspection requirement — Air barrier - visual inspection
39 history events on file for this building. Sign in free to see the full history. Sign in · Create account
Permit / Filing Register
SourceWork TypeStatusApplicantIssued
DOB NOWPlumbingPermit IssuedRock E Small Plumbing & Heating11/01/2024
DOB NOWSolarPermit IssuedMomentum Solar05/30/2024
BISPLISSUEDRock E Small Plumbing & Heating01/18/2024
BISPLISSUEDRock E Small Plumbing & Heating12/22/2022
BISPLISSUEDEZ Runer Construction06/14/2022
BISPLISSUEDCape Plumbing01/24/2022
BISPLISSUEDCape Plumbing11/19/2020
BISEQISSUEDWebb Development Service10/23/2019
BIS—ISSUEDWebb Development Service10/23/2019
BIS—ISSUED901 Green Avenue Builders11/13/2018
BISPLISSUEDL&J PLG & Heating Co of NY09/04/2018
BIS—ISSUED901 Green Avenue Builders04/24/2018
BISPLISSUEDFirst Choice Plumbing04/26/2011
BIS—ISSUEDCarribean Sunset Construction06/22/2009
BISPLISSUEDFirst Choice Plumbing05/12/2009
BISEQISSUEDCarribean Sunset Construction04/28/2009
BISEQISSUEDConstrux Framing03/24/2009
BIS—ISSUEDDenova Home Improvement10/11/2007
BISPLISSUEDWagner Ziv Plumbing & Heating06/20/2007
BIS—ISSUEDDenova Home Improvement04/27/2007
BISEQISSUEDDenova Home Improvement04/27/2007
1 project · most recent 08/07/2024
Heating and Air Conditioning Systems
FiledStatusContractorScope
08/07/2024——Heating and Air Conditioning Systems
1 project · most recent 08/07/2024
Gas Plumbing-Sprinkler Storm Water/Sanitary
FiledStatusContractorScope
08/07/2024Permit IssuedRock E Small Plumbing & HeatingGas, Plumbing-Sprinkler, Storm, Water/Sanitary
3 projects · most recent 08/29/2024
General Wiring
FiledStatusContractorScope
08/29/2024CompleteIsland Electric—
05/28/2024Permit IssuedIsland Electric—
02/02/2022CompleteOmd ElectricalGeneral Wiring
▾Field Inspections (DOB CAP) — 3
DateTypeResultReport
11/15/2024Certified Storm Drainage-ST-Piping-RoughingCertifiedView ↗
11/15/2024Certified Storm Drainage-ST-Piping-UndergroundCertifiedView ↗
11/15/2024Certified Water and Sanitary-WS-Sanitary Piping-RoughingCertifiedView ↗
▾Special Inspection Requirements (DOB NOW) — 23
DateRequirementInspectorRole
04/07/2026Insulation placement and R values—energy_progress
04/07/2026Permanent certificate—energy_progress
04/07/2026Air barrier — testing —energy_progress
04/07/2026Air barrier - visual inspection—energy_progress
04/07/2026Fenestration and door U-factor and product ratings—energy_progress
04/07/2026Fenestration air leakage—energy_progress
04/07/2026Fenestration areas—energy_progress
08/08/2024Soil Percolation Test - Private On-Site Storm Water Drainage Disposal Systems, and Detention FacilitiesRajasekhar Sakhamurispecial
08/08/2024Sprinkler SystemsXIONGCAI GUspecial
08/08/2024Private On-Site Storm Water Disposal Systems-, and Detention Facilities, InstallationXIONGCAI GUspecial
08/08/2024Fire-Resistant Penetrations and JointsXIONGCAI GUspecial
08/06/2024Fire-Resistant Penetrations and Joints—special
08/06/2024Private On-Site Storm Water Disposal Systems-, and Detention Facilities, Installation—special
08/06/2024Soil Percolation Test - Private On-Site Storm Water Drainage Disposal Systems, and Detention Facilities—special
08/06/2024Sprinkler Systems—special
05/19/2024Mechanical Systems—special
05/19/2024Final—progress
05/14/2024Soil Percolation Test - Private On-Site Storm Water Drainage Disposal Systems, and Detention Facilities—special
05/14/2024Fire-Resistant Penetrations and Joints—special
05/14/2024Private On-Site Storm Water Disposal Systems-, and Detention Facilities, Installation—special
05/14/2024Sprinkler Systems—special
10/17/2023Energy Code Compliance Inspections—progress
10/08/2023Fire-Resistant Penetrations and Joints—special
49 filed documents on file for this building. Sign in free to see the full history. Sign in · Create account