4449 SETON AVENUE
BRONX · BIN 2095171
💬 Discuss this project
1965Year Built
3Stories
C0Building Class
R4AZoning
2,836 sfGross Floor Area
3Units
Three families · 5,570 sf lot · 0.51 FAR built · Flood zone X
Locations of Work
Plumbing
Floor 21p · 1 filing · 3 docs
Floor 1
▾Design Consultants (Architect / Engineer of Record)
FirmFilingsMost Recent
NMI ARCHITECTURE, PLLC201/08/2026
▾Filing Representatives (Expediters)
RepresentativeFilingsMost Recent
MIGLIORE RESTORATION403/21/2026
▾Contractors (License-Anchored)
FirmTradeRolesMost Recent
THEORY 3 GROUP INCGeneral Contractor104/09/2026
INFINITI ESC PLUMBING CORPlumbing107/08/2026
▾Special Inspection Agencies
AgencyLicense #FilingsMost Recent
NMI ARCHITECTURE, PLLC6825112/03/2025
Building Lifecycle
All (23)Filed (2)Permit Issued (2)Signed Off (2)Inspection (9)Objection (2)Special Inspection (6)
07/17/2026
Inspection — Pass-Final PL - Up to 9 Requested Floors
Pass
View inspection ↗
04/23/2026
Signed off — Alteration
X01323858-I1
04/21/2026
Signed off — Alteration
THIS APPLICATION IS FILED TO REPAIR THE EX TWO FAMILY RES AFTER FIRE AND SMOKE DAMAGE AND 2ND AND THIRD FLOORS, MINOR DAMAGE AT FIRST FLOOR, NO CHANGE OF USE, EGRESS OR OCCUPANCY
X01323788-I1
04/17/2026
Inspection — Pass-Final General Construction Non-Directive 14
Pass
View inspection ↗
04/14/2026
Inspection — Pass-Final PL - Up to 3 Requested Floors
Pass
View inspection ↗
04/07/2026
Inspection — Certified Water and Sanitary-WS-Fixtures-Finish
Certified
View inspection ↗
03/04/2026
Inspection — Certified Water and Sanitary-WS-Sanitary Piping-Roughing
Certified
View inspection ↗
03/04/2026
Inspection — Certified Water and Sanitary-WS-Sanitary Piping-Underground
Certified
View inspection ↗
02/27/2026
Inspection — Certified Water and Sanitary-WS-Sanitary Piping-Underground
Certified
View inspection ↗
02/26/2026
Inspection — Certified Remove/Cap - work done in accordance with code
Certified
View inspection ↗
02/12/2026
Inspection — Pass-Final PL - Up to 9 Requested Floors
Pass
View inspection ↗
02/02/2026
Permit issued — Plumbing
X01323858-I1-PL
01/29/2026
Permit issued — General Construction
X01323788-I1-GC
01/21/2026
Objection resolved — Addressed
01/08/2026
Filed — Alteration
X01323858-I1
12/10/2025
Objection raised — Scope
12/03/2025
Filed — Alteration
THIS APPLICATION IS FILED TO REPAIR THE EX TWO FAMILY RES AFTER FIRE AND SMOKE DAMAGE AND 2ND AND THIRD FLOORS, MINOR DAMAGE AT FIRST FLOOR, NO CHANGE OF USE, EGRESS OR OCCUPANCY
X01323788-I1
11/24/2025
Special inspection requirement — Fire-Resistant Penetrations and Joints
NASHAT IBRAHIM
11/24/2025
Special inspection requirement — Energy Code Compliance Inspections
NASHAT IBRAHIM
11/24/2025
Special inspection requirement — Fenestration areas
NASHAT IBRAHIM
11/24/2025
Special inspection requirement — Fenestration air leakage
NASHAT IBRAHIM
11/24/2025
Special inspection requirement — Fenestration and door U-factor and product ratings
NASHAT IBRAHIM
11/24/2025
Special inspection requirement — Insulation placement and R values
NASHAT IBRAHIM
Permit / Filing Register
SourceWork TypeStatusApplicantIssued
DOB NOWPlumbingSigned-offINFINITI ESC PLUMBING COR02/02/2026
DOB NOWGeneral ConstructionSigned-offTHEORY 3 GROUP INC01/29/2026
1 project · most recent 02/05/2026
General Wiring
FiledStatusContractorScope
02/05/2026Permit IssuedBRANDL ELECTRIC INC.General Wiring
▾Field Inspections (DOB CAP) — 9
DateTypeResultReport
07/17/2026Pass-Final PL - Up to 9 Requested FloorsPassView ↗
04/17/2026Pass-Final General Construction Non-Directive 14PassView ↗
04/14/2026Pass-Final PL - Up to 3 Requested FloorsPassView ↗
04/07/2026Certified Water and Sanitary-WS-Fixtures-FinishCertifiedView ↗
03/04/2026Certified Water and Sanitary-WS-Sanitary Piping-RoughingCertifiedView ↗
03/04/2026Certified Water and Sanitary-WS-Sanitary Piping-UndergroundCertifiedView ↗
02/27/2026Certified Water and Sanitary-WS-Sanitary Piping-UndergroundCertifiedView ↗
02/26/2026Certified Remove/Cap - work done in accordance with codeCertifiedView ↗
02/12/2026Pass-Final PL - Up to 9 Requested FloorsPassView ↗
▾Special Inspection Requirements (DOB NOW) — 6
DateRequirementInspectorRole
11/24/2025Fire-Resistant Penetrations and JointsNASHAT IBRAHIMspecial
11/24/2025Energy Code Compliance InspectionsNASHAT IBRAHIMprogress
11/24/2025Fenestration areasNASHAT IBRAHIMenergy_progress
11/24/2025Fenestration air leakageNASHAT IBRAHIMenergy_progress
11/24/2025Fenestration and door U-factor and product ratingsNASHAT IBRAHIMenergy_progress
11/24/2025Insulation placement and R valuesNASHAT IBRAHIMenergy_progress
▾Documents — 12 on file (BIS + DOB NOW)
▸Plans & Drawings2
▸DOB NOWPlans/Sketch2
08/17/2026X01323788-I1Request digital key ↗
08/17/2026X01323858-I1Request digital key ↗
▸Seals & Professional Certifications8
▸DOB NOWProgress Inspector Seal & Signature5
08/31/2026X01323788-I1Open ↗
08/31/2026X01323788-I1Open ↗
08/31/2026X01323788-I1Open ↗
Showing 3 of 5 on file for this type
▸DOB NOWDPL-1: Design Professional Seal & Signature2
08/17/2026X01323858-I1Open ↗
08/13/2026X01323788-I1Open ↗
▸DOB NOWSpecial Inspector Seal & Signature1
08/31/2026X01323788-I1Open ↗
▸Environmental & Asbestos2
▸DOB NOWDEP ACP-5: Asbestos Assessment Report2
08/17/2026X01323858-I1Open ↗
08/13/2026X01323788-I1Open ↗