← Back
Two stories - detached, small or mid-size
4465 MUNDY LANE
BRONX · BIN 2071622
💬 Discuss this project
1930Year Built
2Stories
A1Building Class
R4Zoning
1,476 sfGross Floor Area
1Units
0 Open Violations
Two stories - detached, small or mid-size · 2,600 sf lot · 0.57 FAR built · Flood zone X
Locations of Work
ArchitectureElectrical
Roof2p · 1 filing · 6 docs
▾Sales History (ACRIS)
DatePriceUnitSeller → Buyer$/sf
01/28/2021$500K—Private party → Private party$339/sf building
06/26/2018$470K—NORTH ROSE, LLC. → Private party$318/sf building
11/01/2017$260K—— → —$176/sf building
▾Design Consultants (Architect / Engineer of Record)
FirmFilingsMost Recent
NY BUILDING ASSOCIATES INC105/13/2025
▾Contractors (License-Anchored)
FirmTradeRolesMost Recent
SURF CLEAN ENERGY INCGeneral Contractor303/21/2026
VINCENT POLIZZIElectrical103/21/2026
▾Special Inspection Agencies
AgencyLicense #FilingsMost Recent
NKM ENGINEERING PLLC6244105/13/2025
Building Lifecycle
All (11)Filed (1)Permit Issued (1)Violation (4)Special Inspection (5)
05/14/2025
Permit issued — Solar
X01221511-I1-SL
05/13/2025
Filed — Alteration
INSTALLATION OF SOLAR PANELS ON EXISTING ROOF. NO CHANGE IN USE, OCCUPANCY, OR EGRESS. NO CHANGE IN BULK
X01221511-I1
05/06/2025
Special inspection requirement — Fire-Resistant Penetrations and Joints
NARESH MAHANGU
05/06/2025
Special inspection requirement — Structural Stability – Alterations of existing buildings
NARESH MAHANGU
05/06/2025
Special inspection requirement — Energy Code Compliance Inspections
NARESH MAHANGU
05/06/2025
Special inspection requirement — Final
NARESH MAHANGU
05/06/2025
Special inspection requirement — Air barrier - visual inspection
NARESH MAHANGU
07/24/2013
Violation issued (ECB, closed)
Construction
03/11/2004
Violation issued (ECB, closed)
Quality of Life
08/01/2003
Violation issued (ECB, closed)
Construction
08/01/2003
Violation issued (ECB, closed)
Quality of Life
Permit / Filing Register
SourceWork TypeStatusApplicantIssued
DOB NOWSolarPermit IssuedSURF CLEAN ENERGY INC05/14/2025
1 project · most recent 05/12/2025
FiledStatusContractorScope
05/12/2025CompleteAMPACITY ELECTRICAL INC—
1 project · most recent 05/13/2025
FiledStatusContractorScope
05/13/2025Permit IssuedSURF CLEAN ENERGY INC15 panels, 6.37 kw, 11,178 roof_area_sqft
▾Special Inspection Requirements (DOB NOW) — 5
DateRequirementInspectorRole
05/06/2025Fire-Resistant Penetrations and JointsNARESH MAHANGUspecial
05/06/2025Structural Stability – Alterations of existing buildingsNARESH MAHANGUspecial
05/06/2025Energy Code Compliance InspectionsNARESH MAHANGUprogress
05/06/2025FinalNARESH MAHANGUprogress
05/06/2025Air barrier - visual inspectionNARESH MAHANGUenergy_progress
▾Documents — 15 on file (BIS + DOB NOW)
▸Plans & Drawings1
▸DOB NOWPlans/Sketch1
08/19/2026X01221511-I1Request digital key ↗
▸Applications & Permits2
▸BISPLAN / WORK APPROVAL APPLICATION2
11/23/2020220337455Open ↗
09/27/2013220337455Open ↗
▸Seals & Professional Certifications7
▸DOB NOWProgress Inspector Seal & Signature2
08/27/2026X01221511-I1Open ↗
08/27/2026X01221511-I1Open ↗
▸BISPROFESSIONAL CERTIFICATION STATEMENT1
09/27/2013220337455Open ↗
▸BISPROFESSIONAL CERTIFIED CHECKLIST1
09/27/2013220337455Open ↗
▸BISTECHNICAL REPORT: RESPONSIBILITY/CERTIFICATION1
09/27/2013220337455Open ↗
▸DOB NOWDPL-1: Design Professional Seal & Signature1
08/13/2026X01221511-I1Open ↗
▸DOB NOWSpecial Inspector Seal & Signature1
08/27/2026X01221511-I1Open ↗
▸Trade Schedules & Equipment1
▸BISSCHEDULE B - PLUMBING1
09/27/2013220337455Open ↗
▸Environmental & Asbestos2
▸BISASBESTOS: CERTIFICATION (DEP ACP5)1
09/30/2013220337455Open ↗
▸DOB NOWDEP ACP-5: Asbestos Assessment Report1
08/13/2026X01221511-I1Open ↗
▸Cost, Insurance & Ownership1
▸BISCOST AFFIDAVIT1
09/27/2013220337455Open ↗
▸Filing & Intake Forms1
▸BISEFILING COVER SHEET1
09/27/2013220337455Open ↗