Two family brick
45-08 11 STREET
QUEENS · BIN 4000417
💬 Discuss this project
1911Year Built
2Stories
B1Building Class
M1-4/R6BZoning
1,620 sfGross Floor Area
2Units
1 Open Violation ▸FDNY Report ↗
Two family brick · 1,942 sf lot · 0.83 FAR built · Flood zone X500
Locations of Work
Architecture
Floor 21p · 1 filing · 18 docs
Floor 11p · 1 filing · 18 docs
▾Sales History (ACRIS)
DatePriceUnitSeller → Buyer$/sf
11/01/2022$1.6M—Private party → Private party$988/sf building
▾Design Consultants (Architect / Engineer of Record)
FirmFilingsMost Recent
CARUSONE & CHERRES ARCHITECTS, LLC803/18/2024
▾Filing Representatives (Expediters)
RepresentativeFilingsMost Recent
AB WORKS PROCESSING803/21/2026
▾Contractors (License-Anchored)
FirmTradeRolesMost Recent
JP GENERAL CONTRACTING &General Contractor603/21/2026
RIZE CONSTRUCTION LLCGeneral Contractor407/08/2026
ARANDA PLBG & HTG CORPPlumbing107/08/2026
JUST PLBG & HTG INCPlumbing107/08/2026
▾Special Inspection Agencies
AgencyLicense #FilingsMost Recent
DAVI ARCHITECTURE, PC5168703/18/2024
Building Lifecycle
All (53)Filed (8)Permit Issued (6)Signed Off (3)Violation (1)Inspection (5)Special Inspection (30)
11/14/2024
Signed off — Alteration
INTERIOR RENOVATION AND INSTALLING A DECK AT THE BACK OF THIS BUILDING.
Q00822375-S1
11/14/2024
Signed off — Alteration
INTERIOR RENOVATION AND INSTALLING A DECK AT THE BACK OF THIS BUILDING.
Q00822375-I1
03/18/2024
Filed — Alteration
INTERIOR RENOVATION AND INSTALLING A DECK AT THE BACK OF THIS BUILDING.
Q00822375-P5
07/27/2023
Inspection — Pass-Final PL - Up to 3 Requested Floors
Pass
View inspection ↗
07/26/2023
Filed — Alteration
INTERIOR RENOVATION AND INSTALLING A DECK AT THE BACK OF THIS BUILDING.
Q00822375-P4
07/20/2023
Special inspection requirement — Energy Code Compliance Inspections
JORGE CHERRES
07/20/2023
Special inspection requirement — HVAC-R and service water piping design and insulation
JORGE CHERRES
07/20/2023
Special inspection requirement — Maintenance information
JORGE CHERRES
07/20/2023
Special inspection requirement — HVAC-R and service water heating equipment
JORGE CHERRES
07/20/2023
Special inspection requirement — HVAC-R and service water heating system controls
JORGE CHERRES
07/20/2023
Special inspection requirement — Fire-Resistant Penetrations and Joints
Benedetto Davi
07/19/2023
Inspection — Pass-Final PL - Up to 3 Requested Floors
Pass
View inspection ↗
07/18/2023
Signed off — Alteration
PROPOSED INSTALLATION OF FENCE @ 45-08 11 ST.
Q00820834-I1
07/14/2023
Filed — Alteration
INTERIOR RENOVATION AND INSTALLING A DECK AT THE BACK OF THIS BUILDING.
Q00822375-P2
07/13/2023
Filed — Alteration
INTERIOR RENOVATION AND INSTALLING A DECK AT THE BACK OF THIS BUILDING.
Q00822375-P3
06/14/2023
Special inspection requirement — Fenestration and door U-factor and product ratings
JORGE CHERRES
06/14/2023
Special inspection requirement — Fenestration air leakage
JORGE CHERRES
06/14/2023
Special inspection requirement — Insulation placement and R values
JORGE CHERRES
06/14/2023
Special inspection requirement — Fenestration areas
JORGE CHERRES
06/14/2023
Special inspection requirement — Air barrier - visual inspection
JORGE CHERRES
06/14/2023
Special inspection requirement — HVAC-R and service water heating system controls
JORGE CHERRES
06/14/2023
Special inspection requirement — Fire-Resistant Penetrations and Joints
Benedetto Davi
06/14/2023
Special inspection requirement — Structural Stability – Alterations of existing buildings
Benedetto Davi
06/14/2023
Special inspection requirement — Energy Code Compliance Inspections
JORGE CHERRES
06/14/2023
Special inspection requirement — Final
JORGE CHERRES
06/14/2023
Special inspection requirement — Fire-Resistance Rated Construction
JORGE CHERRES
06/14/2023
Special inspection requirement — Fire-Resistant Penetrations and Joints
Benedetto Davi
06/14/2023
Special inspection requirement — Energy Code Compliance Inspections
JORGE CHERRES
06/14/2023
Special inspection requirement — HVAC-R and service water piping design and insulation
JORGE CHERRES
06/14/2023
Special inspection requirement — Maintenance information
JORGE CHERRES
06/14/2023
Special inspection requirement — HVAC-R and service water heating equipment
JORGE CHERRES
05/22/2023
Inspection — Pass-Final PL - Up to 3 Requested Floors
Pass
View inspection ↗
04/26/2023
Inspection — Certified Gas-Gas-Piping-Roughing
Certified
View inspection ↗
04/26/2023
Inspection — Certified Water and Sanitary-WS-Sanitary Piping-Roughing
Certified
View inspection ↗
04/21/2023
Permit issued — General Construction
Q00822375-I1-GC
04/13/2023
Filed — Alteration
INTERIOR RENOVATION AND INSTALLING A DECK AT THE BACK OF THIS BUILDING.
Q00822375-P1
03/31/2023
Permit issued — Plumbing
Q00822375-S1-PL
03/30/2023
Special inspection requirement — Insulation placement and R values
JORGE CHERRES
03/30/2023
Special inspection requirement — Fenestration and door U-factor and product ratings
JORGE CHERRES
03/30/2023
Special inspection requirement — Fenestration areas
JORGE CHERRES
03/30/2023
Special inspection requirement — Fenestration air leakage
JORGE CHERRES
03/30/2023
Special inspection requirement — Fire-Resistant Penetrations and Joints
Benedetto Davi
03/30/2023
Special inspection requirement — Structural Stability – Alterations of existing buildings
Benedetto Davi
03/30/2023
Special inspection requirement — Energy Code Compliance Inspections
JORGE CHERRES
03/30/2023
Special inspection requirement — Final
JORGE CHERRES
02/15/2023
Permit issued — Plumbing
Q00822375-S1-PL
02/15/2023
Permit issued — General Construction
Q00822375-I1-GC
02/09/2023
Filed — Alteration
INTERIOR RENOVATION AND INSTALLING A DECK AT THE BACK OF THIS BUILDING.
Q00822375-S1
02/07/2023
Filed — Alteration
INTERIOR RENOVATION AND INSTALLING A DECK AT THE BACK OF THIS BUILDING.
Q00822375-I1
02/06/2023
Permit issued — Construction Fence
Q00820834-I1-FN
02/06/2023
Violation issued (DOB, open)
V-DOB VIOLATION - ACTIVE
01/31/2023
Permit issued — Construction Fence
Q00820834-I1-FN
01/30/2023
Filed — Alteration
PROPOSED INSTALLATION OF FENCE @ 45-08 11 ST.
Q00820834-I1
Permit / Filing Register
SourceWork TypeStatusApplicantIssued
DOB NOWGeneral ConstructionSigned-offRIZE CONSTRUCTION LLC04/21/2023
DOB NOWPlumbingSigned-offARANDA PLBG & HTG CORP03/31/2023
DOB NOWPlumbingSigned-offMOHAMED ABDELRAZEK02/15/2023
DOB NOWGeneral ConstructionSigned-offJP GENERAL CONTRACTING &02/15/2023
DOB NOWConstruction FenceSigned-offJP GENERAL CONTRACTING &02/06/2023
DOB NOWConstruction FenceSigned-offRIZE CONSTRUCTION LLC01/31/2023
1 project · most recent 08/14/2023
General Wiring Lighting
FiledStatusContractorScope
08/14/2023Permit IssuedY.S ELECTRICGeneral Wiring, Lighting
▾Field Inspections (DOB CAP) — 5
DateTypeResultReport
07/27/2023Pass-Final PL - Up to 3 Requested FloorsPassView ↗
07/19/2023Pass-Final PL - Up to 3 Requested FloorsPassView ↗
05/22/2023Pass-Final PL - Up to 3 Requested FloorsPassView ↗
04/26/2023Certified Gas-Gas-Piping-RoughingCertifiedView ↗
04/26/2023Certified Water and Sanitary-WS-Sanitary Piping-RoughingCertifiedView ↗
▾Special Inspection Requirements (DOB NOW) — 32
DateRequirementInspectorRole
07/20/2023Energy Code Compliance InspectionsJORGE CHERRESprogress
07/20/2023HVAC-R and service water piping design and insulationJORGE CHERRESenergy_progress
07/20/2023Maintenance informationJORGE CHERRESenergy_progress
07/20/2023HVAC-R and service water heating equipmentJORGE CHERRESenergy_progress
07/20/2023HVAC-R and service water heating system controlsJORGE CHERRESenergy_progress
07/20/2023Fire-Resistant Penetrations and JointsBenedetto Davispecial
06/14/2023Fenestration and door U-factor and product ratingsJORGE CHERRESenergy_progress
06/14/2023Fenestration air leakageJORGE CHERRESenergy_progress
06/14/2023Insulation placement and R valuesJORGE CHERRESenergy_progress
06/14/2023Fenestration areasJORGE CHERRESenergy_progress
06/14/2023Air barrier - visual inspectionJORGE CHERRESenergy_progress
06/14/2023HVAC-R and service water heating system controlsJORGE CHERRESenergy_progress
06/14/2023Fire-Resistant Penetrations and JointsBenedetto Davispecial
06/14/2023Structural Stability – Alterations of existing buildingsBenedetto Davispecial
06/14/2023Energy Code Compliance InspectionsJORGE CHERRESprogress
06/14/2023FinalJORGE CHERRESprogress
06/14/2023Fire-Resistance Rated ConstructionJORGE CHERRESprogress
06/14/2023Fire-Resistant Penetrations and JointsBenedetto Davispecial
06/14/2023Energy Code Compliance InspectionsJORGE CHERRESprogress
06/14/2023HVAC-R and service water piping design and insulationJORGE CHERRESenergy_progress
06/14/2023Maintenance informationJORGE CHERRESenergy_progress
06/14/2023HVAC-R and service water heating equipmentJORGE CHERRESenergy_progress
03/30/2023Insulation placement and R valuesJORGE CHERRESenergy_progress
03/30/2023Fenestration and door U-factor and product ratingsJORGE CHERRESenergy_progress
03/30/2023Fenestration areasJORGE CHERRESenergy_progress
Latest 25 of 32.
▾Documents — 20 on file (BIS + DOB NOW)
▸Plans & Drawings1
▸DOB NOWPlans/Sketch1
08/25/2026Q00820834-I1Request digital key ↗
▸Seals & Professional Certifications17
▸DOB NOWProgress Inspector Seal & Signature8
09/02/2026Q00822375-P4Open ↗
09/02/2026Q00822375-P4Open ↗
08/26/2026Q00822375-P1Open ↗
Showing 3 of 8 on file for this type
▸DOB NOWSpecial Inspector Seal & Signature6
09/02/2026Q00822375-P4Open ↗
08/26/2026Q00822375-P1Open ↗
08/26/2026Q00822375-P1Open ↗
Showing 3 of 6 on file for this type
▸DOB NOWDPL-1: Design Professional Seal & Signature3
08/13/2026Q00822375-P2Open ↗
08/13/2026Q00820834-I1Open ↗
08/13/2026Q00822375-P5Open ↗
▸Environmental & Asbestos2
▸DOB NOWDEP ACP-5: Asbestos Assessment Report2
08/13/2026Q00822375-P5Open ↗
08/13/2026Q00822375-P2Open ↗