← Back
Two stories - detached, small or mid-size
45-10 166 STREET
QUEENS · East Flushing · BIN 4123381
💬 Discuss this project
1935Year Built
2Stories
A1Building Class
R2AZoning
1,404 sfGross Floor Area
1Units
Two stories - detached, small or mid-size · 3,800 sf lot · 0.37 FAR built · Flood zone X
Locations of Work
ArchitecturePlumbing
Floor 21p · 1 filing · 3 docs
Floor 1
Cellar2p · 1 filing · 8 docs
▾Sales History (ACRIS)
DatePriceUnitSeller → Buyer$/sf
09/08/2022$1.0M—Private party → Private party$725/sf building
06/27/2017$835K—Private party → Private party$595/sf building
▾Design Consultants (Architect / Engineer of Record)
FirmFilingsMost Recent
MEHDI GHAZI, P.E., P.C.312/20/2022
▾Filing Representatives (Expediters)
RepresentativeFilingsMost Recent
IBUILD CONSULTING603/21/2026
▾Contractors (License-Anchored)
FirmTradeRolesMost Recent
L&L CONSTRUCTION DEVELOPGeneral Contractor303/21/2026
ROCK E SMALL PLBG&HTG INCPlumbing107/08/2026
▾Special Inspection Agencies
AgencyLicense #FilingsMost Recent
MEHDI GHAZI, P.E. P.C.7129312/20/2022
Building Lifecycle
All (17)Filed (3)Permit Issued (2)Signed Off (2)Inspection (6)Special Inspection (4)
03/10/2023
Signed off — Alteration
INTERIOR RENOVATION FOR EXISTING SINGLE-FAMILY DETACHED RESIDENCE AS PER PLAN FILED HEREWITH. NO CHANGE IN USE, OCCUPANCY OR EGRESS.
Q08018398-I1
02/21/2023
Signed off — Alteration
Q08018454-I1
01/04/2023
Inspection — Pass-Final General Construction Non-Directive 14
Pass
View inspection ↗
12/21/2022
Special inspection requirement — Concrete - Cast-In-Place
MEHDI GHAZI
12/21/2022
Special inspection requirement — Fire-Resistant Penetrations and Joints
MEHDI GHAZI
12/20/2022
Filed — Alteration
INTERIOR RENOVATION FOR EXISTING SINGLE-FAMILY DETACHED RESIDENCE AS PER PLAN FILED HEREWITH. NO CHANGE IN USE, OCCUPANCY OR EGRESS.
Q08018398-P1
12/20/2022
Special inspection requirement — Concrete - Cast-In-Place
MEHDI GHAZI
12/20/2022
Special inspection requirement — Fire-Resistant Penetrations and Joints
MEHDI GHAZI
12/19/2022
Inspection — Certified Water and Sanitary-WS-Fixtures-Finish
Certified
View inspection ↗
11/18/2022
Inspection — Certified Gas-Gas-Piping-Roughing
Certified
View inspection ↗
11/18/2022
Inspection — Certified Water and Sanitary-WS-Sanitary Piping-Roughing
Certified
View inspection ↗
11/18/2022
Inspection — Certified Water and Sanitary-WS-Sanitary Piping-Underground
Certified
View inspection ↗
11/16/2022
Inspection — Certified Remove/Cap - work done in accordance with code
Certified
View inspection ↗
10/18/2022
Permit issued — Plumbing
Q08018454-I1-PL
10/18/2022
Permit issued — General Construction
Q08018398-I1-GC
10/14/2022
Filed — Alteration
INTERIOR RENOVATION FOR EXISTING SINGLE-FAMILY DETACHED RESIDENCE AS PER PLAN FILED HEREWITH. NO CHANGE IN USE, OCCUPANCY OR EGRESS.
Q08018398-I1
10/14/2022
Filed — Alteration
Q08018454-I1
Permit / Filing Register
SourceWork TypeStatusApplicantIssued
DOB NOWPlumbingSigned-offROCK E SMALL PLBG&HTG INC10/18/2022
DOB NOWGeneral ConstructionSigned-offL&L CONSTRUCTION DEVELOP10/18/2022
1 project · most recent 01/09/2023
General Wiring
FiledStatusContractorScope
01/09/2023CompleteRIGHTWAY ELECTRICAL INCGeneral Wiring
▾Field Inspections (DOB CAP) — 6
DateTypeResultReport
01/04/2023Pass-Final General Construction Non-Directive 14PassView ↗
12/19/2022Certified Water and Sanitary-WS-Fixtures-FinishCertifiedView ↗
11/18/2022Certified Gas-Gas-Piping-RoughingCertifiedView ↗
11/18/2022Certified Water and Sanitary-WS-Sanitary Piping-RoughingCertifiedView ↗
11/18/2022Certified Water and Sanitary-WS-Sanitary Piping-UndergroundCertifiedView ↗
11/16/2022Certified Remove/Cap - work done in accordance with codeCertifiedView ↗
▾Special Inspection Requirements (DOB NOW) — 4
DateRequirementInspectorRole
12/21/2022Concrete - Cast-In-PlaceMEHDI GHAZIspecial
12/21/2022Fire-Resistant Penetrations and JointsMEHDI GHAZIspecial
12/20/2022Concrete - Cast-In-PlaceMEHDI GHAZIspecial
12/20/2022Fire-Resistant Penetrations and JointsMEHDI GHAZIspecial
▾Documents — 11 on file (BIS + DOB NOW)
▸Plans & Drawings3
▸DOB NOWPlans/Sketch3
08/25/2026Q08018454-I1Request digital key ↗
08/25/2026Q08018398-I1Request digital key ↗
08/25/2026Q08018398-P1Request digital key ↗
▸Seals & Professional Certifications5
▸DOB NOWDPL-1: Design Professional Seal & Signature3
08/25/2026Q08018454-I1Open ↗
08/25/2026Q08018398-I1Open ↗
08/25/2026Q08018398-P1Open ↗
▸DOB NOWSpecial Inspector Seal & Signature2
09/28/2026Q08018398-I1Open ↗
08/24/2026Q08018398-P1Open ↗
▸Environmental & Asbestos3
▸DOB NOWDEP ACP-5: Asbestos Assessment Report3
08/25/2026Q08018454-I1Open ↗
08/25/2026Q08018398-I1Open ↗
08/25/2026Q08018398-P1Open ↗