← Back
Two family brick
45-10 PEARSON STREET
QUEENS · BIN 4000730
💬 Discuss this project
1880Year Built
3Stories
B1Building Class
M1-5/R7-3Zoning
1,920 sfGross Floor Area
2Units
2 Open Violations 0 unresolved · 2 paperwork only ▸FDNY Report ↗
Two family brick · 1,650 sf lot · 1.16 FAR built · Flood zone X500
Locations of Work
ArchitectureGeneral
Roof2p · 1 filing · 8 docs
▾Design Consultants (Architect / Engineer of Record)
FirmFilingsMost Recent
TOM PETERSEN ARCHITECT, LLC105/30/2024
▾Filing Representatives (Expediters)
RepresentativeFilingsMost Recent
SUNCO CAPITAL203/21/2026
▾Contractors (License-Anchored)
FirmTradeRolesMost Recent
BERGER QUALITY ELEC'L CONElectrical103/22/2026
SUNCO CAPITAL LLCGeneral Contractor107/08/2026
▾Special Inspection Agencies
AgencyLicense #FilingsMost Recent
THOMAS PETERSEN ARCHITECT7854105/30/2024
Building Lifecycle
All (12)Filed (1)Permit Issued (1)Signed Off (1)Violation (3)Special Inspection (6)
11/06/2024
Signed off — Alteration
INSTALLATION OF SOLAR PANELS ON ROOF. NO CHANGE IN USE, EGRESS, OR OCCUPANCY.
Q01051481-I1
08/01/2024
Permit issued — Solar
Q01051481-I1-SL
05/30/2024
Filed — Alteration
INSTALLATION OF SOLAR PANELS ON ROOF. NO CHANGE IN USE, EGRESS, OR OCCUPANCY.
Q01051481-I1
05/30/2024
Special inspection requirement — Flood Zone Compliance (attach FEMA elevation/dry floodproofing certificate where applicable)
TOM PETERSEN
05/15/2024
Special inspection requirement — Fire-Resistant Penetrations and Joints
TOM PETERSEN
05/15/2024
Special inspection requirement — Structural Stability – Alterations of existing buildings
TOM PETERSEN
05/15/2024
Special inspection requirement — Energy Code Compliance Inspections
TOM PETERSEN
05/15/2024
Special inspection requirement — Final
TOM PETERSEN
05/15/2024
Special inspection requirement — Air barrier - visual inspection
TOM PETERSEN
04/07/2022
Violation issued (ECB, open)
Construction
11/27/2018
Violation issued (ECB, open)
Zoning
09/27/2018
Violation issued (ECB, closed)
Zoning
Permit / Filing Register
SourceWork TypeStatusApplicantIssued
DOB NOWSolarSigned-offSUNCO CAPITAL LLC08/01/2024
1 project · most recent 07/29/2024
FiledStatusContractorScope
07/29/2024CompleteBERGER QUALITY ELEC'L CON—
▾Special Inspection Requirements (DOB NOW) — 6
DateRequirementInspectorRole
05/30/2024Flood Zone Compliance (attach FEMA elevation/dry floodproofing certificate where applicable)TOM PETERSENspecial
05/15/2024Fire-Resistant Penetrations and JointsTOM PETERSENspecial
05/15/2024Structural Stability – Alterations of existing buildingsTOM PETERSENspecial
05/15/2024Energy Code Compliance InspectionsTOM PETERSENprogress
05/15/2024FinalTOM PETERSENprogress
05/15/2024Air barrier - visual inspectionTOM PETERSENenergy_progress
▾Documents — 8 on file (BIS + DOB NOW)
▸Plans & Drawings1
▸DOB NOWPlans/Sketch1
08/22/2026Q01051481-I1Request digital key ↗
▸Seals & Professional Certifications5
▸DOB NOWProgress Inspector Seal & Signature2
09/01/2026Q01051481-I1Open ↗
09/01/2026Q01051481-I1Open ↗
▸DOB NOWSpecial Inspector Seal & Signature2
09/01/2026Q01051481-I1Open ↗
09/01/2026Q01051481-I1Open ↗
▸DOB NOWDPL-1: Design Professional Seal & Signature1
08/13/2026Q01051481-I1Open ↗
▸Environmental & Asbestos1
▸DOB NOWDEP ACP-5: Asbestos Assessment Report1
08/13/2026Q01051481-I1Open ↗
▸Approvals, Objections & Sign-offs1
▸DOB NOWUtility Company Final Acceptance Letter1
08/13/2026Q01051481-I1Open ↗