| Owner | Filings | Most Recent |
|---|---|---|
| HT Builds LLC 1 | 1 | 03/22/2026 |
| Date | Price | Unit | Seller → Buyer | $/sf |
|---|---|---|---|---|
| 11/02/2022 | $1.1M | — | — → — | — not available |
| Firm | Filings | Most Recent |
|---|---|---|
| HT Associates | 5 | 06/23/2025 |
| John C. Chen Architect | 4 | 02/16/2024 |
| Representative | Filings | Most Recent |
|---|---|---|
| HT Associates | 5 | 03/21/2026 |
| Firm | Trade | Roles | Most Recent |
|---|---|---|---|
| L&L Construction Development | General Contractor | 5 | 07/08/2026 |
| HT Builds | General Contractor | 2 | 09/01/2026 |
| HT Builds | Scaffold | 2 | 07/08/2026 |
| Village P & H NY | Plumbing | 2 | 07/08/2026 |
| Robin Electrical Co | Electrical | 1 | 03/22/2026 |
| Agency | License # | Filings | Most Recent |
|---|---|---|---|
| John C Chen Architect, PL | 2205 | 4 | 06/23/2025 |
| Building Consulting Engineering | 1034 | 1 | 06/16/2023 |
| Flushing Engineering Service | 4373 | 2 | 06/16/2023 |
| Source | Work Type | Status | Applicant | Issued |
|---|---|---|---|---|
| DOB NOW | Mechanical Systems | Signed-off | HT Builds | 08/31/2026 |
| DOB NOW | Earth Work | Permit Issued | L&L Construction Development | 08/18/2025 |
| DOB NOW | Curb Cut | Signed-off | HT Builds | 02/11/2025 |
| DOB NOW | Structural | Permit Issued | L&L Construction Development | 07/23/2024 |
| DOB NOW | Construction Fence | Signed-off | HT Builds | 06/27/2024 |
| DOB NOW | Plumbing | Signed-off | Village P & H NY | 06/27/2024 |
| DOB NOW | Mechanical Systems | Permit Issued | L&L Construction Development | 07/25/2023 |
| DOB NOW | Construction Fence | Signed-off | HT Builds | 07/06/2023 |
| DOB NOW | Plumbing | Signed-off | Village P & H NY | 07/06/2023 |
| Filed | Status | Contractor | Scope | Make / Model / Capacity |
|---|---|---|---|---|
| 06/23/2025 | Signed-off | HT Builds | Air Conditioning Systems, Heating Systems | Cooling Goodman GSX140361 3 tons · Condensing Unit ×6 Heating Williamson GWA-140-N-T 140,000 BTU · Boiler ×6 |
| Filed | Status | Contractor | Scope |
|---|---|---|---|
| 06/16/2023 | Signed-off | Village P & H NY | Gas, Storm, Water/Sanitary |
| Filed | Status | Contractor | Scope |
|---|---|---|---|
| 04/01/2024 | Complete | Robin Electrical Co | General Wiring |
| 01/11/2024 | Complete | Robin Electrical Co | — |
| Filed | Status | Contractor | Scope |
|---|---|---|---|
| 06/23/2025 | Signed-off | HT Builds | Steel, Concrete, Masonry, Wood |
| Date | Type | Result | Report |
|---|---|---|---|
| 07/30/2026 | Pass-Final CND-Occupancy Inspection | Pass | View ↗ |
| 07/08/2026 | Pass-Final CND-Occupancy Inspection | Pass | View ↗ |
| 05/09/2024 | Certified Gas-Gas-Piping-Roughing | Certified | View ↗ |
| 05/09/2024 | Certified Storm Drainage-ST-Piping-Underground | Certified | View ↗ |
| 05/09/2024 | Certified Water and Sanitary-WS-Sanitary Piping-Roughing | Certified | View ↗ |
| 05/09/2024 | Certified Water and Sanitary-WS-Sanitary Piping-Underground | Certified | View ↗ |
| 05/06/2024 | Certified Remove/Cap - work done in accordance with code | Certified | View ↗ |
| Date | Requirement | Inspector | Role |
|---|---|---|---|
| 08/11/2025 | Permanent certificate | JOHN CHEN | energy_progress |
| 08/11/2025 | Fire-Resistant Penetrations and Joints | JOHN CHEN | special |
| 08/11/2025 | Mechanical Systems | JOHN CHEN | special |
| 08/11/2025 | Masonry | JOHN CHEN | special |
| 08/11/2025 | Concrete - Cast-In-Place | JOHN CHEN | special |
| 08/11/2025 | Heating Systems | JOHN CHEN | special |
| 08/11/2025 | Structural Steel - High Strength Bolting | JOHN CHEN | special |
| 08/11/2025 | Subsurface Conditions – Fill Placement & In-Place Density | JOHN CHEN | special |
| 08/11/2025 | Structural Stability – Alterations of existing buildings | JOHN CHEN | special |
| 08/11/2025 | Structural Steel - Details | JOHN CHEN | special |
| 08/11/2025 | Structural Steel - Welding | JOHN CHEN | special |
| 08/11/2025 | Private On-Site Storm Water Disposal Systems-, and Detention Facilities, Installation | JOHN CHEN | special |
| 08/11/2025 | Excavations - Sheeting, Shoring, and Bracing | JOHN CHEN | special |
| 08/11/2025 | Final | JOHN CHEN | progress |
| 08/11/2025 | Footing and Foundation | JOHN CHEN | progress |
| 08/11/2025 | Energy Code Compliance Inspections | JOHN CHEN | progress |
| 08/11/2025 | Fire-Resistance Rated Construction | JOHN CHEN | progress |
| 08/11/2025 | Maintenance information | JOHN CHEN | energy_progress |
| 08/11/2025 | Fenestration air leakage | JOHN CHEN | energy_progress |
| 08/11/2025 | Air barrier - visual inspection | JOHN CHEN | energy_progress |
| 08/11/2025 | HVAC-R and service water piping design and insulation | — | energy_progress |
| 08/11/2025 | Ventilation and air distribution system | — | energy_progress |
| 08/11/2025 | Insulation placement and R values | JOHN CHEN | energy_progress |
| 08/11/2025 | Interior lighting power | JOHN CHEN | energy_progress |
| 08/11/2025 | Subgrade Inspections | JOHN CHEN | special |