← Back
One family attached or semi-detached
45-43 215TH STREET
QUEENS · BIN 4157433
💬 Discuss this project
1955Year Built
2Stories
A5Building Class
R4BZoning
1,114 sfGross Floor Area
1Units
0 Open ViolationsFDNY Report ↗
One family attached or semi-detached · 1,845 sf lot · 0.6 FAR built · Flood zone X
Locations of Work
Plumbing
Cellar1p · 1 filing · 20 docs
▾Owner History (Filing Record)
Companies and organizations named on filings. Individual owners are not shown.
OwnerFilingsMost Recent
DFE CONTRACTOR203/22/2026
▾Sales History (ACRIS)
DatePriceUnitSeller → Buyer$/sf
06/22/2023$998K—Private party → Private party$896/sf building
05/08/2019$915K—— → —$821/sf building
▾Design Consultants (Architect / Engineer of Record)
FirmFilingsMost Recent
AN SHEN MA ARCHITECT407/02/2021
▾Contractors (License-Anchored)
FirmTradeRolesMost Recent
DFE CONTRACTOR LLCGeneral Contractor207/08/2026
DOVAL PLBG & HTG CORPPlumbing207/08/2026
▾Special Inspection Agencies
AgencyLicense #FilingsMost Recent
AN SHEN MA ARCHITECT2968307/02/2021
REGIONAL TESTING CORP.394307/02/2021
Building Lifecycle
All (29)Filed (4)Permit Issued (4)Signed Off (2)Violation (3)Special Inspection (16)
12/22/2021
Signed off — Alteration
TO INSTALL, REPLACE OR RELOCATE PLUMBING FIXTURES IN ALTERED 2 STORY 2 FAMILY DWELLING. FILED IN CONJUNCTION W/ ALT 1 #421906968. NO CHANGE OF USE, EGRESS OR OCCUPANCY.
Q00242757-I1
07/14/2021
Signed off — Alteration
TO INSTALL TEMPORARY CONSTRUCTION FENCE IN CONJUNCTION W/ ALT 1 #421906968. NO CHANGE OF USE, EGRESS OR OCCUPANCY.
Q00242756-I1
07/09/2021
Permit issued — Plumbing
Q00242757-I1-PL
07/07/2021
Special inspection requirement — Soil Percolation Test - Private On-Site Storm Water Drainage Disposal Systems, and Detention Facilities
Paul Raymond
07/07/2021
Special inspection requirement — Fire-Resistant Penetrations and Joints
AN MA
07/07/2021
Special inspection requirement — Private On-Site Storm Water Disposal Systems-, and Detention Facilities, Installation
AN MA
07/07/2021
Special inspection requirement — Energy Code Compliance Inspections
AN MA
07/07/2021
Special inspection requirement — HVAC insulation and sealing
AN MA
07/02/2021
Filed — Alteration
TO INSTALL, REPLACE OR RELOCATE PLUMBING FIXTURES IN ALTERED 2 STORY 2 FAMILY DWELLING. FILED IN CONJUNCTION W/ ALT 1 #421906968. NO CHANGE OF USE, EGRESS OR OCCUPANCY.
Q00242757-P2
06/23/2021
Special inspection requirement — Fire-Resistant Penetrations and Joints
AN MA
06/23/2021
Special inspection requirement — Private On-Site Storm Water Disposal Systems-, and Detention Facilities, Installation
AN MA
06/23/2021
Special inspection requirement — Soil Percolation Test - Private On-Site Storm Water Drainage Disposal Systems, and Detention Facilities
Paul Raymond
06/23/2021
Special inspection requirement — Energy Code Compliance Inspections
AN MA
06/23/2021
Special inspection requirement — HVAC insulation and sealing
AN MA
02/17/2021
Violation issued (DOB, closed)
V*-DOB VIOLATION - DISMISSED
11/18/2020
Violation issued (ECB, closed)
Construction
11/18/2020
Violation issued (ECB, closed)
Construction
10/29/2020
Filed — Alteration
TO INSTALL, REPLACE OR RELOCATE PLUMBING FIXTURES IN ALTERED 2 STORY 2 FAMILY DWELLING. FILED IN CONJUNCTION W/ ALT 1 #421906968. NO CHANGE OF USE, EGRESS OR OCCUPANCY.
Q00242757-P1
10/13/2020
Permit issued — Construction Fence
Q00242756-I1-FN
10/08/2020
Permit issued — Plumbing
Q00242757-I1-PL
09/24/2020
Special inspection requirement — Fire-Resistant Penetrations and Joints
AN MA
09/24/2020
Special inspection requirement — Private On-Site Storm Water Disposal Systems-, and Detention Facilities, Installation
AN MA
09/24/2020
Special inspection requirement — Soil Percolation Test - Private On-Site Storm Water Drainage Disposal Systems, and Detention Facilities
Paul Raymond
09/24/2020
Special inspection requirement — Energy Code Compliance Inspections
AN MA
09/24/2020
Special inspection requirement — HVAC insulation and sealing
AN MA
09/01/2020
Permit issued — Construction Fence
Q00242756-I1-FN
02/25/2020
Filed — Alteration
TO INSTALL, REPLACE OR RELOCATE PLUMBING FIXTURES IN ALTERED 2 STORY 2 FAMILY DWELLING. FILED IN CONJUNCTION W/ ALT 1 #421906968. NO CHANGE OF USE, EGRESS OR OCCUPANCY.
Q00242757-I1
12/10/2019
Filed — Alteration
TO INSTALL TEMPORARY CONSTRUCTION FENCE IN CONJUNCTION W/ ALT 1 #421906968. NO CHANGE OF USE, EGRESS OR OCCUPANCY.
Q00242756-I1
10/08/2019
Special inspection requirement — Final
AN MA
Permit / Filing Register
SourceWork TypeStatusApplicantIssued
DOB NOWPlumbingSigned-offDOVAL PLBG & HTG CORP07/09/2021
DOB NOWConstruction FenceSigned-offDFE CONTRACTOR LLC10/13/2020
DOB NOWPlumbingSigned-offDOVAL PLBG & HTG CORP10/08/2020
DOB NOWConstruction FenceSigned-offDFE CONTRACTOR LLC09/01/2020
BIS—ISSUEDDFE CONTRACTOR LLC10/15/2020
BIS—ISSUEDDFE CONTRACTOR LLC09/10/2020
1 project · most recent 09/24/2020
General Wiring
FiledStatusContractorScope
09/24/2020CompleteWCK ELECTRIC CORP.General Wiring
▾Special Inspection Requirements (DOB NOW) — 16
DateRequirementInspectorRole
07/07/2021Soil Percolation Test - Private On-Site Storm Water Drainage Disposal Systems, and Detention FacilitiesPaul Raymondspecial
07/07/2021Fire-Resistant Penetrations and JointsAN MAspecial
07/07/2021Private On-Site Storm Water Disposal Systems-, and Detention Facilities, InstallationAN MAspecial
07/07/2021Energy Code Compliance InspectionsAN MAprogress
07/07/2021HVAC insulation and sealing AN MAenergy_progress
06/23/2021Fire-Resistant Penetrations and JointsAN MAspecial
06/23/2021Private On-Site Storm Water Disposal Systems-, and Detention Facilities, InstallationAN MAspecial
06/23/2021Soil Percolation Test - Private On-Site Storm Water Drainage Disposal Systems, and Detention FacilitiesPaul Raymondspecial
06/23/2021Energy Code Compliance InspectionsAN MAprogress
06/23/2021HVAC insulation and sealing AN MAenergy_progress
09/24/2020Fire-Resistant Penetrations and JointsAN MAspecial
09/24/2020Private On-Site Storm Water Disposal Systems-, and Detention Facilities, InstallationAN MAspecial
09/24/2020Soil Percolation Test - Private On-Site Storm Water Drainage Disposal Systems, and Detention FacilitiesPaul Raymondspecial
09/24/2020Energy Code Compliance InspectionsAN MAprogress
09/24/2020HVAC insulation and sealing AN MAenergy_progress
10/08/2019FinalAN MAprogress
▾Documents — 93 on file (BIS + DOB NOW)
▸Plans & Drawings4
▸DOB NOWPlans/Sketch - Plumbing3
08/27/2026Q00242757-I1Request digital key ↗
08/15/2026Q00242757-P2Request digital key ↗
08/15/2026Q00242757-P1Request digital key ↗
▸DOB NOWPlans/Sketch - Construction Fence1
08/28/2026Q00242756-I1Request digital key ↗
▸Applications & Permits20
▸BISPLAN / WORK APPROVAL APPLICATION16
03/01/2022421906968Open ↗
02/28/2022421906968Open ↗
06/10/2021421906968Open ↗
Showing 3 of 16 on file for this type
▸BISPARTIAL DEMO: 10-DAY NOTICE (FOR AL/EW-OT PERMITS)1
09/09/2020421906968Open ↗
▸BISPARTIAL DEMO PLAN & DS1 (FOR AL/EW-OT PERMITS)1
09/09/2020421906968Open ↗
▸BISCERTIFICATE OF OCCUPANCY: APPLICATION1
06/11/2021421906968Open ↗
▸BISWORK PERMIT APPLICATION1
09/09/2020421906968Open ↗
▸Zoning, Tax Lot & Property Records4
▸BISZONING DIAGRAM2
10/01/2020421906968Open ↗
01/09/2020421906968Open ↗
▸BISTAX LOT: TENTATIVE LOT NUMBER ISSUED1
09/24/2020421757245Open ↗
▸BISVERIFY TAX LOT1
01/14/2022421906968Open ↗
▸Seals & Professional Certifications24
▸DOB NOWSpecial Inspector Seal & Signature9
08/28/2026Q00242757-P2Open ↗
08/28/2026Q00242757-P2Open ↗
08/28/2026Q00242757-P2Open ↗
Showing 3 of 9 on file for this type
▸DOB NOWProgress Inspector Seal & Signature7
08/28/2026Q00242757-P2Open ↗
08/28/2026Q00242757-P2Open ↗
08/26/2026Q00242757-P1Open ↗
Showing 3 of 7 on file for this type
▸DOB NOWDPL-1: Design Professional Seal & Signature4
08/27/2026Q00242757-I1Open ↗
08/27/2026Q00242757-P2Open ↗
08/27/2026Q00242757-P1Open ↗
Showing 3 of 4 on file for this type
▸BISTECHNICAL REPORT: RESPONSIBILITY/CERTIFICATION2
01/16/2020421906968Open ↗
11/14/2019421906968Open ↗
▸BISPROFESSIONAL CERTIFICATION STATEMENT1
11/14/2019421906968Open ↗
▸BISPROFESSIONAL CERTIFIED CHECKLIST1
11/14/2019421906968Open ↗
▸Trade Schedules & Equipment2
▸BISDETECTOR:SMOKE-CERT. OF INSTALLATION1
01/14/2022421906968Open ↗
▸BISDETECTOR:CARBON MONOXIDE-CERT.OF INSTALL1
01/14/2022421906968Open ↗
▸Safety & Tenant Protection1
▸BISSTREET TREE CHECKLIST1
11/14/2019421906968Open ↗
▸Environmental & Asbestos4
▸DOB NOWDEP ACP-5: Asbestos Assessment Report3
08/27/2026Q00242757-P2Open ↗
08/27/2026Q00242757-P1Open ↗
08/27/2026Q00242757-I1Open ↗
▸BISASBESTOS: CERTIFICATION (DEP ACP5)1
11/14/2019421906968Open ↗
▸Energy Compliance3
▸BISTECHNICAL REPORT: ENERGY CODE - RESPONSIBILITY1
01/14/2022421906968Open ↗
▸BISAS-BUILT ENERGY ANALYSIS (EN2)1
01/14/2022421906968Open ↗
▸BISTECHNICAL REPORT: ENERGY CODE PROGRESS INSPS1
11/14/2019421906968Open ↗
▸Inspections & Test Reports4
▸BISTECHNICAL REPORT: RESPONSIBILITY3
01/14/2022421906968Open ↗
01/14/2022421906968Open ↗
09/09/2020421906968Open ↗
▸BISTECHNICAL REPORT: SOIL INSPECTION1
01/16/2020421906968Open ↗
▸Approvals, Objections & Sign-offs13
▸BISLETTERS - SUPPORTING DOCUMENTATION9
03/01/2022421906968Open ↗
03/01/2022421906968Open ↗
06/04/2021421906968Open ↗
Showing 3 of 9 on file for this type
▸BISSCHEDULE A - OCCUPANCY / USE3
02/28/2022421906968Open ↗
09/10/2020421906968Open ↗
11/14/2019421906968Open ↗
▸BISSUSTAINABLE ROOF ZONE FORM (SIGNOFF)1
11/23/2021421906968Open ↗
▸Cost, Insurance & Ownership3
▸BISCOST AFFIDAVIT (FINAL): PW31
01/14/2022421906968Open ↗
▸BISDEPT OF FINANCE VERIFICATION1
01/16/2020421906968Open ↗
▸BISCOST AFFIDAVIT1
11/14/2019421906968Open ↗
▸Filing & Intake Forms6
▸BISADDITIONAL INFORMATION4
06/10/2021421906968Open ↗
12/07/2020421906968Open ↗
11/04/2020421906968Open ↗
Showing 3 of 4 on file for this type
▸BISEFILING COVER SHEET2
03/07/2020421757245Open ↗
11/15/2019421906968Open ↗
▸Other Documents5
▸BISPLOT DIAGRAM2
06/04/2021421906968Open ↗
11/14/2019421906968Open ↗
▸BISPD1 PLOT DIAGRAM1
09/25/2020421757245Open ↗
▸BISRECORDS MGMT FEE PAYMENT RECEIPT1
09/24/2020421757245Open ↗
▸BISDIGITAL TAX MAP1
09/25/2020421757245Open ↗