← Back
Two family frame
45-44 KISSENA BOULEVARD
QUEENS · East Flushing · BIN 4116447
💬 Discuss this project
1930Year Built
2.5Stories
B2Building Class
R3-2Zoning
2,805 sfGross Floor Area
2Units
0 Open Violations
Two family frame · Owner of record: CLBK PROEPRTY LLC · 4,000 sf lot · 0.7 FAR built · Flood zone X
Locations of Work
ArchitectureMechanicalPlumbingGeneral
Floor 25p · 3 filings · 20 docs
Floor 17p · 2 filings · 20 docs
Cellar8p · 2 filings · 20 docs
Site & exterior2p · 1 filing · 11 docs
▾Sales History (ACRIS)
DatePriceUnitSeller → Buyer$/sf
11/29/2022$1.4M—Private party → CLBK PROEPRTY LLC$481/sf building
▾Design Consultants (Architect / Engineer of Record)
FirmFilingsMost Recent
AN SHEN MA ARCHITECT405/08/2024
▾Contractors (License-Anchored)
FirmTradeRolesMost Recent
LXC CONSTRUCTION INCGeneral Contractor407/08/2026
PRIMROSE SERVICE INCGeneral Contractor303/21/2026
RRP PLUMBING CORPPlumbing107/08/2026
▾Special Inspection Agencies
AgencyLicense #FilingsMost Recent
AN SHEN MA ARCHITECT2968405/08/2024
Building Lifecycle
All (54)Filed (4)Permit Issued (4)Signed Off (2)Violation (1)Inspection (7)Objection (6)Special Inspection (30)
05/31/2024
Signed off — Alteration
TO RENOVATE EXISTING 3 STORY 2 FAMILY DWELLING. WORK TO INCLUDE THE INSTALLATION & REMOVAL OF WALLS & FENESTRATION. ALSO TO INSTALL MECHANICAL EQUIPMENT. NO CHANGE OF USE, EGRESS OR OCCUPANCY.
Q00827340-I1
05/30/2024
Signed off — Alteration
TO INSTALL, RELOCATE, REPLACE OR REMOVE PLUMBING FIXTURES IN EXISTING 3 STORY 2 FAMILY DWELLING. FILED IN CONJUNCTION W/ HOUSE ALT #Q00827340. NO CHANGE OF USE, EGRESS OR OCCUPANCY.
Q00827724-I1
05/29/2024
Permit issued — Mechanical Systems
Q00827340-I1-MS
05/29/2024
Inspection — Pass-Final General Construction Non-Directive 14
Pass
View inspection ↗
05/21/2024
Permit issued — Mechanical Systems
Q00827340-I1-GC
05/17/2024
Special inspection requirement — HVAC-R and service water heating equipment
AN MA
05/17/2024
Special inspection requirement — Mechanical Systems
AN MA
05/17/2024
Special inspection requirement — Heating Systems
AN MA
05/17/2024
Special inspection requirement — Structural Stability – Alterations of existing buildings
AN MA
05/17/2024
Special inspection requirement — Fire-Resistant Penetrations and Joints
AN MA
05/17/2024
Special inspection requirement — Final
AN MA
05/17/2024
Special inspection requirement — Fire-Resistance Rated Construction
AN MA
05/17/2024
Special inspection requirement — Energy Code Compliance Inspections
AN MA
05/17/2024
Special inspection requirement — Air barrier - visual inspection
AN MA
05/17/2024
Special inspection requirement — Fenestration air leakage
AN MA
05/17/2024
Special inspection requirement — Metering
AN MA
05/17/2024
Special inspection requirement — Interior lighting power
AN MA
05/17/2024
Special inspection requirement — Fenestration and door U-factor and product ratings
AN MA
05/17/2024
Special inspection requirement — Fenestration areas
AN MA
05/17/2024
Special inspection requirement — HVAC-R and service water heating system controls
AN MA
05/17/2024
Special inspection requirement — Insulation placement and R values
AN MA
05/17/2024
Special inspection requirement — Permanent certificate
AN MA
05/17/2024
Special inspection requirement — Ventilation and air distribution system
AN MA
05/08/2024
Filed — Alteration
TO RENOVATE EXISTING 3 STORY 2 FAMILY DWELLING. WORK TO INCLUDE THE INSTALLATION & REMOVAL OF WALLS & FENESTRATION. ALSO TO INSTALL MECHANICAL EQUIPMENT. NO CHANGE OF USE, EGRESS OR OCCUPANCY.
Q00827340-P1
05/01/2024
Special inspection requirement — Fenestration areas
AN MA
05/01/2024
Special inspection requirement — HVAC-R and service water heating system controls
AN MA
05/01/2024
Special inspection requirement — Permanent certificate
AN MA
05/01/2024
Special inspection requirement — Air barrier - visual inspection
AN MA
05/01/2024
Special inspection requirement — Interior lighting power
AN MA
05/01/2024
Special inspection requirement — Fenestration and door U-factor and product ratings
AN MA
05/01/2024
Special inspection requirement — Fenestration air leakage
AN MA
05/01/2024
Special inspection requirement — Metering
AN MA
05/01/2024
Special inspection requirement — Ventilation and air distribution system
AN MA
05/01/2024
Special inspection requirement — Fire-Resistant Penetrations and Joints
AN MA
05/01/2024
Special inspection requirement — Heating Systems
AN MA
05/01/2024
Special inspection requirement — Mechanical Systems
AN MA
04/26/2024
Inspection — Fail-Final General Construction Non-Directive 14
Fail
View inspection ↗
04/12/2024
Inspection — Fail-Final General Construction Non-Directive 14
Fail
View inspection ↗
03/01/2024
Inspection — Pass-Final PL - Up to 3 Requested Floors
Pass
View inspection ↗
02/21/2024
Inspection — Fail-Final PL - Up to 3 Requested Floors
Fail
View inspection ↗
09/21/2023
Inspection — Pass-Final PL - Up to 3 Requested Floors
Pass
View inspection ↗
08/22/2023
Filed — Alteration
TO INSTALL, RELOCATE, REPLACE OR REMOVE PLUMBING FIXTURES IN EXISTING 3 STORY 2 FAMILY DWELLING. FILED IN CONJUNCTION W/ HOUSE ALT #Q00827340. NO CHANGE OF USE, EGRESS OR OCCUPANCY.
Q00827724-P1
08/15/2023
Inspection — Pass-Final PL - Up to 3 Requested Floors
Pass
View inspection ↗
06/23/2023
Permit issued — Plumbing
Q00827724-I1-PL
06/20/2023
Filed — Alteration
TO INSTALL, RELOCATE, REPLACE OR REMOVE PLUMBING FIXTURES IN EXISTING 3 STORY 2 FAMILY DWELLING. FILED IN CONJUNCTION W/ HOUSE ALT #Q00827340. NO CHANGE OF USE, EGRESS OR OCCUPANCY.
Q00827724-I1
05/03/2023
Permit issued — Mechanical Systems
Q00827340-I1-GC
03/28/2023
Objection raised — Mechanical
03/28/2023
Objection resolved — Addressed
03/28/2023
Objection raised — Other
03/28/2023
Objection resolved — Addressed
03/28/2023
Objection raised — Zoning
03/28/2023
Objection resolved — Addressed
03/21/2023
Filed — Alteration
TO RENOVATE EXISTING 3 STORY 2 FAMILY DWELLING. WORK TO INCLUDE THE INSTALLATION & REMOVAL OF WALLS & FENESTRATION. ALSO TO INSTALL MECHANICAL EQUIPMENT. NO CHANGE OF USE, EGRESS OR OCCUPANCY.
Q00827340-I1
11/16/2002
Violation issued (ECB, closed)
Construction
Permit / Filing Register
SourceWork TypeStatusApplicantIssued
DOB NOWMechanical SystemsSigned-offLXC CONSTRUCTION INC05/29/2024
DOB NOWMechanical SystemsSigned-offLXC CONSTRUCTION INC05/21/2024
DOB NOWPlumbingSigned-offRRP PLUMBING CORP06/23/2023
DOB NOWMechanical SystemsSigned-offPRIMROSE SERVICE INC05/03/2023
2 projects · most recent 03/27/2024
General Wiring
FiledStatusContractorScope
03/27/2024CompleteJUN SAFETY ELECTRICAL INCGeneral Wiring
11/01/2023CompleteJUN SAFETY ELECTRICAL INCGeneral Wiring
▾Field Inspections (DOB CAP) — 7
DateTypeResultReport
05/29/2024Pass-Final General Construction Non-Directive 14PassView ↗
04/26/2024Fail-Final General Construction Non-Directive 14FailView ↗
04/12/2024Fail-Final General Construction Non-Directive 14FailView ↗
03/01/2024Pass-Final PL - Up to 3 Requested FloorsPassView ↗
02/21/2024Fail-Final PL - Up to 3 Requested FloorsFailView ↗
09/21/2023Pass-Final PL - Up to 3 Requested FloorsPassView ↗
08/15/2023Pass-Final PL - Up to 3 Requested FloorsPassView ↗
▾Special Inspection Requirements (DOB NOW) — 42
DateRequirementInspectorRole
05/17/2024HVAC-R and service water heating equipmentAN MAenergy_progress
05/17/2024Mechanical SystemsAN MAspecial
05/17/2024Heating SystemsAN MAspecial
05/17/2024Structural Stability – Alterations of existing buildingsAN MAspecial
05/17/2024Fire-Resistant Penetrations and JointsAN MAspecial
05/17/2024FinalAN MAprogress
05/17/2024Fire-Resistance Rated ConstructionAN MAprogress
05/17/2024Energy Code Compliance InspectionsAN MAprogress
05/17/2024Air barrier - visual inspectionAN MAenergy_progress
05/17/2024Fenestration air leakageAN MAenergy_progress
05/17/2024MeteringAN MAenergy_progress
05/17/2024Interior lighting powerAN MAenergy_progress
05/17/2024Fenestration and door U-factor and product ratingsAN MAenergy_progress
05/17/2024Fenestration areasAN MAenergy_progress
05/17/2024HVAC-R and service water heating system controlsAN MAenergy_progress
05/17/2024Insulation placement and R valuesAN MAenergy_progress
05/17/2024Permanent certificateAN MAenergy_progress
05/17/2024Ventilation and air distribution systemAN MAenergy_progress
05/01/2024Fenestration areasAN MAenergy_progress
05/01/2024HVAC-R and service water heating system controlsAN MAenergy_progress
05/01/2024Permanent certificateAN MAenergy_progress
05/01/2024Air barrier - visual inspectionAN MAenergy_progress
05/01/2024Interior lighting powerAN MAenergy_progress
05/01/2024Fenestration and door U-factor and product ratingsAN MAenergy_progress
05/01/2024Fenestration air leakageAN MAenergy_progress
Latest 25 of 42.
▾Documents — 26 on file (BIS + DOB NOW)
▸Plans & Drawings4
▸DOB NOWPlans/Sketch4
08/25/2026Q00827340-P1Request digital key ↗
08/24/2026Q00827724-P1Request digital key ↗
08/24/2026Q00827724-I1Request digital key ↗
Showing 3 of 4 on file for this type
▸Seals & Professional Certifications18
▸DOB NOWProgress Inspector Seal & Signature10
08/29/2026Q00827340-I1Open ↗
08/29/2026Q00827340-I1Open ↗
08/29/2026Q00827340-I1Open ↗
Showing 3 of 10 on file for this type
▸DOB NOWDPL-1: Design Professional Seal & Signature4
08/25/2026Q00827340-I1Open ↗
08/24/2026Q00827724-P1Open ↗
08/24/2026Q00827724-I1Open ↗
Showing 3 of 4 on file for this type
▸DOB NOWSpecial Inspector Seal & Signature4
08/29/2026Q00827340-I1Open ↗
08/29/2026Q00827724-P1Open ↗
08/28/2026Q00827340-P1Open ↗
Showing 3 of 4 on file for this type
▸Environmental & Asbestos2
▸DOB NOWDEP ACP-20/ACP-21: Asbestos Project Conditional Completion Form/Asbestos Project Completion Form2
08/24/2026Q00827724-I1Open ↗
08/13/2026Q00827340-I1Open ↗
▸Other Documents2
▸DOB NOWLocal Law 92/94 of 2019 Sustainable Roof Zone2
08/15/2026Q00827340-I1Open ↗
08/13/2026Q00827340-P1Open ↗