← Back
Primarily 2 family with 1 store or office
45-73 PARSONS BOULEVARD
QUEENS · BIN 4623798
💬 Discuss this project
2022Year Built
3Stories
S2Building Class
R3XZoning
2,981 sfGross Floor Area
3Units
0 Open ViolationsFDNY Report ↗
Primarily 2 family with 1 store or office · 3,891 sf lot · 0.77 FAR built · Flood zone X
Locations of Work
ArchitectureStructural
Floor 319p · 1 filing · 20 docs
Floor 221p · 1 filing · 20 docs
Floor 120p · 1 filing · 20 docs
Cellar20p · 1 filing · 20 docs
▾Owner History (Filing Record)
Companies and organizations named on filings. Individual owners are not shown.
OwnerFilingsMost Recent
ZR WHITESTONE INC YI CHEN103/22/2026
▾Design Consultants (Architect / Engineer of Record)
FirmFilingsMost Recent
ROBERT LIN1602/06/2026
▾Filing Representatives (Expediters)
RepresentativeFilingsMost Recent
LOXTON3003/21/2026
▾Contractors (License-Anchored)
FirmTradeRolesMost Recent
ZR WHITESTONE INCGeneral Contractor1207/08/2026
HY DESIGN & DEVELOPMENT LLC.General Contractor407/08/2026
LOXTON INCGeneral Contractor303/21/2026
CASE PLUMBING LLCFire Protection207/08/2026
KJK ELECTRIC INCElectrical103/22/2026
CATMAN PLUMBING INCPlumbing107/08/2026
▾Special Inspection Agencies
AgencyLicense #FilingsMost Recent
A & T DESIGN GROUP LLC10882302/06/2026
Building Lifecycle
All (80)Filed (15)Permit Issued (12)Signed Off (6)Violation (1)Inspection (8)Objection (8)Special Inspection (30)
04/23/2026
Signed off — New Building
PROPOSED THREE STORY W/ CELLAR, TWO FAMILY W/ COMMUNITY FACILITIES BUILDING.OBTAIN NEW CERTIFICATE OF OCCUPANCY.
Q00503501-I1
04/01/2026
Inspection — Pass-Final CND-Occupancy Inspection
Pass
View inspection ↗
03/25/2026
Inspection — Pass-Final CND-Occupancy Inspection
Pass
View inspection ↗
03/06/2026
Special inspection requirement — Lighting controls
ROBERT LIN
03/06/2026
Special inspection requirement — Fire-Resistant Penetrations and Joints
ROBERT LIN
03/06/2026
Special inspection requirement — Air barrier - visual inspection
ROBERT LIN
03/06/2026
Special inspection requirement — Fenestration and door U-factor and product ratings
ROBERT LIN
03/06/2026
Special inspection requirement — Concrete - Cast-In-Place
ROBERT LIN
03/06/2026
Special inspection requirement — Excavations - Sheeting, Shoring, and Bracing
ROBERT LIN
03/06/2026
Special inspection requirement — Exterior lighting power
ROBERT LIN
03/06/2026
Special inspection requirement — Air barrier — testing
ROBERT LIN
03/06/2026
Special inspection requirement — Interior lighting power
ROBERT LIN
03/06/2026
Special inspection requirement — Fenestration air leakage
ROBERT LIN
03/06/2026
Special inspection requirement — HVAC-R and service water piping design and insulation
ROBERT LIN
03/06/2026
Special inspection requirement — Private On-Site Storm Water Disposal Systems-, and Detention Facilities, Installation
ROBERT LIN
03/06/2026
Special inspection requirement — Masonry
ROBERT LIN
03/06/2026
Special inspection requirement — Maintenance information
ROBERT LIN
03/06/2026
Special inspection requirement — Fire-Resistance Rated Construction
ROBERT LIN
03/06/2026
Special inspection requirement — Energy Code Compliance Inspections
ROBERT LIN
03/06/2026
Special inspection requirement — Insulation placement and R values
ROBERT LIN
03/06/2026
Special inspection requirement — Metering
ROBERT LIN
03/06/2026
Special inspection requirement — Electric vehicle service equipment requirements
ROBERT LIN
03/06/2026
Special inspection requirement — Fenestration areas
ROBERT LIN
03/06/2026
Special inspection requirement — Permanent certificate
ROBERT LIN
03/06/2026
Special inspection requirement — Protection of exposed foundation insulation
ROBERT LIN
03/06/2026
Special inspection requirement — Sprayed fire-resistant materials
ROBERT LIN
02/06/2026
Filed — New Building
PROPOSED THREE STORY W/ CELLAR, TWO FAMILY W/ COMMUNITY FACILITIES BUILDING.OBTAIN NEW CERTIFICATE OF OCCUPANCY.
Q00503501-A4
02/06/2026
Special inspection requirement — Energy Code Compliance Inspections
ROBERT LIN
02/06/2026
Special inspection requirement — Sprayed fire-resistant materials
ROBERT LIN
02/06/2026
Special inspection requirement — Private On-Site Storm Water Disposal Systems-, and Detention Facilities, Installation
ROBERT LIN
02/06/2026
Special inspection requirement — Masonry
ROBERT LIN
02/06/2026
Special inspection requirement — Fire-Resistant Penetrations and Joints
ROBERT LIN
02/06/2026
Special inspection requirement — Excavations - Sheeting, Shoring, and Bracing
ROBERT LIN
02/06/2026
Special inspection requirement — Concrete - Cast-In-Place
ROBERT LIN
01/23/2026
Objection resolved — Addressed
01/21/2026
Objection raised — Other
12/17/2025
Objection resolved — Addressed
12/12/2025
Objection raised — Other
11/20/2025
Objection resolved — Addressed
11/19/2025
Objection raised — Other
10/29/2025
Filed — New Building
PROPOSED THREE STORY W/ CELLAR, TWO FAMILY W/ COMMUNITY FACILITIES BUILDING.OBTAIN NEW CERTIFICATE OF OCCUPANCY.
Q00503501-A3
10/09/2025
Objection resolved — Addressed
10/08/2025
Objection raised — Scope
09/22/2025
Filed — New Building
PROPOSED THREE STORY W/ CELLAR, TWO FAMILY W/ COMMUNITY FACILITIES BUILDING.OBTAIN NEW CERTIFICATE OF OCCUPANCY.
Q00503501-A2
08/15/2025
Filed — New Building
PROPOSED THREE STORY W/ CELLAR, TWO FAMILY W/ COMMUNITY FACILITIES BUILDING.OBTAIN NEW CERTIFICATE OF OCCUPANCY.
Q00503501-P9
07/10/2024
Filed — New Building
PROPOSED THREE STORY W/ CELLAR, TWO FAMILY W/ COMMUNITY FACILITIES BUILDING.OBTAIN NEW CERTIFICATE OF OCCUPANCY.
Q00503501-P8
05/23/2024
Filed — New Building
PROPOSED THREE STORY W/ CELLAR, TWO FAMILY W/ COMMUNITY FACILITIES BUILDING.OBTAIN NEW CERTIFICATE OF OCCUPANCY.
Q00503501-P7
05/20/2024
Signed off — New Building
PROPOSED THREE STORY W/ CELLAR, TWO FAMILY W/ COMMUNITY FACILITIES BUILDING.OBTAIN NEW CERTIFICATE OF OCCUPANCY.
Q00503501-S4
05/20/2024
Signed off — New Building
PROPOSED THREE STORY W/ CELLAR, TWO FAMILY W/ COMMUNITY FACILITIES BUILDING.OBTAIN NEW CERTIFICATE OF OCCUPANCY.
Q00503501-S3
05/15/2024
Signed off — New Building
PROPOSED THREE STORY W/ CELLAR, TWO FAMILY W/ COMMUNITY FACILITIES BUILDING.OBTAIN NEW CERTIFICATE OF OCCUPANCY.
Q00503501-S5
04/11/2024
Signed off — Alteration
THIS JOB IS FILED FOR CONSTRUCTION FENCE FOR NB WORK AT 45-73 NORTHERN BLVD, QUEENS, NY 11355. NB JOB#Q00503501-I1
Q00760926-I1
03/28/2024
Signed off — New Building
PROPOSED THREE STORY W/ CELLAR, TWO FAMILY W/ COMMUNITY FACILITIES BUILDING.OBTAIN NEW CERTIFICATE OF OCCUPANCY.
Q00503501-S1
03/27/2024
Inspection — Pass-Final Curb Cut Non-Directive 14
Pass
View inspection ↗
03/06/2024
Inspection — Certified Sprinkler-SP-Fixtures-Finish
Certified
View inspection ↗
02/21/2024
Filed — New Building
PROPOSED THREE STORY W/ CELLAR, TWO FAMILY W/ COMMUNITY FACILITIES BUILDING.OBTAIN NEW CERTIFICATE OF OCCUPANCY.
Q00503501-P6
01/31/2024
Inspection — Pass-Final CND-Occupancy Inspection
Pass
View inspection ↗
01/30/2024
Inspection — Certified Sprinkler-SP-Piping Dry/Wet-Hydrostatic Test
Certified
View inspection ↗
01/24/2024
Permit issued — General Construction
Q00503501-I1-GC
01/19/2024
Permit issued — Plumbing
Q00503501-S5-EW-SP
01/12/2024
Permit issued — Curb Cut
Q00503501-S1-CC
Latest 60 of 80 events.
Permit / Filing Register
SourceWork TypeStatusApplicantIssued
DOB NOWGeneral ConstructionPermit IssuedFANG YE01/24/2024
DOB NOWPlumbingSigned-offS & L PLUMBING INC01/19/2024
DOB NOWCurb CutSigned-offFANG YE01/12/2024
DOB NOWSprinklersSigned-offS & L PLUMBING INC03/28/2023
DOB NOWSprinklersSigned-offCATMAN PLUMBING INC03/23/2023
DOB NOWFoundationSigned-offZR WHITESTONE INC01/02/2023
DOB NOWConstruction FenceSigned-offZR WHITESTONE INC12/29/2022
DOB NOWSupport of ExcavationSigned-offZR WHITESTONE INC12/29/2022
DOB NOWSupport of ExcavationSigned-offZR WHITESTONE INC07/19/2022
DOB NOWConstruction FenceSigned-offZR WHITESTONE INC06/22/2022
DOB NOWStructuralSigned-offZR WHITESTONE INC06/18/2022
DOB NOWGeneral ConstructionSigned-offLOXTON INC05/31/2022
1 project · most recent 02/06/2026
Sprinkler System
FiledStatusContractorScope
02/06/2026Signed-offCASE PLUMBING LLCSprinkler System
1 project · most recent 02/06/2026
Gas Storm Water/Sanitary
FiledStatusContractorScope
02/06/2026Signed-offCATMAN PLUMBING INCGas, Storm, Water/Sanitary
1 project · most recent 07/24/2023
General Wiring
FiledStatusContractorScope
07/24/2023CompleteKJK ELECTRIC INCGeneral Wiring
▾Field Inspections (DOB CAP) — 8
DateTypeResultReport
04/01/2026Pass-Final CND-Occupancy InspectionPassView ↗
03/25/2026Pass-Final CND-Occupancy InspectionPassView ↗
03/27/2024Pass-Final Curb Cut Non-Directive 14PassView ↗
03/06/2024Certified Sprinkler-SP-Fixtures-FinishCertifiedView ↗
01/31/2024Pass-Final CND-Occupancy InspectionPassView ↗
01/30/2024Certified Sprinkler-SP-Piping Dry/Wet-Hydrostatic TestCertifiedView ↗
04/26/2023Certified Water and Sanitary-WS-Sanitary Piping-RoughingCertifiedView ↗
04/26/2023Certified Water and Sanitary-WS-Sanitary Piping-UndergroundCertifiedView ↗
▾Special Inspection Requirements (DOB NOW) — 150
DateRequirementInspectorRole
03/06/2026Maintenance informationROBERT LINenergy_progress
03/06/2026HVAC-R and service water piping design and insulationROBERT LINenergy_progress
03/06/2026Lighting controlsROBERT LINenergy_progress
03/06/2026Fenestration and door U-factor and product ratingsROBERT LINenergy_progress
03/06/2026Fenestration air leakageROBERT LINenergy_progress
03/06/2026Protection of exposed foundation insulationROBERT LINenergy_progress
03/06/2026Permanent certificateROBERT LINenergy_progress
03/06/2026Interior lighting powerROBERT LINenergy_progress
03/06/2026Fenestration areasROBERT LINenergy_progress
03/06/2026Electric vehicle service equipment requirementsROBERT LINenergy_progress
03/06/2026Air barrier - visual inspectionROBERT LINenergy_progress
03/06/2026Air barrier — testing ROBERT LINenergy_progress
03/06/2026MeteringROBERT LINenergy_progress
03/06/2026Insulation placement and R valuesROBERT LINenergy_progress
03/06/2026Exterior lighting powerROBERT LINenergy_progress
03/06/2026Energy Code Compliance InspectionsROBERT LINprogress
03/06/2026Fire-Resistance Rated ConstructionROBERT LINprogress
03/06/2026Fire-Resistant Penetrations and JointsROBERT LINspecial
03/06/2026Concrete - Cast-In-PlaceROBERT LINspecial
03/06/2026Private On-Site Storm Water Disposal Systems-, and Detention Facilities, InstallationROBERT LINspecial
03/06/2026MasonryROBERT LINspecial
03/06/2026Sprayed fire-resistant materialsROBERT LINspecial
03/06/2026Excavations - Sheeting, Shoring, and BracingROBERT LINspecial
02/06/2026Concrete - Cast-In-PlaceROBERT LINspecial
02/06/2026Excavations - Sheeting, Shoring, and BracingROBERT LINspecial
Latest 25 of 150.
▾Documents — 347 on file (BIS + DOB NOW)
▸Plans & Drawings16
▸DOB NOWPlans/Sketch16
08/26/2026Q00760926-I1Request digital key ↗
Showing 1 of 16 on file for this type
▸Applications & Permits2
▸BISPLAN / WORK APPROVAL APPLICATION1
11/20/2021440689916Open ↗
▸BISBPP-5 - Authorization to the Department of Transportation1
11/20/2021440689916Open ↗
▸Zoning, Tax Lot & Property Records19
▸DOB NOWZD1: DOB Zoning Diagram9
On file, but not among the 200 most recently loaded documents for this source.
Showing 0 of 9 on file for this type
▸DOB NOWZoning Exhibit form (1-5)9
On file, but not among the 200 most recently loaded documents for this source.
Showing 0 of 9 on file for this type
▸DOB NOWHouse Number Verification: TOPO Stamp1
On file, but not among the 200 most recently loaded documents for this source.
Showing 0 of 1 on file for this type
▸Seals & Professional Certifications239
▸DOB NOWProgress Inspector Seal & Signature161
09/27/2026Q00503501-P2Open ↗
09/27/2026Q00503501-P2Open ↗
09/19/2026Q00503501-P1Open ↗
Showing 3 of 161 on file for this type
▸DOB NOWSpecial Inspector Seal & Signature60
09/27/2026Q00503501-P2Open ↗
09/19/2026Q00503501-P1Open ↗
09/19/2026Q00503501-P1Open ↗
Showing 3 of 60 on file for this type
▸DOB NOWDPL-1: Design Professional Seal & Signature16
On file, but not among the 200 most recently loaded documents for this source.
Showing 0 of 16 on file for this type
▸BISTECHNICAL REPORT STATEMENT OF RESPONSIBILITY1
11/20/2021440689916Open ↗
▸BISAPPLICANT OWNER SIGNATURE1
11/20/2021440689916Open ↗
▸Trade Schedules & Equipment9
▸DOB NOWDEP: Sewer Certification (Sanitary/Storm)9
On file, but not among the 200 most recently loaded documents for this source.
Showing 0 of 9 on file for this type
▸Safety & Tenant Protection17
▸DOB NOWStreet Tree Checklist9
On file, but not among the 200 most recently loaded documents for this source.
Showing 0 of 9 on file for this type
▸BISSTREET TREE CHECKLIST2
09/16/2022440689916Open ↗
11/20/2021440689916Open ↗
▸DOB NOWStreet Tree Sign Off2
On file, but not among the 200 most recently loaded documents for this source.
Showing 0 of 2 on file for this type
▸DOB NOWParks Department Acknowledgment Letter for Street Trees Plan2
On file, but not among the 200 most recently loaded documents for this source.
Showing 0 of 2 on file for this type
▸BISSTREET TREE SIGNOFF1
08/07/2024440689916Open ↗
▸DOB NOWStreet Trees Site Plan1
On file, but not among the 200 most recently loaded documents for this source.
Showing 0 of 1 on file for this type
▸Energy Compliance2
▸DOB NOWEN2: As Built Energy Analysis.2
On file, but not among the 200 most recently loaded documents for this source.
Showing 0 of 2 on file for this type
▸Approvals, Objections & Sign-offs2
▸BISDOT APPROVAL FOR OPPOSITE CORNER PED-RAMP & APEX CORNER PEDRAMP1
05/19/2025440689916Open ↗
▸BISDOB APPROVAL FOR NEW CC1
09/16/2022440689916Open ↗
▸Filing & Intake Forms2
▸BISBPP: CHECKLIST IN LIEU OF PLANS-ALT31
11/20/2021440689916Open ↗
▸BISEFILING JOB APPLICATION COVER SHEET1
11/20/2021440689916Open ↗
▸Other Documents39
▸BISBPP - SUPPORTING DOCUMENTATION11
05/19/2025440689916Open ↗
05/19/2025440689916Open ↗
05/19/2025440689916Open ↗
Showing 3 of 11 on file for this type
▸DOB NOWLocal Law 92/94 of 2019 Sustainable Roof Zone11
On file, but not among the 200 most recently loaded documents for this source.
Showing 0 of 11 on file for this type
▸DOB NOWSite Survey: Initial10
On file, but not among the 200 most recently loaded documents for this source.
Showing 0 of 10 on file for this type
▸DOB NOWAdjoining Owners Notification2
On file, but not among the 200 most recently loaded documents for this source.
Showing 0 of 2 on file for this type
▸BISBPP-TA: RELOCATE BUS STOP1
11/07/2022440689916Open ↗
▸BISBPP-PARKS: PLANT NEW TREE1
05/21/2025440689916Open ↗
▸BISRP 6021
09/16/2022440689916Open ↗
▸DOB NOWProperty Ownership Certification1
On file, but not among the 200 most recently loaded documents for this source.
Showing 0 of 1 on file for this type
▸DOB NOWFinal Survey1
On file, but not among the 200 most recently loaded documents for this source.
Showing 0 of 1 on file for this type