← Back
STATEN ISLAND
45 CLEVELAND PLACE
STATEN ISLAND · BIN 5176888
💬 Discuss this project
—Year Built
—Stories
—Building Class
—Zoning
—Gross Floor Area
—Units
0 Open ViolationsFDNY Report ↗
Flood zone X
Locations of Work
StructuralElectricalMechanicalPlumbingFire Protection
Permit Issued — active, not yet Signed-off
Roof6p · 1 filing · 20 docs
Bulkhead1p · 1 filing · 20 docs
Floor 53p · 1 filing · 20 docs
Floor 43p · 1 filing · 20 docs
Floor 34p · 1 filing · 20 docs
Floor 23p · 1 filing · 20 docs
Floor 1Under Construction17p · 2 filings · 20 docs
Cellar6p · 1 filing · 20 docs
3 jobs · most recent 04/07/2026
Ventilation Systems Generators Heating and Air Conditioning Systems Refrigeration Systems
FiledStatusContractorScopeMake / Model / Capacity
04/07/2026——Generators, Heating and Air Conditioning Systems, Refrigeration Systems, Ventilation Systems
Heat / Cool
Lg ARUM036GSS5 69,000 BTU · Vrf Outdoor ×8
ARNU123SJA4 12,300 BTU · Vrf Indoor ×5
ARNU243SKA4 24,200 BTU · Vrf Indoor ×6
ARNU363SVA4 35,500 BTU · Vrf Indoor ×3
Ventilation
Greenheck FJ1-9-BI 100 CFM · Exhaust Fan ×4
USF-13-B7 1,400 CFM · Makeup Air ×4
G-100HP-A 300 CFM ×2
CUBE-100HP 250 CFM · Exhaust Fan ×1
CUE-180-B 2,950 CFM · Exhaust Fan ×1
G-097-A 200 CFM · Exhaust Fan ×2
G-099-A 650 CFM · Exhaust Fan ×1
G-100-A 900 CFM · Exhaust Fan ×1
G-120-A 975 CFM · Exhaust Fan ×1
G-160-A 3,650 CFM · Exhaust Fan ×1
USF-15-B7 2,200 CFM · Exhaust Fan ×1
USF-22-B7 5,000 CFM · Exhaust Fan ×1
VK-H-13-8 13,000 CFM · Exhaust Fan ×4
CUE-140-A 2,250 CFM · Exhaust Fan ×1
G-098-A 450 CFM · Exhaust Fan ×1
GB-100HP 500 CFM · Exhaust Fan ×1
USF-44-B4 28,000 CFM · Exhaust Fan ×1
Annexaire ERP-E-16-EW07-HE-D-SW 16,500 CFM · Rooftop Unit ×2
ERP-E-20-EW09-HE-D-SW 21,000 CFM · Rooftop Unit ×2
AHU-E-12-HE-D 14,000 CFM · Rooftop Unit ×1
ERP-E-04-EW02-HE-D-SW 3,800 CFM · Rooftop Unit ×1
ERP-E-12-EW04-HE-D-SW 12,000 CFM · Rooftop Unit ×1
ERP-E-12-EW05-HE-D 13,000 CFM · Rooftop Unit ×1
ERP-E-25-EW16-HE-D-SW 26,000 CFM · Rooftop Unit ×1
Refrigeration
Aermec WWM0500 604 tons · Chiller ×1
Generators
Cummins 300DQDAC L2 250 kW · Generator ×1
02/24/2026Permit IssuedNAVILLUS TILE INCVentilation Systems
Ventilation
Greenheck SQ-9-M1-VG 1,000 CFM · Exhaust Fan ×2
06/30/2025——Ventilation Systems
Ventilation
Greenheck SQ-160 1,800 CFM · Exhaust Fan ×1
1 job · most recent 06/30/2025
FiledStatusContractorScope
06/30/2025——40 heads
2 jobs · most recent 04/07/2026
Storm Water/Sanitary
FiledStatusContractorScope
04/07/2026——Storm, Water/Sanitary
02/24/2026Permit IssuedFORSYTHE PLBG & HTG CORPStorm, Water/Sanitary
4 jobs · most recent 04/07/2026
Steel Concrete
FiledStatusContractorScope
04/07/2026——1 scope_items
04/07/2026——Steel, Concrete
02/24/2026Permit IssuedFORSYTHE PLBG & HTG CORP3 scope_items
06/30/2025——Steel, Concrete
1 job · most recent 04/07/2026
Fence
FiledStatusContractorScope
04/07/2026Permit IssuedNAVILLUS TILE INCFence
Building Lifecycle
All (160)Filed (56)Permit Issued (8)Violation (1)Objection (65)Special Inspection (30)
08/31/2026
Permit issued — Plumbing
S01126745-S9-PL
07/21/2026
Special inspection requirement — Structural Stability – Alterations of existing buildings
STEPHEN LATUS
07/07/2026
Special inspection requirement — Concrete - Cast-In-Place
STEPHEN LATUS
06/18/2026
Violation issued (ECB, closed)
Construction
05/28/2026
Special inspection requirement — Structural Steel - Details
STEPHEN LATUS
05/28/2026
Special inspection requirement — Post-installed Anchors
STEPHEN LATUS
05/14/2026
Permit issued — Plumbing
S01126745-S9-PL
04/28/2026
Special inspection requirement — Fenestration and door U-factor and product ratings
04/28/2026
Special inspection requirement — Air barrier - visual inspection
04/28/2026
Special inspection requirement — Post-installed Anchors
04/28/2026
Special inspection requirement — Protection of exposed foundation insulation
04/28/2026
Special inspection requirement — Energy Code Compliance Inspections
04/28/2026
Special inspection requirement — Fire-Resistant Penetrations and Joints
04/28/2026
Special inspection requirement — Air barrier — testing
04/28/2026
Special inspection requirement — Fire-Resistance Rated Construction
04/28/2026
Special inspection requirement — Insulation placement and R values
04/28/2026
Special inspection requirement — Fenestration air leakage
04/28/2026
Special inspection requirement — Fenestration areas
04/28/2026
Special inspection requirement — Air barrier continuity plan testing
04/28/2026
Special inspection requirement — Masonry
04/28/2026
Special inspection requirement — Sprayed fire-resistant materials
04/28/2026
Special inspection requirement — Mastic and Intumescent Fire-resistant Coatings
04/28/2026
Special inspection requirement — Vestibules
04/28/2026
Special inspection requirement — Wall Panels, Curtain Walls, and Veneers
04/28/2026
Special inspection requirement — Concrete - Cast-In-Place
04/28/2026
Special inspection requirement — Subgrade Inspections
04/20/2026
Objection raised — Other
04/14/2026
Permit issued — Plumbing
S01126745-S4-PL
04/10/2026
Permit issued — Mechanical Systems
S01126745-S7-GC-CX
04/08/2026
Permit issued — Structural
S01126745-Z3-GC-CX
04/07/2026
Filed — Alteration
Construction Fence in conjunction with site preparation (Phase 2) work.
S01348776-P1
04/07/2026
Filed — Alteration
SOE FOR PHASE 2 SITE PREPARATION (EARTHWORK) AND FUTURE NEW BUILDINGS IN PHASE 3.
S01370998-I1
04/07/2026
Filed — New Building
Saint John Villa Campus - R123 - IS/HS: Subsequent filing of Emergency Generator work type for new 5-story school building. APPLICATION FILED IN CONJUNCTION WITH DOB # S01126745, S01144839, S01192239, S01192240, S01192242, S01192243, 500877063
S01149913-P1
04/07/2026
Objection resolved — Addressed
04/06/2026
Permit issued — Earth Work
S01126745-Z2-GC-CX
04/02/2026
Permit issued — General Construction
S01126745-I1-GC
03/30/2026
Special inspection requirement — Mastic and Intumescent Fire-resistant Coatings
03/30/2026
Special inspection requirement — Concrete - Cast-In-Place
03/30/2026
Special inspection requirement — Fire-Resistant Penetrations and Joints
03/30/2026
Special inspection requirement — Masonry
03/30/2026
Special inspection requirement — Post-installed Anchors
03/30/2026
Special inspection requirement — Sprayed fire-resistant materials
03/30/2026
Special inspection requirement — Subgrade Inspections
03/26/2026
Objection resolved — Addressed
03/26/2026
Objection resolved — Addressed
03/06/2026
Permit issued — Construction Fence
S01348776-I1-FN
02/24/2026
Filed — Alteration
SAINT JOHN VILLA: SUBSEQUENT CIVIL PLUMBING WORK TYPE FOR PHASE II SITE PREPARATION OF A NEW SCHOOL COMPLEX. JOB FILED IN CONJUCTION S01144839, S01149913, 500877063
S01126745-P9
02/24/2026
Filed — Alteration
SAINT JOHN VILLA: SUBSEQUENT CIVIL PLUMBING WORK TYPE FOR PHASE II SITE PREPARATION OF A NEW SCHOOL COMPLEX. JOB FILED IN CONJUCTION S01144839, S01149913, 500877063
S01126745-P6
02/24/2026
Filed — Alteration
SAINT JOHN VILLA: SUBSEQUENT CIVIL PLUMBING WORK TYPE FOR PHASE II SITE PREPARATION OF A NEW SCHOOL COMPLEX. JOB FILED IN CONJUCTION S01144839, S01149913, 500877063
S01126745-P5
02/24/2026
Filed — Alteration
SAINT JOHN VILLA: SUBSEQUENT CIVIL PLUMBING WORK TYPE FOR PHASE II SITE PREPARATION OF A NEW SCHOOL COMPLEX. JOB FILED IN CONJUCTION S01144839, S01149913, 500877063
S01126745-P1
02/24/2026
Filed — Alteration
SAINT JOHN VILLA: SUBSEQUENT CIVIL PLUMBING WORK TYPE FOR PHASE II SITE PREPARATION OF A NEW SCHOOL COMPLEX. JOB FILED IN CONJUCTION S01144839, S01149913, 500877063
S01126745-P7
02/24/2026
Filed — Alteration
SAINT JOHN VILLA: SUBSEQUENT CIVIL PLUMBING WORK TYPE FOR PHASE II SITE PREPARATION OF A NEW SCHOOL COMPLEX. JOB FILED IN CONJUCTION S01144839, S01149913, 500877063
S01126745-P2
02/24/2026
Filed — Alteration
SAINT JOHN VILLA: SUBSEQUENT CIVIL PLUMBING WORK TYPE FOR PHASE II SITE PREPARATION OF A NEW SCHOOL COMPLEX. JOB FILED IN CONJUCTION S01144839, S01149913, 500877063
S01126745-P3
02/19/2026
Filed — Alteration
SAINT JOHN VILLA: SUBSEQUENT CIVIL PLUMBING WORK TYPE FOR PHASE II SITE PREPARATION OF A NEW SCHOOL COMPLEX. JOB FILED IN CONJUCTION S01144839, S01149913, 500877063
S01126745-P4
02/19/2026
Filed — Alteration
SAINT JOHN VILLA: SUBSEQUENT CIVIL PLUMBING WORK TYPE FOR PHASE II SITE PREPARATION OF A NEW SCHOOL COMPLEX. JOB FILED IN CONJUCTION S01144839, S01149913, 500877063
S01126745-P8
02/09/2026
Filed — No Work
S01356118-I1
02/05/2026
Objection resolved — Addressed
02/03/2026
Objection resolved — Addressed
02/02/2026
Objection resolved — Addressed
01/30/2026
Objection resolved — Addressed
Latest 60 of 160 events.
▾Owner History (Filing Record)
Companies and organizations named on filings. Individual owners are not shown.
OwnerFilingsMost Recent
NYC SCHOOL CONSTRUCTION AUTHORITY5909/13/2026
▾Design Consultants (Architect / Engineer of Record)
▾Filing Representatives (Expediters)
RepresentativeFilingsMost Recent
JMV ASSOCIATES10403/21/2026
▾Contractors (License-Anchored)
FirmTradeRolesMost Recent
NAVILLUS TILE INCGeneral Contractor504/12/2026
FORSYTHE PLBG & HTG CORPPlumbing209/01/2026
FRANCO BELLI PLMG&HTG SONPlumbing106/28/2026
▾Special Inspection Agencies
AgencyLicense #FilingsMost Recent
MUNICIPAL TESTING LABORAT2302104/07/2026
Permit / Filing Register
SourceWork TypeStatusApplicantIssued
DOB NOWPlumbingPermit IssuedFORSYTHE PLBG & HTG CORP08/31/2026
DOB NOWPlumbingPermit IssuedFRANCO BELLI PLMG&HTG SON05/14/2026
DOB NOWPlumbingPermit IssuedFORSYTHE PLBG & HTG CORP04/14/2026
DOB NOWMechanical SystemsPermit IssuedNAVILLUS TILE INC04/10/2026
DOB NOWStructuralPermit IssuedNAVILLUS TILE INC04/08/2026
DOB NOWEarth WorkPermit IssuedNAVILLUS TILE INC04/06/2026
DOB NOWGeneral ConstructionPermit IssuedNAVILLUS TILE INC04/02/2026
DOB NOWConstruction FencePermit IssuedNAVILLUS TILE INC03/06/2026
▾Special Inspection Requirements (DOB NOW) — 150
DateRequirementInspectorRole
07/21/2026Structural Stability – Alterations of existing buildingsSTEPHEN LATUSspecial
07/07/2026Concrete - Cast-In-PlaceSTEPHEN LATUSspecial
05/28/2026Structural Steel - DetailsSTEPHEN LATUSspecial
05/28/2026Post-installed AnchorsSTEPHEN LATUSspecial
04/28/2026Masonry—special
04/28/2026Subgrade Inspections—special
04/28/2026Concrete - Cast-In-Place—special
04/28/2026Wall Panels, Curtain Walls, and Veneers—special
04/28/2026Post-installed Anchors—special
04/28/2026Fire-Resistance Rated Construction—progress
04/28/2026Air barrier — testing —energy_progress
04/28/2026Insulation placement and R values—energy_progress
04/28/2026Sprayed fire-resistant materials—special
04/28/2026Mastic and Intumescent Fire-resistant Coatings—special
04/28/2026Fire-Resistant Penetrations and Joints—special
04/28/2026Fenestration air leakage—energy_progress
04/28/2026Air barrier - visual inspection—energy_progress
04/28/2026Fenestration and door U-factor and product ratings—energy_progress
04/28/2026Air barrier continuity plan testing—energy_progress
04/28/2026Fenestration areas—energy_progress
04/28/2026Vestibules—energy_progress
04/28/2026Protection of exposed foundation insulation—energy_progress
04/28/2026Energy Code Compliance Inspections—progress
03/30/2026Fire-Resistant Penetrations and Joints—special
03/30/2026Air barrier continuity plan testing—energy_progress
Latest 25 of 150.
▾Documents — 368 on file (BIS + DOB NOW)
▸Plans & Drawings59
▸DOB NOWPlans/Sketch54
08/20/2026S01149913-I1Request digital key ↗
08/20/2026S01149913-S1Request digital key ↗
08/20/2026S01149913-S2Request digital key ↗
Showing 3 of 54 on file for this type
▸DOB NOWPlans/Sketch - Place of Assembly5
08/20/2026S01192240-I1Request digital key ↗
08/20/2026S01192242-I1Request digital key ↗
08/20/2026S01192239-I1Request digital key ↗
Showing 3 of 5 on file for this type
▸Applications & Permits5
▸DOB NOWDEP Stormwater Construction Permit5
On file, but not among the 200 most recently loaded documents for this source.
Showing 0 of 5 on file for this type
▸Zoning, Tax Lot & Property Records6
▸DOB NOWHouse Number Verification: TOPO Stamp2
On file, but not among the 200 most recently loaded documents for this source.
Showing 0 of 2 on file for this type
▸DOB NOWZoning Exhibit form (1-5)2
08/20/2026S01149913-I1Open ↗
Showing 1 of 2 on file for this type
▸DOB NOWZD1: DOB Zoning Diagram2
On file, but not among the 200 most recently loaded documents for this source.
Showing 0 of 2 on file for this type
▸Seals & Professional Certifications94
▸DOB NOWDPL-1: Design Professional Seal & Signature59
08/20/2026S01149913-Z5Open ↗
08/20/2026S01149913-I1Open ↗
08/20/2026S01149913-S1Open ↗
Showing 3 of 59 on file for this type
▸DOB NOWSpecial Inspector Seal & Signature22
09/02/2026S01126745-S4Open ↗
08/29/2026S01126745-S2Open ↗
08/29/2026S01126745-S2Open ↗
Showing 3 of 22 on file for this type
▸DOB NOWProgress Inspector Seal & Signature13
08/29/2026S01126745-S2Open ↗
08/28/2026S01126745-P8Open ↗
08/27/2026S01126745-P7Open ↗
Showing 3 of 13 on file for this type
▸Trade Schedules & Equipment3
▸DOB NOWDEP: Sewer Certification (Sanitary/Storm)3
On file, but not among the 200 most recently loaded documents for this source.
Showing 0 of 3 on file for this type
▸Safety & Tenant Protection6
▸DOB NOWStreet Tree Checklist4
08/13/2026S01149913-Z4Open ↗
Showing 1 of 4 on file for this type
▸DOB NOWNYCSCA - Approved Site Safety Plans2
08/17/2026S01348776-P1Open ↗
Showing 1 of 2 on file for this type
▸Inspections & Test Reports8
▸DOB NOWSOIL REPORT5
08/20/2026S01126745-Z3Open ↗
08/13/2026S01149913-S2Open ↗
08/13/2026S01144839-Z3Open ↗
Showing 3 of 5 on file for this type
▸DOB NOWTR4 Test Report and Plot Diagram2
08/20/2026S01126745-Z3Open ↗
08/13/2026S01149913-S2Open ↗
▸DOB NOWTR4: Test Report and Plot Diagram1
On file, but not among the 200 most recently loaded documents for this source.
Showing 0 of 1 on file for this type
▸Approvals, Objections & Sign-offs113
▸DOB NOWFee Exempt Supporting Document - DOF ACRIS report or BIB letter59
08/20/2026S01126745-Z4Open ↗
08/20/2026S01126745-S4Open ↗
08/20/2026S01126745-S7Open ↗
Showing 3 of 59 on file for this type
▸DOB NOWDesign Commission Approval City Owned (Exterior Work)54
08/20/2026S01126745-Z2Open ↗
08/20/2026S01126745-I1Open ↗
08/20/2026S01126745-S8Open ↗
Showing 3 of 54 on file for this type
▸Other Documents74
▸DOB NOWNYCSCA - BCC Plan Examination Transmittal60
08/20/2026S01126745-Z4Open ↗
08/20/2026S01126745-Z3Open ↗
08/20/2026S01126745-I1Open ↗
Showing 3 of 60 on file for this type
▸DOB NOWSite Survey: Initial4
On file, but not among the 200 most recently loaded documents for this source.
Showing 0 of 4 on file for this type
▸DOB NOWLocal Law 92/94 of 2019 Sustainable Roof Zone4
On file, but not among the 200 most recently loaded documents for this source.
Showing 0 of 4 on file for this type
▸DOB NOWAdjoining Owners Notification2
08/20/2026S01126745-Z2Open ↗
08/17/2026S01370998-I1Open ↗
▸DOB NOWProperty Ownership Certification2
08/20/2026S01149913-I1Open ↗
08/20/2026S01149913-P1Open ↗
▸DOB NOWAlternate Plan 11
08/20/2026S01192240-I1Open ↗
▸DOB NOWAlternate Plan 21
08/20/2026S01192240-I1Open ↗