ECB01/14/2000FIRE STOPPING AT PARTY WALLS OF BUILDING IS NOT PROVIDED , CONTRARY TOREQUIREMENTS OF SECTION 27-332 OF THE BUILDING CODE.$-800 due
ECB05/13/2004NEW BUILDING OCCUPIED WITHOUT A VALID CERTIFICATE OF OCCUPANCY.NOTED C OF O #301112999-03 EXPIRED MAY 28,2003. REMEDY:OBTAIN VALID C OF O.Nothing owed — awaiting certificate of correction
ECB01/14/2000SKYLIGHT AND VENTILATORS FOR STAIR ENCLOSURE ARE NOT PROVIDED AS PER SECTION 27-375 (I) (4) (C) OF THE BUILDING CODE . REMDY; FILE PLANS TO LEGALIZE IF FEASIBLENothing owed — awaiting certificate of correction
ECB01/14/2000SECOND MEANS OF EGRESS FOR FOUR STORY BUILDING, CONSTRUCTION CLASS #B , IS NOT PROVIDED AS PER SECTION 27-366 OF THE BUILDING CODE. REMEDY: FILE PLANS TO LEGALIZE IF FEASIBLE..Nothing owed — awaiting certificate of correction
ECB01/14/2000EXISTING APARTMENT DOOR OPEN DIRECTLY INTO STAIR ENCLOSURE CONTRARY TO SECTION 27-375 (J) REMEDY: FILE PLANS TO LEGALIZE IF FEASIBLENothing owed — awaiting certificate of correction
ECB01/14/2000ROOF ACCESS IS MISSING IN THAT BUIDLING MORE THAN THREE STORIES OR FORTY FEET HIGH SHALL HAVE AN ACCESS TO THAT ROOF BY AT LEAST ONE INTERIOR STAIR AS PER SECTION 27-375 (K) OF THE BUIDLING CODE. REMEDY: FILE PNothing owed — awaiting certificate of correction
ECB01/14/2000STAIR ENCLOSURE DOES NOT COMPLY WITH THE REQUIRED FIRE RESISTANCE RATING , IN THAT THE BUILDING IS BUILT AS A FOUR STORY , OCCUPANCY GROUP J-Z , WHICH REQUIRES A TWO- HOUR FIRE RATED ENCLOSURE AS PER SECTION 2Nothing owed — awaiting certificate of correction
ECB01/14/2000BULKHEAD OF FIRE RESISTANT CONSTRUCTION MEETING THE REQUIREMENTS OF SUB CHAPTER FIVE OF THE BUILDING CODE IS NOT PROVIDED AS PER 27-375 (K) (1). FILE PLANS TO LEGLAIZE IF FEASIBLE.Nothing owed — awaiting certificate of correction
ECB01/14/2000HANDICAP ACCESS TO THE BUILDING IS NOT PROVIDED AS PER SECTION 27-292.5(A) OF THE BUILDING CODE. FILE PLANS TO LEGALIZE IF FEASIBLE.Nothing owed — awaiting certificate of correction
ECB01/14/2000BUILDING DOES NOT COMPLY WITH QUALITY HOUSING PROGRAM AS PER SECTIONS 28-12 AND 28-22 OF THE ZONING RESOLUTION IN THAT THERE ARE NO DOUBLE GLAZED WINDOWS NOR REQUIRED PLANTINGS. FILE TO LEGALIZE.Nothing owed — awaiting certificate of correction
ECB01/14/2000WOOD STAIR BETWEEN CELLAR AND FIRST FLOOR IS NOT PERMITTED AS PER SECTION 27-375 (H) REMEDY : MAKE STAIR OF NON - COMBUSTIBLE MATERIALS AS REQUIRED BY CODE AND OBTAIN DOB INSPECTIONNothing owed — awaiting certificate of correction
ECB01/14/2000PARAPET ON EXTERIOR WALL OF BUILDING IS NOT PROVIDED AT THE ROOF OF THE FOURTH FLOOR AS PER SECTION 27-333 OF THE BUILDING CODE. FILE PLANS TO LEGALIZE IF FEASIBLE.Nothing owed — awaiting certificate of correction
ECB01/14/2000STRUCTURAK DEFECTS OBSERVED IN VIOLATION OF REFRENCE STANDARD RS 10-5 B, AS FOLLOWS, NO STRAP BRACING FOR "C" 013 (3 PRESENT; NO ANCHORAGE BETWEEN JOIST AND BEARING OR NON BEARING WALL; NO STIFFENING OF JOISTSNothing owed — awaiting certificate of correction
ECB01/13/2000ROOF ACCESS IS MISSING IN THAT BUILDINGS MORE THAN THRE STORIES OR FORTY FEET HIGH SHALL HAVE AN ACCESS TO THE ROOF BY AT LEAST ONE INTERIORTAIR AS PER SECTION 27-375 (K) OF THE BUILDING CODE.REMEDY: FILE PLANSNothing owed — awaiting certificate of correction
ECB01/13/2000EXISTING APARTMENT DOORS OPEN DIRECTLY INTO STAIR ENCLOSURE CONTRARY TO SECTION 27-375 (J) OF BUILDING CODE. REMEDY: FILE PLANS TO LEGALIZE IF FEASIBLENothing owed — awaiting certificate of correction
ECB01/13/2000WOOD STAIR BETWEEN CELLAR AND FIRST FLOOR IS NOT PERMITTED ,AS PER SECTION 27-375(H) REMEDY: MAKE STAIR OF NON-COMBUSTIBLE MATERIAL .AS REQUIRED BY CODE ,AND OBTAIN D.O.B INSPECTIONNothing owed — awaiting certificate of correction
ECB01/13/2000BULKHEAD OF FIRE RESISTANT CONSTRUCTION MEETING THE REQUIREMENTS OF SUB-CHAPTER FIVE OF THE BUILDING CODE IS NOT PROVIDED AS EPR 27-375 (K)(I) REMEDY: FILE PLANS TO LEGALIZE IF FEASIBLENothing owed — awaiting certificate of correction
ECB01/13/2000STAIR ENCLOSURE DOES NOT COMPLY WITH THE REQUIRED FIRE RESISTANCE RATING , IN THAT THE BUILDING IS BUILT AS A FOUR STORY ,OCCUPANCY GROUP J-2 , WHICH REQUIRES A TWO-HOUR FIRE RATED ENCLOSURE AS PER SECTION 27-3Nothing owed — awaiting certificate of correction
ECB01/13/2000HANDICAP ACCESS TO THE BUILDING IS NOT PROVIDED AS PER SECTION 27-292.5(A) OF THE BUILDING CODE. FILE PLANS TO LEGALIZE IF FEASIBEL.Nothing owed — awaiting certificate of correction
ECB01/13/2000PARAPER ON EXTERIOR WALL OF BUILDING IS NOT PROVIDED AT THE ROOF OF THE FOURTH FLOOR AS PER SECTION 27-333 OF THE BUILDING CODE. REMEDY: FILE PLANS TO LEGALIZE IF FEASIBLENothing owed — awaiting certificate of correction
ECB01/13/2000FIRE STOOPING AT PARTY WALLS OF BUILDING IS NOT PROVIDED CONTRARY TO REQUIREMENTS OF SECTION 27-332 OF THE BUILDING CODE. FILE PLANS TO LEGALIZE IF FEASIBLE.Nothing owed — awaiting certificate of correction
ECB01/13/2000STRUCTURAL DEFECTS WHICH VIOLATE REFRENCE STANDARD RS 10-5B WERE OBSERVED , IN THAT ; (I) NO STRAO BRACING FOR "C' JOISTS PRESENT (II ) ANCHORAGE BETWEEN JOISTS AND BEARING OR NON-BEARING WALL WAS NOT PROVIDEDNothing owed — awaiting certificate of correction
ECB01/13/2000BUILDING DOES NOT COMPLY WITH QUALITY HOUSING PRIGRAM AS PER SECTIONS 28-12 AND 28-22 OF THE ZONING RESOLUTION IN THAT THERE ARE NO DOUBLE WINDOWS NOR REQUIRED PLANTINGS. FILE PLANS TO LEGALIZE.Nothing owed — awaiting certificate of correction
ECB01/13/2000SECOND MEANS OF EGRESS FOR FOUR0 STORY BUILDING ,CONSTRUCTION CLASS 2B , IS NOT PROVIDED AS PER SECTION 27-366 OF THE BUILDING CODE. REMEDY: FILE PLANS TO LEGALIZE IF FEASIBLENothing owed — awaiting certificate of correction
ECB01/13/2000SKYLIGHT AND VENTILATORS FOR STAIR ENCLOSURE ARE NOT PROVIDED AS PER SECTION 27-375 (I)(4) C OF THE BUILDING CODE. REMEDY: FILE PLANS TO LEGALIZE IF FEASIBLENothing owed — awaiting certificate of correction
ECB01/04/2000CELLAR WAS CONVERTED INTO APARTMENTS CONTRARY TO CERTIFICATE OF OCCU- PANCY. REMEDY: DISCONTINUE ILLEGAL USE & FILE PLANS TO LEGALIZE IF FEASIBLE.Nothing owed — awaiting certificate of correction