← Back
Miscellaneous garage
450 ZEREGA AVENUE
BRONX · Castle Hill-Unionport · BIN 2021302
💬 Discuss this project
1959Year Built
3Stories
G9Building Class
M1-1Zoning
40,248 sfGross Floor Area
2Units
LL97 Covered1 Open Violation ▸
Miscellaneous garage · Owner of record: 635 COLUMBUS LLC · 40,800 sf lot · 0.99 FAR built · Flood zone X
Locations of Work
ArchitectureMechanical
Roof4p · 1 filing · 17 docs
Floor 11p · 2 filings · 20 docs
▾Owner History (Filing Record)
Companies and organizations named on filings. Individual owners are not shown.
OwnerFilingsMost Recent
GVC LTD.1203/22/2026
ZEREGA HILL PROPERTY303/21/2026
635 Columbus LLC103/22/2026
▾Sales History (ACRIS)
DatePriceUnitSeller → Buyer$/sf
02/03/2021$14.5M—ZEREGA HILL PROPERTIES LLC → 635 COLUMBUS LLC$360/sf building
▾Design Consultants (Architect / Engineer of Record)
FirmFilingsMost Recent
TSS ENGINEERS305/05/2022
▾Filing Representatives (Expediters)
RepresentativeFilingsMost Recent
JENNY FLORES EXPEDITING303/21/2026
▾Contractors (License-Anchored)
FirmTradeRolesMost Recent
LINDENWOOD HEATING & AIRGeneral Contractor303/21/2026
NEW PLBG & HTG CORPPlumbing303/22/2026
CLEMENT CHAMBERSElectrical203/21/2026
EZ RUNER CONSTRUCTION CORGeneral Contractor203/21/2026
▾Special Inspection Agencies
AgencyLicense #FilingsMost Recent
TSS ENGINEERS4492205/05/2022
Building Lifecycle
All (36)Filed (3)Permit Issued (2)Signed Off (1)Violation (19)Special Inspection (11)
01/08/2025
Violation issued (DOB, closed)
V*-DOB VIOLATION - DISMISSED
10/24/2024
Violation issued (ECB, closed)
Construction
05/02/2023
Violation issued (DOB, open)
V-DOB VIOLATION - ACTIVE
06/09/2022
Signed off — Alteration
HEREBY FILING FOR THE REMOVAL OF SPRAY BOOTH ON THE GROUND FLOOR. NO CHANGE IN USE, EGRESS OR OCCUPANCY.
X00524824-I1
06/08/2022
Permit issued — General Construction
X00524824-I1-GC
05/17/2022
Permit issued — Mechanical Systems
X00340595-I1-MS
05/06/2022
Special inspection requirement — Mechanical Systems
bassam (sam) rimawi
05/06/2022
Special inspection requirement — Fire-Resistant Penetrations and Joints
bassam (sam) rimawi
05/06/2022
Special inspection requirement — Final
bassam (sam) rimawi
05/06/2022
Special inspection requirement — Shutoff dampers
bassam (sam) rimawi
05/06/2022
Special inspection requirement — Duct leakage testing
bassam (sam) rimawi
05/06/2022
Special inspection requirement — HVAC and service water heating equipment
bassam (sam) rimawi
05/06/2022
Special inspection requirement — HVAC insulation and sealing
bassam (sam) rimawi
05/06/2022
Special inspection requirement — Maintenance information
bassam (sam) rimawi
05/06/2022
Special inspection requirement — Permanent certificate
bassam (sam) rimawi
05/06/2022
Special inspection requirement — HVAC and service water heating system controls
bassam (sam) rimawi
05/05/2022
Filed — Alteration
Hereby filing for the interior and exterior mechanical work, replacement of HVAC equipment, retrofitting of duct work, replacement of equipment and controls. No change in use, egress or occupancy.
X00340595-P1
06/23/2021
Filed — Alteration
HEREBY FILING FOR THE REMOVAL OF SPRAY BOOTH ON THE GROUND FLOOR. NO CHANGE IN USE, EGRESS OR OCCUPANCY.
X00524824-I1
05/19/2021
Special inspection requirement — Final
bassam (sam) rimawi
02/02/2021
Violation issued (DOB, closed)
V*-DOB VIOLATION - DISMISSED
11/02/2020
Violation issued (DOB, closed)
V*-DOB VIOLATION - DISMISSED
08/02/2020
Violation issued (DOB, closed)
V*-DOB VIOLATION - DISMISSED
07/29/2020
Filed — Alteration
Hereby filing for the interior and exterior mechanical work, replacement of HVAC equipment, retrofitting of duct work, replacement of equipment and controls. No change in use, egress or occupancy.
X00340595-I1
05/02/2020
Violation issued (DOB, closed)
V*-DOB VIOLATION - DISMISSED
02/07/2000
Violation issued (DOB, closed)
V*-DOB VIOLATION - DISMISSED
05/04/1998
Violation issued (DOB, closed)
V*-DOB VIOLATION - DISMISSED
05/04/1998
Violation issued (DOB, closed)
V*-DOB VIOLATION - DISMISSED
09/16/1997
Violation issued (DOB, closed)
V*-DOB VIOLATION - DISMISSED
09/16/1997
Violation issued (DOB, closed)
V*-DOB VIOLATION - DISMISSED
02/10/1997
Violation issued (DOB, closed)
V*-DOB VIOLATION - DISMISSED
08/29/1995
Violation issued (DOB, closed)
V*-DOB VIOLATION - DISMISSED
08/29/1995
Violation issued (DOB, closed)
V*-DOB VIOLATION - DISMISSED
06/09/1994
Violation issued (DOB, closed)
V*-DOB VIOLATION - DISMISSED
06/09/1994
Violation issued (DOB, closed)
V*-DOB VIOLATION - DISMISSED
04/23/1993
Violation issued (DOB, closed)
V*-DOB VIOLATION - DISMISSED
04/23/1993
Violation issued (DOB, closed)
V*-DOB VIOLATION - DISMISSED
Permit / Filing Register
SourceWork TypeStatusApplicantIssued
DOB NOWGeneral ConstructionSigned-offEZ RUNER CONSTRUCTION COR06/08/2022
DOB NOWMechanical SystemsPermit IssuedLINDENWOOD HEATING & AIR05/17/2022
BISSPISSUEDALLSTATE SPRINKLER CORP.02/26/1997
BISPLISSUEDLIKE-NU PLUMBING INC.11/14/1996
BIS—ISSUEDZEREGA HILL PROPERTIES LIC10/10/1996
BISBLISSUEDCOURT OIL HEATING CORPORATION05/18/1992
1 project · most recent 05/05/2022
Air Conditioning Systems
FiledStatusContractorScopeMake / Model / Capacity
05/05/2022Permit IssuedLINDENWOOD HEATING & AIRAir Conditioning Systems
Cooling
Carrier 24ACB 36,000 BTU · Condensing Unit ×4
25HNBG636A310 36,000 BTU · Condensing Unit ×2
Fujitsu AOU 24RLX 22,000 BTU · Condensing Unit ×4
AOU 18RLX 17,800 BTU · Condensing Unit ×2
Mrcool DIY-18-HP-WMAH-230AE 17,800 BTU · Condensing Unit ×2
DIY-24-HP-WMAH-230AE 24,000 BTU · Condensing Unit ×2
▾Special Inspection Requirements (DOB NOW) — 11
DateRequirementInspectorRole
05/06/2022Mechanical Systemsbassam (sam) rimawispecial
05/06/2022Fire-Resistant Penetrations and Jointsbassam (sam) rimawispecial
05/06/2022Finalbassam (sam) rimawiprogress
05/06/2022Shutoff dampersbassam (sam) rimawienergy_progress
05/06/2022Duct leakage testing bassam (sam) rimawienergy_progress
05/06/2022HVAC and service water heating equipment bassam (sam) rimawienergy_progress
05/06/2022HVAC insulation and sealing bassam (sam) rimawienergy_progress
05/06/2022Maintenance informationbassam (sam) rimawienergy_progress
05/06/2022Permanent certificatebassam (sam) rimawienergy_progress
05/06/2022HVAC and service water heating system controls bassam (sam) rimawienergy_progress
05/19/2021Finalbassam (sam) rimawiprogress
▾Documents — 27 on file (BIS + DOB NOW)
▸Plans & Drawings3
▸DOB NOWPlans/Sketch - Mechanical Systems2
08/24/2026X00340595-P1Request digital key ↗
08/24/2026X00340595-I1Request digital key ↗
▸DOB NOWPlans/Sketch1
08/25/2026X00524824-I1Request digital key ↗
▸Applications & Permits2
▸BISPLAN / WORK APPROVAL APPLICATION2
03/25/2015220258940Open ↗
04/17/2013220258940Open ↗
▸Seals & Professional Certifications15
▸DOB NOWProgress Inspector Seal & Signature9
09/02/2026X00340595-I1Open ↗
09/02/2026X00340595-I1Open ↗
09/02/2026X00340595-I1Open ↗
Showing 3 of 9 on file for this type
▸DOB NOWDPL-1: Design Professional Seal & Signature3
08/25/2026X00524824-I1Open ↗
08/13/2026X00340595-I1Open ↗
08/13/2026X00340595-P1Open ↗
▸DOB NOWSpecial Inspector Seal & Signature2
09/02/2026X00340595-I1Open ↗
09/02/2026X00340595-I1Open ↗
▸BISTECHNICAL REPORT: RESPONSIBILITY/CERTIFICATION1
08/16/2013220258940Open ↗
▸Environmental & Asbestos4
▸DOB NOWDEP ACP-5: Asbestos Assessment Report3
08/25/2026X00524824-I1Open ↗
08/13/2026X00340595-P1Open ↗
08/13/2026X00340595-I1Open ↗
▸BISASBESTOS: CERTIFICATION (DEP ACP5)1
04/17/2013220258940Open ↗
▸Energy Compliance1
▸BISTECHNICAL REPORT: ENERGY CODE PROGRESS INSPS1
08/16/2013220258940Open ↗
▸Cost, Insurance & Ownership1
▸BISCOST AFFIDAVIT1
08/16/2013220258940Open ↗
▸Filing & Intake Forms1
▸BISEFILING COVER SHEET1
04/17/2013220258940Open ↗