← Back
BuildNYC
Two family brick
4508 GLENDALE COURT
BROOKLYN · Flatlands · BIN 3213383
💬 Discuss this project
1945Year Built
2Stories
B1Building Class
R4Zoning
1,560 sfGross Floor Area
2Units
4 Active Violations 3 unresolved · 1 paperwork only 3 old, status unconfirmed ▸FDNY Report ↗
Two family brick · 1,892 sf lot · 0.82 FAR built · Flood zone X
Locations of Work
ArchitectureMechanicalPlumbingGeneral
Names shown beside floors are taken automatically from the text of filed documents and may be incomplete or wrong.
Permit Issued — active, not yet Signed-off
Roof2p · 1 filing · 11 docs
Floor 27p · 1 filing · 11 docs
Floor 1Under Construction13p · 3 filings · 20 docs
CellarUnder Construction17p · 3 filings · 20 docs
BasementUnder Construction10p · 2 filings · 20 docs
Sub-Basement1 filing · 3 docs
Site & exterior5p · 1 filing · 11 docs
▾Sales History (ACRIS)
DatePriceUnitSeller → Buyer$/sf
03/12/2015$406K—GOSHEN MORTGAGE REO LLC → Private party$260/sf building
10/18/2013$309K—Private party → GOSHEN MORTGAGE REO LLC$198/sf building
▾Design Consultants (Architect / Engineer of Record)
FirmFilingsMost Recent
PWR Engineering Design907/12/2026
▾Filing Representatives (Expediters)
RepresentativeFilingsMost Recent
KMP Design Engineering403/21/2026
KP Consulting Engineer803/21/2026
PWR Engineering Design103/21/2026
▾Contractors (License-Anchored)
FirmTradeRolesMost Recent
Seva Property DevlopmentGeneral Contractor210/10/2026
RM ElectricElectrical103/22/2026
Seva Property Devlopmentspecialty_contractor110/16/2026
Signore & Sons PlumbingPlumbing111/19/2026
▾Special Inspection Agencies
AgencyLicense #FilingsMost Recent
IP Concrete Testing and I6252407/12/2026
Building Lifecycle
11/16/2026
Permit issued — Plumbing
B01362966-S3-PL
10/19/2026
Failure to comply with the permitted fence height noted. At time of inspection, observed white metal fence at erected at exposure 1 of property is…
ECB violation · open
10/19/2026
At time of inspection, observed metal fence at exposure 1 of property is approximately 6FT, and metal pan fence at exposure 2 is approximately 5FT,…
ECB violation · open
10/15/2026
Permit issued — Mechanical Systems
B01362966-S2-MS
10/09/2026
Permit issued — General Construction
B01362966-I1-GC
91 history events on file for this building. Sign in free to see the full history. Sign in · Create account
Permit / Filing Register
SourceWork TypeStatusApplicantIssued
DOB NOWPlumbingPermit IssuedSignore & Sons Plumbing11/16/2026
DOB NOWMechanical SystemsPermit IssuedSeva Property Devlopment10/15/2026
DOB NOWGeneral ConstructionPermit IssuedSeva Property Devlopment10/09/2026
DOB NOWGeneral ConstructionPermit IssuedSeva Property Devlopment10/21/2024
1 project · most recent 07/12/2026
Heating and Air Conditioning Systems
FiledStatusContractorScope
07/12/2026Permit IssuedSeva Property DevlopmentHeating and Air Conditioning Systems
2 projects · most recent 07/12/2026
Gas Water/Sanitary
FiledStatusContractorScope
07/12/2026Permit IssuedSignore & Sons PlumbingGas, Water/Sanitary
01/03/2025——Gas, Water/Sanitary
1 project · most recent 07/23/2026
General Wiring
FiledStatusContractorScope
07/23/2026Permit IssuedRM ElectricGeneral Wiring
▾Special Inspection Requirements (DOB NOW) — 35
DateRequirementInspectorRole
06/16/2026Fire-Resistant Penetrations and Joints—special
03/30/2026Structural Stability – Alterations of existing buildingsINDARDEO PARBHUNATHspecial
03/10/2026Permanent certificateINDARDEO PARBHUNATHenergy_progress
02/25/2026Fenestration air leakageINDARDEO PARBHUNATHenergy_progress
02/25/2026Interior lighting powerINDARDEO PARBHUNATHenergy_progress
02/25/2026Fire-Resistance Rated ConstructionINDARDEO PARBHUNATHprogress
02/25/2026Fire-Resistant Penetrations and JointsINDARDEO PARBHUNATHspecial
02/25/2026Energy Code Compliance InspectionsINDARDEO PARBHUNATHprogress
02/25/2026Fenestration and door U-factor and product ratingsINDARDEO PARBHUNATHenergy_progress
02/25/2026Maintenance informationINDARDEO PARBHUNATHenergy_progress
02/25/2026Fenestration areasINDARDEO PARBHUNATHenergy_progress
02/25/2026Insulation placement and R valuesINDARDEO PARBHUNATHenergy_progress
02/25/2026Air barrier - visual inspectionINDARDEO PARBHUNATHenergy_progress
07/21/2025Permanent certificate—energy_progress
07/21/2025Maintenance information—energy_progress
06/25/2025Fire-Resistant Penetrations and Joints—special
06/25/2025Structural Stability – Alterations of existing buildings—special
06/25/2025Energy Code Compliance Inspections—progress
06/25/2025Fire-Resistance Rated Construction—progress
06/25/2025Fenestration and door U-factor and product ratings—energy_progress
06/25/2025Insulation placement and R values—energy_progress
06/25/2025Fenestration areas—energy_progress
06/25/2025Interior lighting power—energy_progress
06/25/2025Fenestration air leakage—energy_progress
06/25/2025Air barrier - visual inspection—energy_progress
Latest 25 of 35.
48 filed documents on file for this building. Sign in free to see the full history. Sign in · Create account