← Back
BuildNYC
Two family frame
451 STAFFORD AVENUE
STATEN ISLAND · BIN 5081307
💬 Discuss this project
1985Year Built
2Stories
B2Building Class
R3XZoning
3,064 sfGross Floor Area
2Units
Two family frame · 8,000 sf lot · 0.38 FAR built · Flood zone X
Locations of Work
ArchitectureStructural
Names shown beside floors are taken automatically from the text of filed documents and may be incomplete or wrong.
Roof3p · 1 filing · 20 docs
Floor 22p · 1 filing · 20 docs
Floor 16p · 1 filing · 20 docs
▾Design Consultants (Architect / Engineer of Record)
FirmFilingsMost Recent
Lauria Associates309/12/2023
▾Filing Representatives (Expediters)
RepresentativeFilingsMost Recent
Quickfast603/21/2026
▾Contractors (License-Anchored)
FirmTradeRolesMost Recent
Bell Construction of NYGeneral Contractor903/21/2026
▾Special Inspection Agencies
AgencyLicense #FilingsMost Recent
Lauria Associates7570309/12/2023
Building Lifecycle
01/16/2024
Signed off — Alteration
Renovate and enlarge existing 2 family dwelling.
S00551430-I1
09/22/2023
Special inspection requirement — Structural Steel - Details
EDWARD LAURIA
09/22/2023
Special inspection requirement — Concrete - Cast-In-Place
EDWARD LAURIA
09/22/2023
Special inspection requirement — Subgrade Inspections
EDWARD LAURIA
09/22/2023
Special inspection requirement — Fire-Resistant Penetrations and Joints
EDWARD LAURIA
34 history events on file for this building. Sign in free to see the full history. Sign in · Create account
Permit / Filing Register
SourceWork TypeStatusApplicantIssued
DOB NOWStructuralSigned-offBell Construction of NY07/13/2023
DOB NOWStructuralSigned-offBell Construction of NY07/13/2023
DOB NOWFoundationSigned-offBell Construction of NY06/05/2023
1 project · most recent 06/12/2023
General Wiring
FiledStatusContractorScope
06/12/2023CompleteKriscorp Electrical ContngGeneral Wiring
▾Special Inspection Requirements (DOB NOW) — 27
DateRequirementInspectorRole
09/22/2023Structural Steel - DetailsEDWARD LAURIAspecial
09/22/2023Concrete - Cast-In-PlaceEDWARD LAURIAspecial
09/22/2023Subgrade InspectionsEDWARD LAURIAspecial
09/22/2023Fire-Resistant Penetrations and JointsEDWARD LAURIAspecial
09/22/2023Exterior Insulation and Finish Systems (EIFS)EDWARD LAURIAspecial
09/22/2023Energy Code Compliance InspectionsEDWARD LAURIAprogress
09/22/2023Footing and FoundationEDWARD LAURIAprogress
09/22/2023Fire-Resistance Rated ConstructionEDWARD LAURIAprogress
09/22/2023FinalEDWARD LAURIAprogress
09/22/2023Fenestration areasEDWARD LAURIAenergy_progress
09/22/2023Air barrier - visual inspectionEDWARD LAURIAenergy_progress
09/22/2023Insulation placement and R valuesEDWARD LAURIAenergy_progress
09/22/2023Fenestration and door U-factor and product ratingsEDWARD LAURIAenergy_progress
09/22/2023Fenestration air leakageEDWARD LAURIAenergy_progress
06/20/2023Concrete - Cast-In-PlaceEDWARD LAURIAspecial
06/20/2023Fire-Resistant Penetrations and JointsEDWARD LAURIAspecial
06/20/2023Structural Steel - DetailsEDWARD LAURIAspecial
06/20/2023Subgrade InspectionsEDWARD LAURIAspecial
06/20/2023Energy Code Compliance InspectionsEDWARD LAURIAprogress
06/20/2023FinalEDWARD LAURIAprogress
06/20/2023Fire-Resistance Rated ConstructionEDWARD LAURIAprogress
06/20/2023Air barrier - visual inspectionEDWARD LAURIAenergy_progress
06/20/2023Fenestration air leakageEDWARD LAURIAenergy_progress
06/20/2023Insulation placement and R valuesEDWARD LAURIAenergy_progress
06/20/2023Fenestration and door U-factor and product ratingsEDWARD LAURIAenergy_progress
Latest 25 of 27.