← Back
Over six families without stores
453 3 STREET
BROOKLYN · BIN 3021032
💬 Discuss this project
1920Year Built
5Stories
C1Building Class
R6BZoning
11,092 sfGross Floor Area
8Units
Rent Stabilized5 Open Violations ▸FDNY Report ↗
Over six families without stores · Owner of record: 453 3RD OWNER LLC · 4,394 sf lot · 2.52 FAR built · Flood zone X
Locations of Work
MechanicalPlumbingGeneral
Roof1p · 1 filing · 19 docs
Floor 43p · 2 filings · 20 docs
Floor 3
Floor 21p · 1 filing · 18 docs
Floor 1
Cellar2p · 1 filing · 18 docs
▾Owner History (Filing Record)
Companies and organizations named on filings. Individual owners are not shown.
OwnerFilingsMost Recent
PEAK1307/08/2026
453 3RD OWNER LLC103/22/2026
JKO USA MANAGEMENT203/22/2026
▾Sales History (ACRIS)
DatePriceUnitSeller → Buyer$/sf
06/09/2023$8.1M—— → —$730/sf building
▾Design Consultants (Architect / Engineer of Record)
FirmFilingsMost Recent
JAMES CHAI ARCHITECT, P.C.610/05/2023
▾Filing Representatives (Expediters)
RepresentativeFilingsMost Recent
RICHARD WAINER ARCHITECT, PLLC1203/21/2026
▾Contractors (License-Anchored)
FirmTradeRolesMost Recent
BADGER MANAGEMENT INCGeneral Contractor403/21/2026
JKO USA MANAGEMENT INCGeneral Contractor307/08/2026
PIPESTYLISTS, INCPlumbing207/08/2026
▾Special Inspection Agencies
AgencyLicense #FilingsMost Recent
JAMES JH CHAI & ASSOCIATE6481610/05/2023
Building Lifecycle
All (136)Filed (6)Permit Issued (6)Signed Off (6)Violation (60)Inspection (6)Objection (22)Special Inspection (30)
12/19/2023
Signed off — Alteration
RENOVATE UNIT #4L @ 4TH FLOOR, INCLUDE REMOVING AND INSTALLING NEW INTERIOR NON-LOAD BEARING PARTITIONS, LIGHTING AND FINISH WORK. NO CHANGE TO USE, EGRESS OR OCCUPANCY.
B00936470-S1
12/04/2023
Signed off — Alteration
RENOVATE UNIT #4L @ 4TH FLOOR, INCLUDE REMOVING AND INSTALLING NEW INTERIOR NON-LOAD BEARING PARTITIONS, LIGHTING AND FINISH WORK. NO CHANGE TO USE, EGRESS OR OCCUPANCY.
B00936470-I1
11/30/2023
Signed off — Alteration
RENOVATE UNIT #4L @ 4TH FLOOR, INCLUDE REMOVING AND INSTALLING NEW INTERIOR NON-LOAD BEARING PARTITIONS, LIGHTING AND FINISH WORK. NO CHANGE TO USE, EGRESS OR OCCUPANCY.
B00936470-S2
11/29/2023
Violation issued (DOB, closed)
V*-DOB VIOLATION - DISMISSED
11/27/2023
Inspection — Certified Water and Sanitary-WS-Fixtures-Finish
Certified
View inspection ↗
11/22/2023
Violation issued (DOB, closed)
V*-DOB VIOLATION - DISMISSED
11/02/2023
Inspection — Certified Water and Sanitary-WS-Sanitary Piping-Roughing
Certified
View inspection ↗
10/19/2023
Permit issued — Plumbing
B00936470-S2-PL
10/19/2023
Permit issued — Mechanical Systems
B00936470-S1-MS
10/12/2023
Permit issued — General Construction
B00936470-I1-GC
10/10/2023
Objection raised — Admin
10/10/2023
Objection resolved — Addressed
10/10/2023
Objection raised — Scope
10/10/2023
Objection resolved — Addressed
10/10/2023
Objection raised — Scope
10/10/2023
Objection resolved — Addressed
10/05/2023
Filed — Alteration
RENOVATE UNIT #4L @ 4TH FLOOR, INCLUDE REMOVING AND INSTALLING NEW INTERIOR NON-LOAD BEARING PARTITIONS, LIGHTING AND FINISH WORK. NO CHANGE TO USE, EGRESS OR OCCUPANCY.
B00936470-S1
10/05/2023
Filed — Alteration
RENOVATE UNIT #4L @ 4TH FLOOR, INCLUDE REMOVING AND INSTALLING NEW INTERIOR NON-LOAD BEARING PARTITIONS, LIGHTING AND FINISH WORK. NO CHANGE TO USE, EGRESS OR OCCUPANCY.
B00936470-S2
10/05/2023
Special inspection requirement — HVAC-R and service water heating system controls
Joon Ho Chai
10/05/2023
Special inspection requirement — HVAC-R and service water piping design and insulation
Joon Ho Chai
10/05/2023
Special inspection requirement — HVAC-R and service water heating equipment
Joon Ho Chai
10/05/2023
Special inspection requirement — Maintenance information
Joon Ho Chai
10/03/2023
Special inspection requirement — Tenant Protection Plan Compliance
Joon Ho Chai
10/03/2023
Special inspection requirement — Fire-Resistant Penetrations and Joints
Joon Ho Chai
10/03/2023
Special inspection requirement — Energy Code Compliance Inspections
Joon Ho Chai
09/27/2023
Objection raised — Other
09/27/2023
Objection resolved — Addressed
09/27/2023
Objection raised — Other
09/27/2023
Objection resolved — Addressed
09/27/2023
Objection raised — Scope
09/27/2023
Objection resolved — Addressed
09/27/2023
Objection raised — Other
09/27/2023
Objection resolved — Addressed
09/27/2023
Objection raised — Zoning
09/27/2023
Objection resolved — Addressed
09/27/2023
Objection raised — Other
09/27/2023
Objection resolved — Addressed
09/27/2023
Objection raised — Inspections
09/27/2023
Objection resolved — Addressed
09/27/2023
Objection raised — Scope
09/27/2023
Objection resolved — Addressed
09/27/2023
Special inspection requirement — Air barrier - visual inspection
Joon Ho Chai
09/25/2023
Filed — Alteration
RENOVATE UNIT #4L @ 4TH FLOOR, INCLUDE REMOVING AND INSTALLING NEW INTERIOR NON-LOAD BEARING PARTITIONS, LIGHTING AND FINISH WORK. NO CHANGE TO USE, EGRESS OR OCCUPANCY.
B00936470-I1
09/25/2023
Signed off — Alteration
RENOVATE UNITS #1L, 1R, 2L, 2R, 3L, 3R, 4R & COMMON HALLWAY FROM CELLAR TO ROOF, INCLUDE REMOVING AND INSTALLING NEW INTERIOR NON-LOAD BEARING PARTITIONS, LIGHTING AND FINISH WORK. NO CHANGE TO USE, EGRESS OR OCCUPANCY.
B00891350-S1
09/20/2023
Special inspection requirement — Lighting in dwelling units
Joon Ho Chai
09/20/2023
Special inspection requirement — Fire-Resistant Penetrations and Joints
Joon Ho Chai
09/20/2023
Special inspection requirement — Tenant Protection Plan Compliance
Joon Ho Chai
09/20/2023
Special inspection requirement — Final
JIN WOO LEE
09/20/2023
Special inspection requirement — Energy Code Compliance Inspections
Joon Ho Chai
09/20/2023
Special inspection requirement — Fire-Resistance Rated Construction
Joon Ho Chai
09/20/2023
Special inspection requirement — Fenestration air leakage
Joon Ho Chai
09/20/2023
Special inspection requirement — Interior lighting power
Joon Ho Chai
09/20/2023
Special inspection requirement — Fenestration and door U-factor and product ratings
Joon Ho Chai
09/20/2023
Special inspection requirement — Fenestration areas
Joon Ho Chai
09/19/2023
Signed off — Alteration
RENOVATE UNITS #1L, 1R, 2L, 2R, 3L, 3R, 4R & COMMON HALLWAY FROM CELLAR TO ROOF, INCLUDE REMOVING AND INSTALLING NEW INTERIOR NON-LOAD BEARING PARTITIONS, LIGHTING AND FINISH WORK. NO CHANGE TO USE, EGRESS OR OCCUPANCY.
B00891350-I1
09/19/2023
Signed off — Alteration
RENOVATE UNITS #1L, 1R, 2L, 2R, 3L, 3R, 4R & COMMON HALLWAY FROM CELLAR TO ROOF, INCLUDE REMOVING AND INSTALLING NEW INTERIOR NON-LOAD BEARING PARTITIONS, LIGHTING AND FINISH WORK. NO CHANGE TO USE, EGRESS OR OCCUPANCY.
B00891350-S2
09/05/2023
Inspection — Certified Water and Sanitary-WS-Fixtures-Finish
Certified
View inspection ↗
07/28/2023
Inspection — Certified Water and Sanitary-WS-Sanitary Piping-Roughing
Certified
View inspection ↗
07/28/2023
Inspection — Certified Water and Sanitary-WS-Sanitary Piping-Underground
Certified
View inspection ↗
07/26/2023
Inspection — Certified Remove/Cap - work done in accordance with code
Certified
View inspection ↗
Latest 60 of 136 events.
Permit / Filing Register
SourceWork TypeStatusApplicantIssued
DOB NOWPlumbingSigned-offT & T PLUMBING INC10/19/2023
DOB NOWMechanical SystemsSigned-offBADGER MANAGEMENT10/19/2023
DOB NOWGeneral ConstructionSigned-offBADGER MANAGEMENT10/12/2023
DOB NOWMechanical SystemsSigned-offJKO USA MANAGEMENT07/18/2023
DOB NOWPlumbingSigned-offT & T PLUMBING INC06/28/2023
DOB NOWGeneral ConstructionSigned-offJKO USA MANAGEMENT06/24/2023
BISOTISSUEDN/N01/07/1999
2 projects · most recent 12/20/2023
General Wiring
FiledStatusContractorScope
12/20/2023CompleteE & M ELECTRICAL NY CORPGeneral Wiring
09/24/2023CompleteE & M ELECTRICAL NY CORPGeneral Wiring
▾Field Inspections (DOB CAP) — 6
DateTypeResultReport
11/27/2023Certified Water and Sanitary-WS-Fixtures-FinishCertifiedView ↗
11/02/2023Certified Water and Sanitary-WS-Sanitary Piping-RoughingCertifiedView ↗
09/05/2023Certified Water and Sanitary-WS-Fixtures-FinishCertifiedView ↗
07/28/2023Certified Water and Sanitary-WS-Sanitary Piping-RoughingCertifiedView ↗
07/28/2023Certified Water and Sanitary-WS-Sanitary Piping-UndergroundCertifiedView ↗
07/26/2023Certified Remove/Cap - work done in accordance with codeCertifiedView ↗
▾Special Inspection Requirements (DOB NOW) — 34
DateRequirementInspectorRole
10/05/2023HVAC-R and service water heating system controlsJoon Ho Chaienergy_progress
10/05/2023HVAC-R and service water piping design and insulationJoon Ho Chaienergy_progress
10/05/2023HVAC-R and service water heating equipmentJoon Ho Chaienergy_progress
10/05/2023Maintenance informationJoon Ho Chaienergy_progress
10/03/2023Tenant Protection Plan ComplianceJoon Ho Chaispecial
10/03/2023Fire-Resistant Penetrations and JointsJoon Ho Chaispecial
10/03/2023Energy Code Compliance InspectionsJoon Ho Chaiprogress
09/27/2023Air barrier - visual inspectionJoon Ho Chaienergy_progress
09/20/2023Lighting in dwelling unitsJoon Ho Chaienergy_progress
09/20/2023Fire-Resistant Penetrations and JointsJoon Ho Chaispecial
09/20/2023Tenant Protection Plan ComplianceJoon Ho Chaispecial
09/20/2023FinalJIN WOO LEEprogress
09/20/2023Energy Code Compliance InspectionsJoon Ho Chaiprogress
09/20/2023Fire-Resistance Rated ConstructionJoon Ho Chaiprogress
09/20/2023Fenestration air leakageJoon Ho Chaienergy_progress
09/20/2023Interior lighting powerJoon Ho Chaienergy_progress
09/20/2023Fenestration and door U-factor and product ratingsJoon Ho Chaienergy_progress
09/20/2023Fenestration areasJoon Ho Chaienergy_progress
06/16/2023Energy Code Compliance InspectionsJoon Ho Chaiprogress
06/16/2023Tenant Protection Plan ComplianceJoon Ho Chaispecial
06/16/2023Fire-Resistant Penetrations and JointsJoon Ho Chaispecial
06/16/2023HVAC-R and service water heating system controlsJoon Ho Chaienergy_progress
06/16/2023Maintenance informationJoon Ho Chaienergy_progress
06/16/2023HVAC-R and service water piping design and insulationJoon Ho Chaienergy_progress
06/16/2023HVAC-R and service water heating equipmentJoon Ho Chaienergy_progress
Latest 25 of 34.
▾Documents — 37 on file (BIS + DOB NOW)
▸Plans & Drawings6
▸DOB NOWPlans/Sketch6
08/27/2026B00891350-S1Request digital key ↗
08/27/2026B00891350-S2Request digital key ↗
08/27/2026B00891350-I1Request digital key ↗
Showing 3 of 6 on file for this type
▸Seals & Professional Certifications25
▸DOB NOWProgress Inspector Seal & Signature13
09/23/2026B00891350-S2Open ↗
09/01/2026B00936470-S2Open ↗
09/01/2026B00936470-S2Open ↗
Showing 3 of 13 on file for this type
▸DOB NOWDPL-1: Design Professional Seal & Signature6
08/27/2026B00891350-S1Open ↗
08/27/2026B00891350-S2Open ↗
08/27/2026B00891350-I1Open ↗
Showing 3 of 6 on file for this type
▸DOB NOWSpecial Inspector Seal & Signature6
09/23/2026B00891350-S2Open ↗
09/01/2026B00936470-S2Open ↗
08/27/2026B00936470-I1Open ↗
Showing 3 of 6 on file for this type
▸Environmental & Asbestos6
▸DOB NOWDEP ACP-5: Asbestos Assessment Report6
08/27/2026B00891350-S1Open ↗
08/27/2026B00891350-S2Open ↗
08/27/2026B00891350-I1Open ↗
Showing 3 of 6 on file for this type