← Back
BuildNYC
Two family converted from one family
453 OLMSTEAD AVENUE
BRONX · Castle Hill-Unionport · BIN 2021001
💬 Discuss this project
1965Year Built
3Stories
B3Building Class
R5Zoning
2,218 sfGross Floor Area
2Units
1 Active Violation ▸
Two family converted from one family · 1,980 sf lot · 1.12 FAR built · Flood zone X
Locations of Work
ArchitecturePlumbingEquipmentCivil
Names shown beside floors are taken automatically from the text of filed documents and may be incomplete or wrong.
Roof1p · 1 filing · 20 docs
Floor 31 filing · 20 docs
Floor 21 filing · 20 docs
Floor 1Unit 1B14p · 2 filings · 20 docs
Site & exteriorConstruction fence and yard work1p · 1 filing · 2 docs
▾Sales History (ACRIS)
DatePriceUnitSeller → Buyer$/sf
09/26/2016$373K—Private party → Private party$168/sf building
▾Design Consultants (Architect / Engineer of Record)
FirmFilingsMost Recent
Banji Awosika Architect606/21/2025
▾Filing Representatives (Expediters)
RepresentativeFilingsMost Recent
Banji Architect1203/21/2026
▾Contractors (License-Anchored)
FirmTradeRolesMost Recent
Dfe ContractorGeneral Contractor303/21/2026
Moken Home ImprovementGeneral Contractor203/21/2026
Moken Home ImprovementScaffold203/21/2026
Just Plumbing & HeatingPlumbing207/08/2026
Dfe ContractorScaffold107/08/2026
▾Special Inspection Agencies
AgencyLicense #FilingsMost Recent
Banji Awosika Architect P2721506/21/2025
Building Lifecycle
07/07/2025
Special inspection requirement — Fire-Resistant Penetrations and Joints
OLABANJI AWOSIKA
07/07/2025
Special inspection requirement — Structural Stability – Alterations of existing buildings
OLABANJI AWOSIKA
07/07/2025
Special inspection requirement — Excavations - Sheeting, Shoring, and Bracing
OLABANJI AWOSIKA
07/07/2025
Special inspection requirement — Fenestration air leakage
OLABANJI AWOSIKA
07/07/2025
Special inspection requirement — Air barrier - visual inspection
OLABANJI AWOSIKA
59 history events on file for this building. Sign in free to see the full history. Sign in · Create account
Permit / Filing Register
SourceWork TypeStatusApplicantIssued
DOB NOWPlumbingSigned-offMohamed Abdelrazek08/16/2024
DOB NOWPlumbingSigned-offMohamed Abdelrazek12/01/2022
DOB NOWEarth WorkPermit IssuedDfe Contractor10/25/2022
DOB NOWConstruction FenceSigned-offDfe Contractor10/25/2022
DOB NOWConstruction FenceSigned-offMoken Home Improvement09/23/2022
DOB NOWEarth WorkPermit IssuedMoken Home Improvement08/10/2022
1 project · most recent 01/07/2025
General Wiring
FiledStatusContractorScope
01/07/2025CompleteWCK ElectricGeneral Wiring
1 project · most recent 06/21/2025
FiledStatusContractorScope
06/21/2025Permit IssuedDfe Contractor—
▾Field Inspections (DOB CAP) — 7
DateTypeResultReport
05/23/2025Pass-Final CND-Occupancy InspectionPassView ↗
02/14/2025Pass-Final CND-Occupancy InspectionPassView ↗
09/09/2024Certified Storm Drainage-ST-Fixtures-FinishCertifiedView ↗
09/05/2024Certified Storm Drainage-ST-Piping-RoughingCertifiedView ↗
09/05/2024Certified Storm Drainage-ST-Piping-UndergroundCertifiedView ↗
12/22/2022Certified Water and Sanitary-WS-Sanitary Piping-RoughingCertifiedView ↗
12/22/2022Certified Water and Sanitary-WS-Sanitary Piping-UndergroundCertifiedView ↗
▾Special Inspection Requirements (DOB NOW) — 63
DateRequirementInspectorRole
07/07/2025Concrete - Cast-In-PlaceOLABANJI AWOSIKAspecial
07/07/2025Structural Stability – Alterations of existing buildingsOLABANJI AWOSIKAspecial
07/07/2025Private On-Site Storm Water Disposal Systems-, and Detention Facilities, InstallationOLABANJI AWOSIKAspecial
07/07/2025Fire-Resistant Penetrations and JointsOLABANJI AWOSIKAspecial
07/07/2025MasonryOLABANJI AWOSIKAspecial
07/07/2025Energy Code Compliance InspectionsOLABANJI AWOSIKAprogress
07/07/2025Footing and FoundationOLABANJI AWOSIKAprogress
07/07/2025Fire-Resistance Rated ConstructionOLABANJI AWOSIKAprogress
07/07/2025Subgrade InspectionsOLABANJI AWOSIKAspecial
07/07/2025Fenestration and door U-factor and product ratingsOLABANJI AWOSIKAenergy_progress
07/07/2025MeteringOLABANJI AWOSIKAenergy_progress
07/07/2025Fenestration areasOLABANJI AWOSIKAenergy_progress
07/07/2025Air barrier - visual inspectionOLABANJI AWOSIKAenergy_progress
07/07/2025Fenestration air leakageOLABANJI AWOSIKAenergy_progress
07/07/2025Interior lighting powerOLABANJI AWOSIKAenergy_progress
07/07/2025FinalOLABANJI AWOSIKAprogress
07/07/2025Excavations - Sheeting, Shoring, and BracingOLABANJI AWOSIKAspecial
06/20/2025Fire-Resistant Penetrations and JointsOLABANJI AWOSIKAspecial
06/20/2025Private On-Site Storm Water Disposal Systems-, and Detention Facilities, InstallationOLABANJI AWOSIKAspecial
06/20/2025Structural Stability – Alterations of existing buildingsOLABANJI AWOSIKAspecial
06/20/2025Subgrade InspectionsOLABANJI AWOSIKAspecial
06/20/2025Energy Code Compliance InspectionsOLABANJI AWOSIKAprogress
06/20/2025FinalOLABANJI AWOSIKAprogress
06/20/2025Fire-Resistance Rated ConstructionOLABANJI AWOSIKAprogress
06/20/2025Footing and FoundationOLABANJI AWOSIKAprogress
Latest 25 of 63.
52 filed documents on file for this building. Sign in free to see the full history. Sign in · Create account