ECB02/17/2026STOP ALL SOE WORK ENTIRE SITE. AT THE TIME OF INSPECTION I OBSERVED SOE WORK NOT CONFORMING TO THE APPROVED PLANS. THE 1 TO 1 SLOPE IS NOT MAINTAINED CREATING A CAUGHT IN BETWEEN OR CRUSHED HAZARD. COMPLY WITH$1K due
ECB02/17/2026CONSTRUCTION SUPERINTENDENT FAILED TO PERFORM DUTIES AS REQUIRED BY CODE. THE CONSTRUCTION SUPERINTENDENT WAS NOT ON SITE AND THE COMPETENT PERSON COULD NOT PROVIDE THE CONSTRUCTION SUPERINTENDENT LOG BOOK AS R$5K due
ECB02/17/2026AT THE TIME OF INSPECTION I OBSERVED INADEQUATE GUARDRAILS AT EXPOSURE 1 AT AN ONGOING SUPPORT OF EXCAVATION SITE. THE GUARDRAILS WERE MISSING ADEQUATE INTERLOCKING DEVICES AND WERE NOT AT THE REQUIRED HEIGHT.$2K due
DOB11/14/2025VIOLATION ISSUED-FAILURE TO FILE 2024 EXTERNAL LOW PRESSURE INSPECTION
DOB11/14/2025VIOLATION ISSUED-FAILURE TO FILE 2024 EXTERNAL LOW PRESSURE INSPECTION
DOB11/14/2025VIOLATION ISSUED-FAILURE TO FILE 2024 EXTERNAL LOW PRESSURE INSPECTION
DOB02/22/2012V-DOB VIOLATION - ACTIVE
ECB04/03/2026RE-ISSUE #35692457H. FAILURE TO MAINTAIN BUILDING IN CODE-COMPLIANT MANNER. ILLUMINATION FOR EXITS, EXIT DISCHARGES AND PUBLIC CORRIDORS PERBC 1006.1; 27-381. NOTED: THERE WERE SEVERAL EMERGENCY LIGHTS THAT WERNothing owed — awaiting certificate of correction
ECB04/03/2026FAILURE TO MAINTAIN BUILDING IN CODE-COMPLIANT MANNER. NOTED: THERE WERE MANY CLASSROOMS THROUGHOUT THE SCHOOL WITH ONE OR MORE OF THE FOLLOWING HAZARDOUS CONDITIONS. COMBUSTIBLE MATERIALS HANGING FROM CEILINGNothing owed — awaiting certificate of correction
ECB04/03/2026RE-ISSUE #35692455Y. ALTERED/CHANGED BUILDING OCCUPIED WITHOUT A VALIDC OF O. NOTED: AT T. O. I. THE TEMPORARY C OF O THAT EXPIRED IN 1989, HAS NOT BEEN UPDATED OR RENEWED. REMEDY: OBTAIN VALID CERTIFICATE OF ONothing owed — awaiting certificate of correction
ECB05/06/2025FAILURE TO MAINTAIN BUILDING IN CODE-COMPLIANT MANNER; ILLUMINATION FOR EXITS, EXIT DISCHARGES AND PUBLIC CORRIDORS PER BC 1006.1; 27-381. NOTED: AT T. O. I., THERE WERE SEVERAL EMERGENCY LIGHTS SCATTERED THROUNothing owed — awaiting certificate of correction
ECB05/06/2025RE-ISSUE #35678826N. BUILDING ALTERED/CHANGED OCCUPIED WITHOUT A VALIDC OF O. NOTE: THE TEMPORARY C OF O THAT EXPIRED IN 1989 HAS NOT BEEN UPDATED AND/OR RENEWED TO DATE. REMEDY: OBTAIN A VALID C OF O.Nothing owed — awaiting certificate of correction
ECB03/12/2024RE-ISSUE #35665343X. BUILDING OCCUPIED W/O VALID C OF O. NOTE: THIS SCHOOL IS 100% OCCUPIED AND NO CURRENT C OF O IS ON FILE. REMEDY: OBTAINVALID C OF O.Nothing owed — awaiting certificate of correction
ECB02/02/2023REISSUE #35636509Y BUILDING OCCUPIED W/O VALID C OF O.NOTED:SCHOOL IS 100% OCCUPIED WITH NO UPDATED VALID CERTIFICATE OF OCCUPANCY.REMEDY:OBTAIN C OF O.Nothing owed — awaiting certificate of correction
ECB02/02/2023REISSUE #35636507K FAILURE TO MAINTAIN BUILDING IN CODE COMPLIANT MANNER.NOTED:RETAINING WALL AT ALL 4 EXPOSURES IN NEED OF SERIOUS REPAIRS.LARGE CRACKS MISSING BRICKS & MORE.REMEDY:REPAIR/REPLACENothing owed — awaiting certificate of correction
ECB02/08/2022REISSUE#35555836R.BUILDING IS OCCUPIED WITHOUT A VALID COFO.OBSERVED AT TOI THIS SCHOOL IS FULLY OCCUPIED AND OPERATING WITHOUT A CURRENT UPDATED COFO.REMEDY:OBTAIN A VALID COFO.Nothing owed — awaiting certificate of correction
ECB02/08/2022REISSUE#35555838K.FAILURE TO MAINTAIN BUILDING IN CODE COMPLIANT MANNER.OBSERVED AT TIME OF INSPECTIN THE RETAINING WALLS AT ALL 4 EXPOSURESIN NEED OF SERIOUS REPAIR.BRICKS ARE MISSING,CRACKED AND BULGING.CAP SNothing owed — awaiting certificate of correction
ECB04/19/2021REISSUE35502141L ALTERED CHANGED BLDG OCCUPIED W/O VALID C/O PER BC28-118.3.1&BC28-118.3.2 NOTE TCO73141 EXPIRED6/89 NO NEW C/O.OBTAIN VALIDC/O.Nothing owed — awaiting certificate of correction
ECB04/19/2021REISSUE35402138K FAILURE TO MAINTAIN BLDG WALLS OR APPURTENANCES NOTE RETAINING WALL IN STATE OF DISREPAIR ON ALL 4EXPS W/CRACKS&BULGING BRICKS ALSO CAPSTONES ARE LOOSE W/MISSING MORTAR,FENCE POST LOOSE IN VARINothing owed — awaiting certificate of correction
ECB07/02/2020REISSUE ECB #35452247R FAILURE TO MAINTAIN BUILDING WALLS OR APPURTENANCES NOTE RETAINING WALL IN DISREPAIR WITH BULGING BRICK AND CRACKS ON ALL 4 SIDES VARIOUS AREAS MISSING CAP STONE AND MISSINGMORTAR FENCE PNothing owed — awaiting certificate of correction
ECB07/02/2020REISSUE #35452243J ALTERED CHANGED BUILDING OCCUPIED WITHOUT A VALID CERTIFICATE OF OCCUPANCY AS PER BC 28-118.3.1 AND BC 28-1118.3.2 NOTE TEMP C OF O #73141 EXPIRED 6-1989 OBTAIN A VALID CERTIFICATE OF OCCUPANNothing owed — awaiting certificate of correction
ECB09/04/2019REISSUED 335341926R ALTERED CHANGED BUILDING OCCUPIED WITHOUT A VALID CERTIFICATE OF OCCUPANCY AS PER BC 28-118.3.1& BC 28-118.3.2.NOTE TEMP C OF O #73141 EXPIRED 6/1989 OBTAIN A VALID CERTIFICATE OF OCCUPANCYNothing owed — awaiting certificate of correction
ECB09/04/2019FAILURE TO MAINTAIN BUILDING WALLS OR APPURTENANCE NOTE RETAINING WALL IN DISREPAIR WITH BULGING BRICK AND CRACKS ON ALL 4SIDES VARIOUS AREAS MISSING CAP STONE AND MISSING MPRTAR FENCE POST LOOSE IN AREAS REPAINothing owed — awaiting certificate of correction
ECB07/18/2018REISSUE #35271110N ALTERED/CHANGED BLDG OCCUPIED W/O A VALID COFO. NOTED: TEMP COFO #73141 EXP ON JUNE OF 1989. RMDY: OBTAIN A VALID COFORMDY: OBTAIN A VALID COFO.Nothing owed — awaiting certificate of correction
ECB06/20/2017REISSUE#35216439R ALTERED/CHANGED BLDG OCCUPIED W/O VALID C OF O. NOTED: TCO#73141 EXP ON 6/1989 NO VALID C OF O AVAILABLE. REMEDY: COMPLY W/SUMMONS. OBTAIN VALID C OF O.Nothing owed — awaiting certificate of correction
ECB10/25/2016REISSUE #35023158J ALTERED/CHANGED BUILDING OCCUPIED W/O A VALID CERTIFICATE OF OCCUPANCY. NOTED TEMPORARY CERTIFICATE OF OCCUPANCY. NO 73141 ISSUED BY THE BLDG DEPT, EXPIRED ON 06/01/1989. RMDY: OBTAIN VALIDNothing owed — awaiting certificate of correction
ECB06/14/2013TCO #73141 EXPIRED ON 6.1.1989. NO VALID C/O ON FILE. NB-810/1980. REMEDY: OBTAIN VALID C/O.Nothing owed — awaiting certificate of correction