← Back
Miscellaneous two family
457 WEST 153 STREET
MANHATTAN · Hamilton Heights-Sugar Hill · BIN 1061658
💬 Discuss this project
1891Year Built
3Stories
B9Building Class
R6AZoning
4,998 sfGross Floor Area
2Units
0 Open Violations
Miscellaneous two family · 4,596 sf lot · 1.09 FAR built · Flood zone X
Locations of Work
ArchitectureMechanicalPlumbing
Floor 34p · 1 filing · 14 docs
Floor 23p · 1 filing · 14 docs
Floor 15p · 1 filing · 14 docs
Sub-Basement3p · 1 filing · 14 docs
▾Design Consultants (Architect / Engineer of Record)
FirmFilingsMost Recent
A.S.III DESIGN STUDIO211/17/2023
▾Filing Representatives (Expediters)
RepresentativeFilingsMost Recent
PROFESSIONAL SOLUTIONS203/21/2026
▾Contractors (License-Anchored)
FirmTradeRolesMost Recent
MAMC CONSULTING REPS LLCGeneral Contractor303/21/2026
▾Special Inspection Agencies
AgencyLicense #FilingsMost Recent
ENGINEERING CONSULTING SE2050211/17/2023
Building Lifecycle
All (12)Filed (2)Permit Issued (1)Signed Off (1)Violation (4)Special Inspection (4)
02/23/2024
Signed off — Alteration
ENCLOSE EXISTING GAS RISERS IN RATED 2 HOUR CONSTRUCTION, FIRE STOP FLOOR PENETRATIONS AT 1st,2nd and 3rd FLOORS
M00916909-I1
02/08/2024
Permit issued — General Construction
M00916909-I1-GC
11/22/2023
Special inspection requirement — Fire-Resistant Penetrations and Joints
PAUL MARINO
11/22/2023
Special inspection requirement — Final
ALBERT SMITH III
11/17/2023
Filed — Alteration
ENCLOSE EXISTING GAS RISERS IN RATED 2 HOUR CONSTRUCTION, FIRE STOP FLOOR PENETRATIONS AT 1st,2nd and 3rd FLOORS
M00916909-P1
11/17/2023
Special inspection requirement — Fire-Resistant Penetrations and Joints
PAUL MARINO
11/17/2023
Special inspection requirement — Final
ALBERT SMITH III
11/06/2023
Filed — Alteration
ENCLOSE EXISTING GAS RISERS IN RATED 2 HOUR CONSTRUCTION, FIRE STOP FLOOR PENETRATIONS AT 1st,2nd and 3rd FLOORS
M00916909-I1
02/10/1997
Violation issued (DOB, closed)
V*-DOB VIOLATION - DISMISSED
08/29/1995
Violation issued (DOB, closed)
V*-DOB VIOLATION - DISMISSED
03/18/1994
Violation issued (DOB, closed)
V*-DOB VIOLATION - DISMISSED
03/18/1993
Violation issued (DOB, closed)
V*-DOB VIOLATION - DISMISSED
Permit / Filing Register
SourceWork TypeStatusApplicantIssued
DOB NOWGeneral ConstructionSigned-offMAMC CONSULTING REPS LLC02/08/2024
BIS—RE-ISSUEDG.D.C.02/26/1997
BISPLISSUEDG.D.C.02/26/1997
Nothing on file for this building.
▾Special Inspection Requirements (DOB NOW) — 4
DateRequirementInspectorRole
11/22/2023Fire-Resistant Penetrations and JointsPAUL MARINOspecial
11/22/2023FinalALBERT SMITH IIIprogress
11/17/2023Fire-Resistant Penetrations and JointsPAUL MARINOspecial
11/17/2023FinalALBERT SMITH IIIprogress
▾Documents — 14 on file (BIS + DOB NOW)
▸Plans & Drawings2
▸DOB NOWPlans/Sketch2
08/28/2026M00916909-I1Request digital key ↗
08/28/2026M00916909-P1Request digital key ↗
▸Applications & Permits2
▸DOB NOWLPC Approval/Permit2
08/13/2026M00916909-I1Open ↗
08/13/2026M00916909-P1Open ↗
▸Seals & Professional Certifications6
▸DOB NOWDPL-1: Design Professional Seal & Signature2
08/13/2026M00916909-P1Open ↗
08/13/2026M00916909-I1Open ↗
▸DOB NOWProgress Inspector Seal & Signature2
08/25/2026M00916909-I1Open ↗
08/24/2026M00916909-P1Open ↗
▸DOB NOWSpecial Inspector Seal & Signature2
08/25/2026M00916909-I1Open ↗
08/24/2026M00916909-P1Open ↗
▸Safety & Tenant Protection2
▸DOB NOWHPD-3: Single Room Occupancy Multiple Dwelling (SRO MD) Anti-Harassment Checklist2
08/13/2026M00916909-P1Open ↗
08/13/2026M00916909-I1Open ↗
▸Environmental & Asbestos2
▸DOB NOWDEP ACP-5: Asbestos Assessment Report2
08/13/2026M00916909-P1Open ↗
08/13/2026M00916909-I1Open ↗