← Back
One story retail building
458 NOME AVENUE
STATEN ISLAND · BIN 5111188
💬 Discuss this project
1989Year Built
1Stories
K1Building Class
R3-2Zoning
1,440 sfGross Floor Area
1Units
7 Open Violations ▸FDNY Report ↗
One story retail building · Owner of record: 2203 3RD AVE LLC · 3,450 sf lot · 0.42 FAR built · Flood zone X
Locations of Work
No floor-level scope or drawing coverage on file for this building.
▾Owner History (Filing Record)
Companies and organizations named on filings. Individual owners are not shown.
OwnerFilingsMost Recent
1498 ROCKAWAY REALTY1507/08/2026
CRYSTAL 1 HOUR CLEANERS103/22/2026
OWNER OF DRY CLEANERS103/22/2026
ALESI ENTERPRISES103/21/2026
▾Design Consultants (Architect / Engineer of Record)
FirmFilingsMost Recent
J&R DESIGN AND INSPECTION CORP.205/17/2023
SHEAN CHANG WANG ARCHITECT306/21/2022
▾Filing Representatives (Expediters)
RepresentativeFilingsMost Recent
DYNASTY DESIGN CONSULTING GROUP303/21/2026
HIGH QUALITY 338403/21/2026
▾Contractors (License-Anchored)
FirmTradeRolesMost Recent
HIGH QUALITY CONSTRUCTIONGeneral Contractor307/08/2026
AMERICAN STANDARD P&H CORORP.Plumbing107/08/2026
▾Special Inspection Agencies
AgencyLicense #FilingsMost Recent
J&R DESIGN AND INSPECTION6637205/17/2023
BUILDTECH ENGINEERING6369306/21/2022
Building Lifecycle
All (49)Filed (5)Permit Issued (3)Signed Off (1)Violation (12)Inspection (10)Special Inspection (18)
11/14/2025
Violation issued (DOB, open)
V-DOB VIOLATION - ACTIVE
11/14/2025
Violation issued (DOB, open)
V-DOB VIOLATION - ACTIVE
09/23/2024
Violation issued (DOB, open)
V-DOB VIOLATION - ACTIVE
09/23/2024
Violation issued (DOB, open)
V-DOB VIOLATION - ACTIVE
06/30/2023
Violation issued (DOB, open)
V-DOB VIOLATION - ACTIVE
05/18/2023
Signed off — Alteration
KITCHEN HOOD INSTALLATION ON AN EXISTING COMMERCIAL SPACE, NO CHANGE IN USE. AS PER PLANS FILED HEREWITH.
S00697415-I1
05/17/2023
Filed — Alteration
KITCHEN HOOD INSTALLATION ON AN EXISTING COMMERCIAL SPACE, NO CHANGE IN USE. AS PER PLANS FILED HEREWITH.
S00697415-P1
05/17/2023
Special inspection requirement — Mechanical Systems
Robert Truskosky
05/17/2023
Special inspection requirement — Structural Stability – Alterations of existing buildings
Robert Truskosky
05/17/2023
Special inspection requirement — Fire-Resistant Penetrations and Joints
Robert Truskosky
05/17/2023
Special inspection requirement — Smoke Control Systems Testing
Robert Truskosky
05/17/2023
Special inspection requirement — Final
Robert Truskosky
04/25/2023
Violation issued (DOB, open)
V-DOB VIOLATION - ACTIVE
04/25/2023
Violation issued (DOB, open)
V-DOB VIOLATION - ACTIVE
02/03/2023
Inspection — Fail-Final CND-Occupancy Inspection
Fail
View inspection ↗
01/25/2023
Inspection — Fail-Final CND-Occupancy Inspection
Fail
View inspection ↗
09/01/2022
Special inspection requirement — Structural Stability – Alterations of existing buildings
Robert Truskosky
09/01/2022
Special inspection requirement — Fire-Resistant Penetrations and Joints
Robert Truskosky
09/01/2022
Special inspection requirement — Mechanical Systems
Robert Truskosky
09/01/2022
Special inspection requirement — Smoke Control Systems Testing
Robert Truskosky
09/01/2022
Special inspection requirement — Final
Robert Truskosky
08/17/2022
Inspection — Pass-Final PL - Up to 3 Requested Floors
Pass
View inspection ↗
08/12/2022
Inspection — Pass-Final Solar
Pass
View inspection ↗
07/20/2022
Inspection — Fail-Final PL - Up to 3 Requested Floors
Fail
View inspection ↗
07/14/2022
Inspection — Pass-Final CND-Occupancy Inspection
Pass
View inspection ↗
07/13/2022
Inspection — Certified Gas-Gas-Piping-Roughing
Certified
View inspection ↗
07/13/2022
Inspection — Certified Water and Sanitary-WS-Sanitary Piping-Roughing
Certified
View inspection ↗
06/29/2022
Special inspection requirement — Fire-Resistant Penetrations and Joints
Luis Pichardo
06/21/2022
Filed — Alteration
Installation of plumbing work for a Commercial Kitchen for a Takeout Restaurant. no change in use, Egress, or Occupancy. as per Plans file herewith.
S00688722-P1
06/16/2022
Special inspection requirement — Fire-Resistant Penetrations and Joints
Luis Pichardo
05/09/2022
Inspection — Certified Water and Sanitary-WS-Sanitary Piping-Underground
Certified
View inspection ↗
04/22/2022
Permit issued — Mechanical Systems
S00697415-I1-MS
04/04/2022
Permit issued — Plumbing
S00688722-I1-PL
04/02/2022
Permit issued — General Construction
S00687374-I1-GC
03/23/2022
Filed — Alteration
KITCHEN HOOD INSTALLATION ON AN EXISTING COMMERCIAL SPACE, NO CHANGE IN USE. AS PER PLANS FILED HEREWITH.
S00697415-I1
03/23/2022
Filed — Alteration
Installation of plumbing work for a Commercial Kitchen for a Takeout Restaurant. no change in use, Egress, or Occupancy. as per Plans file herewith.
S00688722-I1
03/23/2022
Filed — Alteration
Installation of a Commercial Kitchen for a Takeout Restaurant. no change in use, Egress, or Occupancy. as per Plans file herewith.
S00687374-I1
03/13/2022
Special inspection requirement — Structural Stability – Alterations of existing buildings
Luis Pichardo
03/13/2022
Special inspection requirement — Interior lighting power
Luis Pichardo
03/13/2022
Special inspection requirement — Fenestration air leakage
Luis Pichardo
03/13/2022
Special inspection requirement — Lighting controls
Luis Pichardo
03/13/2022
Special inspection requirement — Insulation placement and R values
Luis Pichardo
03/13/2022
Special inspection requirement — Fire-Resistant Penetrations and Joints
Luis Pichardo
01/25/2022
Inspection — Fail-Final CND-Occupancy Inspection
Fail
View inspection ↗
03/16/2020
Violation issued (DOB, closed)
V*-DOB VIOLATION - DISMISSED
06/06/2001
Violation issued (ECB, closed)
Boilers
09/14/1993
Violation issued (FDNY_NOV, closed)
07/14/1993
Violation issued (ECB, closed)
Construction
06/07/1990
Violation issued (DOB, closed)
VP*-VIOLATION UNSERVED ECB- DISMISSED
Permit / Filing Register
SourceWork TypeStatusApplicantIssued
DOB NOWMechanical SystemsSigned-offHIGH QUALITY CONSTRUCTION04/22/2022
DOB NOWPlumbingPermit IssuedAMERICAN STANDARD P&H CORORP.04/04/2022
DOB NOWGeneral ConstructionPermit IssuedHIGH QUALITY CONSTRUCTION04/02/2022
BISPLISSUEDACE-ATLAS PLBING & HTG06/11/2008
BISBLISSUEDACE-ATLAS PLBING & HTG06/11/2008
BISMHISSUEDEIFFEL CORPORATION04/27/1999
1 project · most recent 06/21/2022
Gas
FiledStatusContractorScope
06/21/2022Permit IssuedAMERICAN STANDARD P&H CORGas
2 projects · most recent 06/09/2023
General Wiring
FiledStatusContractorScope
06/09/2023CompleteTANACHION ELEC'L CONT'G I—
04/07/2022Permit IssuedI.P. ELECTRIC INCGeneral Wiring
▾Field Inspections (DOB CAP) — 10
DateTypeResultReport
02/03/2023Fail-Final CND-Occupancy InspectionFailView ↗
01/25/2023Fail-Final CND-Occupancy InspectionFailView ↗
08/17/2022Pass-Final PL - Up to 3 Requested FloorsPassView ↗
08/12/2022Pass-Final SolarPassView ↗
07/20/2022Fail-Final PL - Up to 3 Requested FloorsFailView ↗
07/14/2022Pass-Final CND-Occupancy InspectionPassView ↗
07/13/2022Certified Gas-Gas-Piping-RoughingCertifiedView ↗
07/13/2022Certified Water and Sanitary-WS-Sanitary Piping-RoughingCertifiedView ↗
05/09/2022Certified Water and Sanitary-WS-Sanitary Piping-UndergroundCertifiedView ↗
01/25/2022Fail-Final CND-Occupancy InspectionFailView ↗
▾Special Inspection Requirements (DOB NOW) — 18
DateRequirementInspectorRole
05/17/2023Mechanical SystemsRobert Truskoskyspecial
05/17/2023Structural Stability – Alterations of existing buildingsRobert Truskoskyspecial
05/17/2023Fire-Resistant Penetrations and JointsRobert Truskoskyspecial
05/17/2023Smoke Control Systems TestingRobert Truskoskyspecial
05/17/2023FinalRobert Truskoskyprogress
09/01/2022Structural Stability – Alterations of existing buildingsRobert Truskoskyspecial
09/01/2022Fire-Resistant Penetrations and JointsRobert Truskoskyspecial
09/01/2022Mechanical SystemsRobert Truskoskyspecial
09/01/2022Smoke Control Systems TestingRobert Truskoskyspecial
09/01/2022FinalRobert Truskoskyprogress
06/29/2022Fire-Resistant Penetrations and JointsLuis Pichardospecial
06/16/2022Fire-Resistant Penetrations and JointsLuis Pichardospecial
03/13/2022Structural Stability – Alterations of existing buildingsLuis Pichardospecial
03/13/2022Interior lighting powerLuis Pichardoenergy_progress
03/13/2022Fenestration air leakageLuis Pichardoenergy_progress
03/13/2022Lighting controlsLuis Pichardoenergy_progress
03/13/2022Insulation placement and R valuesLuis Pichardoenergy_progress
03/13/2022Fire-Resistant Penetrations and JointsLuis Pichardospecial
▾Documents — 39 on file (BIS + DOB NOW)
▸Plans & Drawings5
▸DOB NOWPlans/Sketch5
08/24/2026S00687374-I1Request digital key ↗
08/24/2026S00688722-I1Request digital key ↗
08/24/2026S00688722-P1Request digital key ↗
Showing 3 of 5 on file for this type
▸Applications & Permits3
▸BISWORK PERMIT APPLICATION2
06/12/2008510043310Open ↗
06/12/2008510043310Open ↗
▸BISPLAN / WORK APPROVAL APPLICATION1
06/06/2008510043310Open ↗
▸Seals & Professional Certifications15
▸DOB NOWDPL-1: Design Professional Seal & Signature5
08/24/2026S00688722-I1Open ↗
08/24/2026S00688722-P1Open ↗
08/23/2026S00697415-I1Open ↗
Showing 3 of 5 on file for this type
▸DOB NOWSpecial Inspector Seal & Signature5
09/02/2026S00697415-P1Open ↗
09/01/2026S00688722-P1Open ↗
09/01/2026S00688722-I1Open ↗
Showing 3 of 5 on file for this type
▸DOB NOWProgress Inspector Seal & Signature3
09/02/2026S00697415-P1Open ↗
08/25/2026S00697415-I1Open ↗
08/24/2026S00687374-I1Open ↗
▸BISPROFESSIONAL CERTIFIED CHECKLIST1
06/06/2008510043310Open ↗
▸BISPROFESSIONAL CERTIFICATION STATEMENT FORM1
06/06/2008510043310Open ↗
▸Trade Schedules & Equipment4
▸BISSCHEDULE C - HEATING & COMBUSTION EQUIPMENT1
06/24/2008510043310Open ↗
▸BISBOILERS - SUPPORTING DOCUMENTATION1
05/26/2009510043310Open ↗
▸BISSELF-CERT PLUMBING NOTICE1
05/26/2009510043310Open ↗
▸BISSCHEDULE B - PLUMBING1
06/06/2008510043310Open ↗
▸Environmental & Asbestos6
▸DOB NOWDEP ACP-5: Asbestos Assessment Report5
08/24/2026S00688722-I1Open ↗
08/24/2026S00688722-P1Open ↗
08/23/2026S00697415-P1Open ↗
Showing 3 of 5 on file for this type
▸BISTHIS IS 'NOT AN ASBESTOS PROJECT'1
06/06/2008510043310Open ↗
▸Approvals, Objections & Sign-offs2
▸BISCERTIFICATE OF OCCUPANCY/LOC: REQUEST1
10/22/2009510043310Open ↗
▸BISADMINISTRATIVE OBJECTIONS1
06/06/2008510043310Open ↗
▸Cost, Insurance & Ownership3
▸BISCOST AFFIDAVIT3
10/22/2009510043310Open ↗
06/12/2008510043310Open ↗
06/12/2008510043310Open ↗
▸Filing & Intake Forms1
▸BISEFILING COVER SHEET1
06/06/2008510043310Open ↗