← Back
BuildNYC
Two family brick
46-04 OCEANIA STREET
QUEENS · Bayside · BIN 4156775
💬 Discuss this project
1955Year Built
2Stories
B1Building Class
R3-1Zoning
—Gross Floor Area
2Units
0 Active ViolationsFDNY Report ↗
Two family brick · 0.6 FAR built · Flood zone X
Locations of Work
No floor-level scope or filed-document coverage on file for this building.
▾Owner History (Filing Record)
Companies and organizations named on filings. Individual owners are not shown.
OwnerFilingsMost Recent
IW Construction203/22/2026
▾Contractors (License-Anchored)
FirmTradeRolesMost Recent
HI-Rite ElectricElectrical103/22/2026
Building Lifecycle
All (9)Violation (9)
08/01/2019
Closed: Unsafe buildings (DOB violation)
DOB violation · closed on the city's record
06/28/2019
Closed: Failure to certify correction on immediately hazardous (class 1) ECB violation
DOB violation · closed on the city's record
05/15/2019
Failure to comply with the commissioners order contained in summons/violation #35411655P issued on 3-6-19 and to file a certificate of correction…
ECB violation · closed
03/06/2019
Expired permit. Note: at time of my inspection of a 2STORY building with a sidewalk fence at exp 1,2,3 and 4. Review of dept records reveal that…
ECB violation · closed
03/06/2019
BC3307.7.5 fences.drawings. Note: at time of my inspection of a 2STORY bldg with work in progress. I observed a construcion fence erected at…
ECB violation · closed
07/11/2018
Failure to certify correction on immediately hazardous (class 1) ECB violation
DOB violation · closed · Issued 2018; DOB's record still lists it as active
06/08/2018
Work does not conform to approved construction documents. Failure to comply w/ the commissioner's order contained in summons/violation# 35327783H…
ECB violation · closed
04/18/2018
Work does not conform to approved construction documents &/or approvedamendments. Noted: at time of inspection observed 2ND fl joist in place…
ECB violation · closed
12/11/2017
Unsafe buildings (DOB violation)
DOB violation · closed · Issued 2017; DOB's record still lists it as active
Permit / Filing Register
SourceWork TypeStatusApplicantIssued
BISEQISSUEDJW Construction03/14/2019
BIS—ISSUEDJW Construction12/20/2018
BIS—ISSUEDJW Construction12/20/2018
BIS—ISSUEDJW Construction06/27/2018
BIS—ISSUEDJW Construction06/27/2018
BISPLISSUEDCatman Plumbing04/12/2018
BIS—ISSUEDCos Construction03/01/2018
BIS—ISSUEDCos Construction03/01/2018
BISEQISSUEDJW Construction02/20/2018
BIS—ISSUEDJW Construction02/20/2018
1 project · most recent 04/04/2019
General Wiring Lighting
FiledStatusContractorScope
04/04/2019CompleteHI-Rite ElectricGeneral Wiring, Lighting
Nothing on file for this building.
▾Documents — 62 on file (BIS + DOB NOW)
▸Applications & Permits13
▸BISWORK PERMIT APPLICATION6
03/19/2019421348777Open ↗
01/03/2019421348777Open ↗
07/06/2018421348777Open ↗
Showing 3 of 6 on file for this type
▸BISPLAN / WORK APPROVAL APPLICATION6
08/05/2019421348777Open ↗
11/10/2018421348777Open ↗
11/09/2018421193675Open ↗
Showing 3 of 6 on file for this type
▸BISCERTIFICATE OF OCCUPANCY: APPLICATION1
05/02/2019421348777Open ↗
▸Zoning, Tax Lot & Property Records1
▸BISZONING DIAGRAM1
10/30/2017421348777Open ↗
▸Seals & Professional Certifications13
▸BISTECHNICAL REPORT: RESPONSIBILITY/CERTIFICATION10
08/05/2019421348777Open ↗
04/05/2019421348777Open ↗
04/05/2019421348777Open ↗
Showing 3 of 10 on file for this type
▸BISPROFESSIONAL CERTIFIED CHECKLIST2
11/10/2018421348777Open ↗
10/08/2016421348777Open ↗
▸BISProfessional and Owner Certification (POC3)1
10/08/2016421348777Open ↗
▸Trade Schedules & Equipment6
▸BISSCHEDULE B - PLUMBING/SPRINKLER/STANDPIPE2
11/10/2018421348777Open ↗
10/08/2016421348777Open ↗
▸BISDETECTOR:SMOKE-CERT. OF INSTALLATION2
08/05/2019421348777Open ↗
08/05/2019421348777Open ↗
▸BISSEWER/HOUSE CON SIGNOFF: DEP HC 0212
05/14/2019421348777Open ↗
05/14/2019421348777Open ↗
▸Safety & Tenant Protection2
▸BISSTREET TREE CHECKLIST1
10/08/2016421348777Open ↗
▸BISDEMOLITION SUBMITTAL CERTIFICATION FORM1
02/21/2018421348777Open ↗
▸Environmental & Asbestos1
▸BISASBESTOS: CERTIFICATION (DEP ACP5)1
10/24/2017421348777Open ↗
▸Energy Compliance4
▸BISTECHNICAL REPORT: ENERGY CODE PROGRESS INSPS3
08/05/2019421348777Open ↗
02/21/2018421348777Open ↗
10/08/2016421348777Open ↗
▸BISAS-BUILT ENERGY ANALYSIS1
08/05/2019421348777Open ↗
▸Inspections & Test Reports2
▸BISTECHNICAL REPORT: SOIL INSPECTION2
02/21/2018421348777Open ↗
10/08/2016421348777Open ↗
▸Approvals, Objections & Sign-offs5
▸BISLETTERS - SUPPORTING DOCUMENTATION2
11/09/2018421193675Open ↗
11/29/2017421348777Open ↗
▸BISCERTIFICATE OF OCCUPANCY/LOC: REQUEST2
08/07/2019421348777Open ↗
08/05/2019421348777Open ↗
▸BISSCHEDULE A - OCCUPANCY / USE1
10/08/2016421348777Open ↗
▸Cost, Insurance & Ownership3
▸BISCOST AFFIDAVIT2
08/05/2019421348777Open ↗
10/08/2016421348777Open ↗
▸BISDEPT OF FINANCE VERIFICATION1
08/05/2019421348777Open ↗
▸Filing & Intake Forms10
▸BISADDITIONAL INFORMATION7
08/05/2019421348777Open ↗
06/19/2019421348777Open ↗
01/12/2019421348777Open ↗
Showing 3 of 7 on file for this type
▸BISEFILING COVER SHEET2
10/19/2017421193675Open ↗
10/08/2016421348777Open ↗
▸BISBPP: CHECKLIST IN LIEU OF PLANS-ALT31
10/19/2017421193675Open ↗
▸Other Documents2
▸BISPLOT DIAGRAM2
10/30/2017421348777Open ↗
10/08/2016421348777Open ↗