← Back
Predominantly retail with other uses
Bowery Theatre
46 BOWERY · BIN 1084353
💬 Discuss this project
1960Year Built
3Stories
K4Building Class
C6-1GZoning
47,500 sfGross Floor Area
14Units
LL97 Covered1 Open Violation 0 unresolved · 1 paperwork only ▸
Predominantly retail with other uses · 16,000 sf lot · 2.97 FAR built · Flood zone X
Locations of Work
ArchitectureStructuralMechanicalPlumbingFire ProtectionGeneral
Permit Issued — active, not yet Signed-off
Roof40p · 5 filings · 20 docs
Floor 3Under Construction16p · 4 filings · 20 docs
Floor 2Under Construction27p · 5 filings · 20 docs
Floor 1105p · 8 filings · 20 docs
Mezzanine2p · 1 filing · 13 docs
Cellar55p · 5 filings · 20 docs
Basement1p · 1 filing · 13 docs
3 jobs · most recent 06/25/2026
Heating and Air Conditioning Systems Ventilation Systems Associated Ducts and Piping Air Conditioning Systems Heating Systems
FiledStatusContractorScopeMake / Model / Capacity
06/25/2026Permit IssuedJD ARCH LLCAssociated Ducts and Piping, Heating and Air Conditioning Systems
Heat / Cool
Mitsubishi Electric MXZ-SM48NAMHZ 4 tons · Condensing Unit ×3
PVFY-P48NAMU-E1.1 4 tons · Vrf Indoor ×3
Ducts & Piping
N/A N/A 10,500 CFM · Exhaust Fan ×3
12/19/2024Permit IssuedWECUSTOM INCHeating and Air Conditioning Systems, Ventilation Systems
Heat / Cool
Fujitsu AUUA24TLAV2 24,000 BTU · Fan Coil Indoor ×10
AOU036LAVM4 36,000 BTU · Condensing Unit ×4
ASUB18TLAV2 18,000 BTU · Fan Coil Indoor ×4
AOUA120ULBV5 120,000 BTU · Vrf Outdoor ×2
AOUA96ULBV5 96,000 BTU · Vrf Outdoor ×2
ASUA12TLAV2 12,000 BTU · Fan Coil Indoor ×2
AUUA12TLAV2 12,000 BTU · Vrf Indoor ×2
Ventilation
Accurex XID-140 1,800 CFM · Kitchen Exhaust ×2
XUEF-15-5-B6-00-02-02 2,000 CFM · Kitchen Exhaust ×2
XUEF-22-3-B6-00-02-02 3,600 CFM · Exhaust Fan ×2
Fujitsu ARUH96TLAV2 2,855 CFM · Vrf Outdoor ×2
07/22/2024Permit IssuedWEBUILD INCAir Conditioning Systems, Heating Systems, Ventilation Systems
Cooling
Fujitsu AOU36RLAVM 3 tons · Condensing Unit ×3
AOU48RLAVM 4 tons · Condensing Unit ×3
AOUA120RLBV1 10 tons · Heat Pump Outdoor ×3
AOUA72RLBV1 6 tons · Heat Pump Outdoor ×3
AOUA96RLBV1 8 tons · Heat Pump Outdoor ×3
Heating
Fujitsu AOU36RLAVM 3 tons · Condensing Unit ×3
AOU48RLAVM 4 tons · Condensing Unit ×3
AOUA12RLBV1 10 tons · Condensing Unit ×3
AOUA72RLBV1 6 tons · Condensing Unit ×3
AOUA96RLBV1 8 tons · Condensing Unit ×3
Ventilation
Fujitsu ARUH72TLAV1 6 tons · Vrf Outdoor ×3
ARUH96TLAV 8 tons · Vrf Outdoor ×3
4 jobs · most recent 04/02/2025
Sprinkler System
FiledStatusContractorScope
04/02/2025Permit IssuedTHOMAS FAYSprinkler System
12/19/2024Signed-offAVON PLBG & HTG INCSprinkler System
07/22/2024Signed-offTHOMAS FAYSprinkler System
02/13/2023——Sprinkler System
4 jobs · most recent 06/25/2026
Water/Sanitary Gas
FiledStatusContractorScope
06/25/2026Permit IssuedXH&RC PLBG AND HTG INCGas, Water/Sanitary
04/02/2025Permit IssuedJ.A. MECH. PLBG. & HTG INWater/Sanitary
12/19/2024Permit IssuedI DO PLUMBING & HTG INCGas, Water/Sanitary
07/22/2024Permit IssuedJ.A. MECH. PLBG. & HTG INGas, Water/Sanitary
6 jobs · most recent 10/10/2025
General Wiring
FiledStatusContractorScope
10/10/2025CompleteGOODALL ELECTRIC CORPGeneral Wiring
09/18/2025Permit IssuedBIG SHOT ELECTRIC CORP.General Wiring
03/13/2024CompleteJONG HYUN KIM—
12/15/2023Permit IssuedJ Y ELECTRIC INCGeneral Wiring
05/12/2021CompleteTOP SHELF ELECTRIC CORP—
04/11/2019CompleteSCHWARTZ ELEC. CONTR'S INGeneral Wiring
2 jobs · most recent 06/25/2026
Steel Concrete
FiledStatusContractorScope
06/25/2026Permit IssuedXH&RC PLBG AND HTG INCSteel
10/04/2024Permit IssuedK & I CONTRACTING LLCSteel, Concrete
Building Lifecycle
All (249)Filed (59)Permit Issued (38)Signed Off (17)Violation (4)Inspection (24)Objection (77)Special Inspection (30)
07/15/2026
Objection raised — Other
07/15/2026
Objection raised — Cost
06/25/2026
Filed — Alteration
FILE PLUMBING WORK TO INSTALL NEW BATHROOM AND KITCHEN EQUIPMENT FOR FIRST FLOOR RESTAURANT AND INSTALL HOT WATER HEATER ON CELLAR. NO CHANGE OF USE, EGRESS OR OCCUPANCY.
M00952660-P6
02/09/2026
Objection raised — Cost
01/19/2026
Objection resolved — Resolved
01/19/2026
Objection resolved — Resolved
01/19/2026
Objection resolved — Resolved
01/19/2026
Objection resolved — Resolved
10/16/2025
Permit issued — Structural
M01098919-I1-ST
10/16/2025
Permit issued — General Construction
M01163111-I1-GC
10/09/2025
Special inspection requirement — Insulation placement and R values
EDUARD GRINFELD
10/09/2025
Special inspection requirement — Fire-Resistant Penetrations and Joints
EDUARD GRINFELD
10/09/2025
Special inspection requirement — Structural Cold-Formed Steel
EDUARD GRINFELD
10/09/2025
Special inspection requirement — Structural Steel - Details
EDUARD GRINFELD
10/09/2025
Special inspection requirement — Final
BENJAMIN SASSON
10/09/2025
Special inspection requirement — Lighting controls
EDUARD GRINFELD
10/09/2025
Special inspection requirement — Structural Stability – Alterations of existing buildings
EDUARD GRINFELD
10/09/2025
Special inspection requirement — Energy Code Compliance Inspections
EDUARD GRINFELD
10/09/2025
Special inspection requirement — Fire-Resistance Rated Construction
EDUARD GRINFELD
10/09/2025
Special inspection requirement — Mechanical Systems
EDUARD GRINFELD
10/09/2025
Special inspection requirement — Interior lighting power
EDUARD GRINFELD
10/09/2025
Special inspection requirement — Duct leakage testing, insulation and design
EDUARD GRINFELD
10/07/2025
Permit issued — Structural
M01098919-I1-ST
07/15/2025
Permit issued — Sprinklers
M01163111-S2-EW-SP
06/18/2025
Signed off — Alteration
PLUMBING WORK IN CONJUNCTION WITH THE INTERIOR RENOVATION OF THE 3RD FLOOR TENANT SPACE. NO CHANGE IN USE, EGRESS OR OCCUPANCY
M01109742-S2
06/13/2025
Special inspection requirement — Final
Stephen Shishko
06/13/2025
Special inspection requirement — Mechanical Systems
Stephen Shishko
06/13/2025
Special inspection requirement — Duct leakage testing, insulation and design
Stephen Shishko
06/13/2025
Special inspection requirement — HVAC-R and service water heating equipment
Stephen Shishko
06/13/2025
Special inspection requirement — Maintenance information
Stephen Shishko
06/13/2025
Special inspection requirement — Energy Code Compliance Inspections
Stephen Shishko
06/13/2025
Special inspection requirement — HVAC-R and service water piping design and insulation
Stephen Shishko
06/13/2025
Special inspection requirement — HVAC-R and service water heating system controls
Stephen Shishko
05/16/2025
Inspection — Fail-Final General Construction Non-Directive 14
Fail
View inspection ↗
05/09/2025
Objection resolved — Addressed
05/08/2025
Objection raised — Scope
05/08/2025
Objection resolved — Addressed
04/30/2025
Special inspection requirement — Insulation placement and R values
EDUARD GRINFELD
04/30/2025
Special inspection requirement — Lighting controls
EDUARD GRINFELD
04/30/2025
Special inspection requirement — Interior lighting power
EDUARD GRINFELD
04/30/2025
Special inspection requirement — Energy Code Compliance Inspections
EDUARD GRINFELD
04/30/2025
Special inspection requirement — Final
BENJAMIN SASSON
04/30/2025
Special inspection requirement — Duct leakage testing, insulation and design
EDUARD GRINFELD
04/30/2025
Special inspection requirement — Structural Stability – Alterations of existing buildings
EDUARD GRINFELD
04/30/2025
Special inspection requirement — Mechanical Systems
EDUARD GRINFELD
04/30/2025
Special inspection requirement — Structural Cold-Formed Steel
EDUARD GRINFELD
04/30/2025
Special inspection requirement — Structural Steel - Details
EDUARD GRINFELD
04/28/2025
Objection raised — Scope
04/25/2025
Permit issued — Plumbing
M01163111-S1-PL
04/23/2025
Filed — Alteration
PLUMBING WORK IN CONJUNCTION WITH THE INTERIOR RENOVATION OF THE 3RD FLOOR TENANT SPACE. NO CHANGE IN USE, EGRESS OR OCCUPANCY
M01109742-P2
04/23/2025
Signed off — Alteration
PLUMBING WORK IN CONJUNCTION WITH THE INTERIOR RENOVATION OF THE 3RD FLOOR TENANT SPACE. NO CHANGE IN USE, EGRESS OR OCCUPANCY
M01109742-S1
04/19/2025
Filed — Alteration
INSTALLATION OF AN ILLUMINATED BUSINESS ACCESSORY SIGN . NO CHANGE IN USE, EGRESS OR OCCUPANCY.
M01145816-I1
04/17/2025
Objection resolved — Addressed
04/16/2025
Signed off — Alteration
PLUMBING WORK IN CONJUNCTION WITH THE INTERIOR RENOVATION OF THE 3RD FLOOR TENANT SPACE. NO CHANGE IN USE, EGRESS OR OCCUPANCY
M01109742-I1
04/14/2025
Inspection — Certified Water and Sanitary-WS-Fixtures-Finish
Certified
View inspection ↗
04/14/2025
Objection raised — Scope
04/08/2025
Objection resolved — Addressed
04/08/2025
Objection resolved — Addressed
04/02/2025
Filed — Alteration
THE PROJECT CONSISTS OF PLUMBING WORK IN CONJUNCTION WITH THEINTERIOR RENOVATION AS PER PLANS FILED HEREWITH. NO CHANGE IN USE,EGRESS OR OCCUPANCY.
M01163111-S1
04/02/2025
Filed — Alteration
THE PROJECT CONSISTS OF PLUMBING WORK IN CONJUNCTION WITH THEINTERIOR RENOVATION AS PER PLANS FILED HEREWITH. NO CHANGE IN USE,EGRESS OR OCCUPANCY.
M01163111-S2
Latest 60 of 249 events.
▾Owner History (Filing Record)
Companies and organizations named on filings. Individual owners are not shown.
OwnerFilingsMost Recent
RABER ENTERPRISES603/21/2026
ORIENTAL GARDEN RESTAURANT403/21/2026
STADIUM OFFICE DEVELOPMENT503/21/2026
▾Design Consultants (Architect / Engineer of Record)
▾Filing Representatives (Expediters)
RepresentativeFilingsMost Recent
UNITED SAFETY CONSULTANTS203/21/2026
CODE6203/21/2026
MUNICIPAL BUILDING CONSULTANTS103/21/2026
MYLES ARCHITECTURE P C1203/21/2026
ARSENAL BUILDING CONSULTANTS LLC403/21/2026
▾Contractors (License-Anchored)
FirmTradeRolesMost Recent
WECUSTOM INCGeneral Contractor807/08/2026
SPRING SCAFFOLDING LLCGeneral Contractor607/08/2026
WEBUILD INCGeneral Contractor607/08/2026
K & I CONTRACTING LLCGeneral Contractor407/08/2026
J.A. MECH. PLBG. & HTG INPlumbing407/08/2026
A.A. MECHANICAL SOL INCGeneral Contractor307/08/2026
ANESIS SERVICES CORPFire Protection307/08/2026
AVON PLBG & HTG INCFire Protection207/08/2026
BEYOND BUILDING INCGeneral Contractor203/21/2026
EUROSTRUCT INCGeneral Contractor203/21/2026
JD ARCH LLCGeneral Contractor203/21/2026
XH&RC PLBG AND HTG INCPlumbing107/08/2026
THOMAS FAYFire Protection103/21/2026
URBAN INTELLIGENCE, INCGeneral Contractor107/08/2026
AVON PLBG & HTG INCPlumbing107/08/2026
CROSSFIELD PLBG.&HTGPlumbing107/08/2026
DYNAMIC BLUE WATER MECHPlumbing107/08/2026
I DO PLUMBING & HTG INCPlumbing107/08/2026
ERNEST JOCHENElectrical103/21/2026
▾Special Inspection Agencies
AgencyLicense #FilingsMost Recent
CMSC, INC6098706/25/2026
NEW AGE ENGINEERING PLLC7746304/23/2025
AK ENGINEERING PC678204/02/2025
LCW ENGINEERING, PC11031312/27/2024
CHEN ENGINEERING SERVICES1826309/26/2024
MYLES ARCHITECTURE, P.C.29381007/22/2024
Permit / Filing Register
SourceWork TypeStatusApplicantIssued
DOB NOWStructuralPermit IssuedK I CONTRACTING10/16/2025
DOB NOWGeneral ConstructionPermit IssuedK I CONTRACTING10/16/2025
DOB NOWStructuralPermit IssuedK I CONTRACTING10/07/2025
DOB NOWSprinklersPermit IssuedTHOMAS FAY07/15/2025
DOB NOWPlumbingPermit IssuedJ.A. MECH. PLBG. & HTG IN04/25/2025
DOB NOWGeneral ConstructionPermit IssuedK I CONTRACTING03/31/2025
DOB NOWMechanical SystemsSigned-offA.A. MECHANICAL SOL INC03/03/2025
DOB NOWPlumbingSigned-offSUPER PLUMBERS CORP02/24/2025
DOB NOWPlumbingSigned-offJ.A. MECH. PLBG. & HTG IN01/13/2025
DOB NOWGeneral ConstructionSigned-offEUROSTRUCT INC11/27/2024
DOB NOWMechanical SystemsSigned-offA.A. MECHANICAL SOL INC11/15/2024
DOB NOWPlumbingSigned-offTHOMAS FAY07/09/2024
DOB NOWPlumbingPermit IssuedJ.A. MECH. PLBG. & HTG IN06/27/2024
DOB NOWPlumbingPermit IssuedXH&RC PLBG AND HTG INC02/16/2024
DOB NOWGeneral ConstructionPermit IssuedJD ARCH LLC02/06/2024
DOB NOWSprinklersSigned-offTHOMAS FAY01/30/2024
DOB NOWPlumbingPermit IssuedCROSSFIELD PLBG.&HTG11/27/2023
DOB NOWStructuralPermit IssuedBEYOND BUILDING INC11/09/2023
DOB NOWStructuralSigned-offWECUSTOM INC11/08/2023
DOB NOWPlumbingSigned-offJ.A. MECH. PLBG. & HTG IN10/10/2023
DOB NOWMechanical SystemsSigned-offA.A. MECHANICAL SOL INC09/29/2023
DOB NOWGeneral ConstructionSigned-offURBAN INTELLIGENCE, INC09/13/2023
DOB NOWGeneral ConstructionSigned-offWECUSTOM INC06/21/2023
DOB NOWConstruction FenceSigned-offWECUSTOM INC06/05/2023
DOB NOWGeneral ConstructionSigned-offWECUSTOM INC06/02/2023
DOB NOWMechanical SystemsPermit IssuedWECUSTOM INC03/28/2023
DOB NOWSprinklersSigned-offAVON PLBG & HTG INC03/21/2023
DOB NOWPlumbingPermit IssuedI DO PLUMBING & HTG INC03/03/2023
DOB NOWGeneral ConstructionPermit IssuedWECUSTOM INC01/23/2023
DOB NOWSidewalk ShedSigned-offSPRING SCAFFOLDING LLC04/12/2022
DOB NOWSprinklersSigned-offAVON PLBG & HTG INC01/31/2022
DOB NOWPlumbingPermit IssuedAVON PLBG & HTG INC01/31/2022
DOB NOWGeneral ConstructionPermit IssuedWEBUILD01/19/2022
DOB NOWMechanical SystemsPermit IssuedWEBUILD01/13/2022
DOB NOWGeneral ConstructionPermit IssuedWEBUILD07/07/2021
DOB NOWConstruction FenceSigned-offWEBUILD05/13/2021
DOB NOWSupported ScaffoldSigned-offSPRING SCAFFOLDING LLC05/12/2021
DOB NOWSidewalk ShedSigned-offSPRING SCAFFOLDING LLC05/12/2021
BISFPISSUEDNY FIRETECH INC11/29/2017
BISPLISSUEDAAA TOTAL PLUMBING, INC09/08/2017
+ 26 more permits on file
▾Field Inspections (DOB CAP) — 24
DateTypeResultReport
05/16/2025Fail-Final General Construction Non-Directive 14FailView ↗
04/14/2025Certified Water and Sanitary-WS-Fixtures-FinishCertifiedView ↗
02/28/2025Certified Water and Sanitary-WS-Sanitary Piping-RoughingCertifiedView ↗
11/25/2024Pass-Final CND-Occupancy InspectionPassView ↗
09/09/2024Certified Sprinkler-SP-Fixtures-FinishCertifiedView ↗
09/05/2024Certified Sprinkler-SP-Piping Dry/Wet-Hydrostatic TestCertifiedView ↗
06/28/2024Certified Sprinkler-SP-Fixtures-FinishCertifiedView ↗
06/26/2024Certified Sprinkler-SP-Piping Dry/Wet-Hydrostatic TestCertifiedView ↗
06/12/2024Pass-Final PL - Up to 3 Requested FloorsPassView ↗
03/25/2024Certified Gas-Gas-Piping-RoughingCertifiedView ↗
03/25/2024Certified Water and Sanitary-WS-Sanitary Piping-RoughingCertifiedView ↗
01/08/2024Pass-Final PL - Up to 3 Requested FloorsPassView ↗
12/27/2023Pass-Final PL - UndergroundPassView ↗
11/01/2023Pass-Final PL - Up to 3 Requested FloorsPassView ↗
10/25/2023Fail-Final PL - Up to 3 Requested FloorsFailView ↗
10/19/2023Pass-Final PL - Up to 3 Requested FloorsPassView ↗
09/27/2023Certified Sprinkler-SP-Piping Dry/Wet-Hydrostatic TestCertifiedView ↗
09/26/2023Certified Sprinkler-SP-Fixtures-FinishCertifiedView ↗
06/29/2023Pass-Final PL - Up to 3 Requested FloorsPassView ↗
05/30/2023Pass-Final CND-Occupancy InspectionPassView ↗
03/31/2023Certified Water and Sanitary-WS-Sanitary Piping-RoughingCertifiedView ↗
03/31/2023Certified Water and Sanitary-WS-Sanitary Piping-UndergroundCertifiedView ↗
02/04/2022Certified Water and Sanitary-WS-Sanitary Piping-RoughingCertifiedView ↗
02/04/2022Certified Water and Sanitary-WS-Sanitary Piping-UndergroundCertifiedView ↗
▾Special Inspection Requirements (DOB NOW) — 150
DateRequirementInspectorRole
10/09/2025Fire-Resistant Penetrations and JointsEDUARD GRINFELDspecial
10/09/2025Lighting controlsEDUARD GRINFELDenergy_progress
10/09/2025Interior lighting powerEDUARD GRINFELDenergy_progress
10/09/2025Insulation placement and R valuesEDUARD GRINFELDenergy_progress
10/09/2025Duct leakage testing, insulation and designEDUARD GRINFELDenergy_progress
10/09/2025Fire-Resistance Rated ConstructionEDUARD GRINFELDprogress
10/09/2025FinalBENJAMIN SASSONprogress
10/09/2025Energy Code Compliance InspectionsEDUARD GRINFELDprogress
10/09/2025Structural Steel - DetailsEDUARD GRINFELDspecial
10/09/2025Structural Stability – Alterations of existing buildingsEDUARD GRINFELDspecial
10/09/2025Structural Cold-Formed SteelEDUARD GRINFELDspecial
10/09/2025Mechanical SystemsEDUARD GRINFELDspecial
06/13/2025Mechanical SystemsStephen Shishkospecial
06/13/2025Energy Code Compliance InspectionsStephen Shishkoprogress
06/13/2025FinalStephen Shishkoprogress
06/13/2025Maintenance informationStephen Shishkoenergy_progress
06/13/2025HVAC-R and service water heating equipmentStephen Shishkoenergy_progress
06/13/2025HVAC-R and service water piping design and insulationStephen Shishkoenergy_progress
06/13/2025Duct leakage testing, insulation and designStephen Shishkoenergy_progress
06/13/2025HVAC-R and service water heating system controlsStephen Shishkoenergy_progress
04/30/2025Duct leakage testing, insulation and designEDUARD GRINFELDenergy_progress
04/30/2025Interior lighting powerEDUARD GRINFELDenergy_progress
04/30/2025Insulation placement and R valuesEDUARD GRINFELDenergy_progress
04/30/2025Fire-Resistant Penetrations and JointsEDUARD GRINFELDspecial
04/30/2025Mechanical SystemsEDUARD GRINFELDspecial
Latest 25 of 150.
▾Documents — 482 on file (BIS + DOB NOW)
▸Plans & Drawings58
▸DOB NOWPlans/Sketch56
09/03/2026M00511874-I1Request digital key ↗
09/03/2026M00511862-I1Request digital key ↗
09/03/2026M00519688-I1Request digital key ↗
Showing 3 of 56 on file for this type
▸DOB NOWPlans/Sketch - Temporary Place of Assembly2
08/31/2026M00817463-I1Request digital key ↗
08/29/2026M00928795-I1Request digital key ↗
▸Applications & Permits47
▸BISPLAN / WORK APPROVAL APPLICATION29
02/12/2025101106811Open ↗
02/12/2025101543215Open ↗
02/12/2025103154667Open ↗
Showing 3 of 29 on file for this type
▸BISWORK PERMIT APPLICATION14
11/29/2017123343970Open ↗
09/11/2017123120096Open ↗
09/11/2017123120096Open ↗
Showing 3 of 14 on file for this type
▸BISPLACE OF ASSEMBLY3
10/15/2013121109282Open ↗
06/12/2012121109282Open ↗
09/22/2010120346580Open ↗
▸BISPLACE OF ASSEMBLY APPLICATION1
02/26/2014121109282Open ↗
▸Zoning, Tax Lot & Property Records2
▸DOB NOWRestrictive Declaration/Easement 12
On file, but not among the 200 most recently loaded documents for this source.
Showing 0 of 2 on file for this type
▸Seals & Professional Certifications211
▸DOB NOWProgress Inspector Seal & Signature77
09/02/2026M00881653-S2Open ↗
09/02/2026M00881653-S2Open ↗
09/02/2026M00881653-S2Open ↗
Showing 3 of 77 on file for this type
▸DOB NOWDPL-1: Design Professional Seal & Signature58
09/03/2026M00511874-I1Open ↗
09/02/2026M00586765-S2Open ↗
09/02/2026M00586765-P2Open ↗
Showing 3 of 58 on file for this type
▸DOB NOWSpecial Inspector Seal & Signature37
09/02/2026M00881653-S2Open ↗
09/02/2026M00952660-I1Open ↗
09/02/2026M00952660-I1Open ↗
Showing 3 of 37 on file for this type
▸BISTECHNICAL REPORT: RESPONSIBILITY/CERTIFICATION21
02/21/2018123120096Open ↗
11/09/2017123343970Open ↗
09/08/2017123120096Open ↗
Showing 3 of 21 on file for this type
▸BISPROFESSIONAL CERTIFICATION STATEMENT FORM8
04/03/2012121008079Open ↗
04/03/2012121008079Open ↗
04/03/2012121008079Open ↗
Showing 3 of 8 on file for this type
▸BISPROFESSIONAL CERTIFIED CHECKLIST6
11/09/2017123343970Open ↗
09/27/2016140542679Open ↗
04/03/2012121008079Open ↗
Showing 3 of 6 on file for this type
▸BISPROFESSIONAL CERTIFICATION STATEMENT2
11/09/2017123343970Open ↗
08/30/2016140542679Open ↗
▸BISREQUIRED ITEMS CHECKLIST FOR PROFESSIONAL CERTIFICATION1
08/30/2016140542679Open ↗
▸BISTECHNICAL REPORT STATEMENT OF RESPONSIBILITY1
08/30/2016140542679Open ↗
▸Trade Schedules & Equipment21
▸BISSCHEDULE B - PLUMBING8
01/29/2013121008079Open ↗
01/17/2013121008079Open ↗
11/05/2012121008079Open ↗
Showing 3 of 8 on file for this type
▸BISSCHEDULE B - PLUMBING/SPRINKLER/STANDPIPE6
12/01/2017123120096Open ↗
11/24/2017123120096Open ↗
10/04/2017123120096Open ↗
Showing 3 of 6 on file for this type
▸BISSELF-CERT PLUMBING NOTICE4
04/04/2014121008079Open ↗
03/25/2013121008079Open ↗
01/25/2010120103262Open ↗
Showing 3 of 4 on file for this type
▸BISEQUIPMENT USE APPLICATION/PERMIT1
10/17/2016140542679Open ↗
▸BISEQUIPMENT USE PERMITS1
10/17/2016140542679Open ↗
▸BISFA - FDNY APPROVAL : FD-FAA1
05/22/2018123343970Open ↗
▸Safety & Tenant Protection4
▸BISTENANT PROTECTION PLAN AND NOTES2
08/30/2016140542679Open ↗
08/23/2017123120096Open ↗
▸BISST-1: Street Tree Checklist2
07/10/2008110239420Open ↗
04/03/2012121008079Open ↗
▸Environmental & Asbestos60
▸DOB NOWDEP ACP-5: Asbestos Assessment Report48
09/02/2026M00586765-P3Open ↗
09/02/2026M00586765-S1Open ↗
09/02/2026M00586765-S2Open ↗
Showing 3 of 48 on file for this type
▸BISASBESTOS: CERTIFICATION (DEP ACP5)4
08/23/2017123120096Open ↗
08/30/2016140542679Open ↗
08/17/2012121346178Open ↗
Showing 3 of 4 on file for this type
▸BISTHIS IS 'NOT AN ASBESTOS PROJECT'4
04/03/2012121008079Open ↗
07/13/2009120103262Open ↗
07/10/2009120102129Open ↗
Showing 3 of 4 on file for this type
▸BISASBESTOS EXEMPTION CERTIFICATION LETTER3
09/22/2010120346580Open ↗
09/22/2010120346580Open ↗
07/10/2008110239420Open ↗
▸BISACP5 ASBESTOS: CERTIFICATION (DEP ACP5)1
03/11/2014121917293Open ↗
▸Energy Compliance14
▸BISTECHNICAL REPORT: ENERGY CODE PROGRESS INSPS7
02/21/2018123120096Open ↗
09/08/2017123120096Open ↗
08/23/2017123120096Open ↗
Showing 3 of 7 on file for this type
▸BISAS-BUILT ENERGY ANALYSIS3
02/21/2018123120096Open ↗
10/24/2016140542679Open ↗
03/14/2016121917293Open ↗
▸BISTECHNICAL REPORT: ENERGY2
04/06/2012121008079Open ↗
04/03/2012121008079Open ↗
▸BISTECHNICAL REPORT STATEMENT OF RESPONSIBILITY FOR ENERGY CODE PROGRESS INSPECTIONS1
08/30/2016140542679Open ↗
▸BISTECHNICAL REPORT: ENERGY CODE - RESPONSIBILITY1
08/30/2016140542679Open ↗
▸Inspections & Test Reports1
▸BISTECHNICAL REPORT: RESPONSIBILITY1
08/30/2016140542679Open ↗
▸Approvals, Objections & Sign-offs15
▸BISADMINISTRATIVE OBJECTIONS8
08/17/2012121346178Open ↗
07/30/2012121164907Open ↗
06/12/2012121109282Open ↗
Showing 3 of 8 on file for this type
▸BISCERTIFICATE OF OCCUPANCY/LOC: REQUEST6
09/25/2024102832721Open ↗
05/22/2018123343970Open ↗
02/21/2018123120096Open ↗
Showing 3 of 6 on file for this type
▸BISLETTERS - SUPPORTING DOCUMENTATION1
02/26/2014121109282Open ↗
▸Cost, Insurance & Ownership16
▸BISCOST AFFIDAVIT16
05/22/2018123343970Open ↗
02/21/2018123120096Open ↗
11/09/2017123343970Open ↗
Showing 3 of 16 on file for this type
▸Filing & Intake Forms25
▸BISADDITIONAL INFORMATION11
12/05/2017123120096Open ↗
11/13/2017123120096Open ↗
02/03/2016121917293Open ↗
Showing 3 of 11 on file for this type
▸BISEFILING COVER SHEET8
11/09/2017123343970Open ↗
08/23/2017123120096Open ↗
02/10/2014121917293Open ↗
Showing 3 of 8 on file for this type
▸BISBOROUGH INTAKE FORM4
05/22/2018123343970Open ↗
02/21/2018123120096Open ↗
11/24/2017123120096Open ↗
Showing 3 of 4 on file for this type
▸BISEFILING JOB APPLICATION COVER SHEET2
08/30/2016140542679Open ↗
07/10/2008110239420Open ↗
▸Other Documents8
▸BISCONSTRUCTION - SUPPORTING DOCUMENTATION5
02/12/2025101106811Open ↗
02/12/2025101543215Open ↗
02/12/2025103154667Open ↗
Showing 3 of 5 on file for this type
▸BISEXTERNAL FORMS - SUPPORTING DOCUMENTATION2
11/30/2017123343970Open ↗
03/14/2016121917293Open ↗
▸DOB NOWPARTIAL DEMO: 10-DAY Notice1
On file, but not among the 200 most recently loaded documents for this source.
Showing 0 of 1 on file for this type