← Back
Two family converted from one family
460 5 STREET
BROOKLYN · BIN 3021500
💬 Discuss this project
1901Year Built
3Stories
B3Building Class
R6BZoning
3,672 sfGross Floor Area
2Units
0 Open ViolationsFDNY Report ↗
Two family converted from one family · 2,000 sf lot · 1.84 FAR built · Flood zone X
Locations of Work
Architecture
Permit Issued — active, not yet Signed-off
Floor 2Under Construction1p · 1 filing · 19 docs
Floor 1Under Construction1p · 1 filing · 19 docs
▾Sales History (ACRIS)
DatePriceUnitSeller → Buyer$/sf
11/19/2025$5.0M—Private party → Private party$1,362/sf building
▾Design Consultants (Architect / Engineer of Record)
FirmFilingsMost Recent
JONATHAN OTT208/25/2026
JON PAUL DESIGN & CONSULTING102/27/2026
▾Filing Representatives (Expediters)
RepresentativeFilingsMost Recent
JON PAUL DESIGN & CONSULTING203/21/2026
VRD DEVELOPMENT203/21/2026
▾Contractors (License-Anchored)
FirmTradeRolesMost Recent
DIPIERRO ACTION CONSTR COGeneral Contractor107/30/2026
▾Special Inspection Agencies
AgencyLicense #FilingsMost Recent
CONSULTING ENGINEER5093202/27/2026
Building Lifecycle
All (27)Filed (3)Permit Issued (1)Violation (2)Objection (6)Special Inspection (15)
08/25/2026
Filed — Alteration
GC WORK TYPE FOR MINOR PARTITIONS & COSMETIC FINISHES AT 1 FLOOR & ERECT BALCONY W/ NEW DOOR AT 2 FLOOR REAR AS PER PLANS SUBMITTED HEREWITH. ST FILED SEPARATELY BY OTHERS. NO CHANGE TO EGRESS, USE OR OCCUPANCY.
B01342278-S2
08/25/2026
Special inspection requirement — Energy Code Compliance Inspections
08/25/2026
Special inspection requirement — Fire-Resistant Penetrations and Joints
07/29/2026
Permit issued — General Construction
B01342278-I1-GC
02/27/2026
Filed — Alteration
GC WORK TYPE FOR MINOR PARTITIONS & COSMETIC FINISHES AT 1 FLOOR & ERECT BALCONY W/ NEW DOOR AT 2 FLOOR REAR AS PER PLANS SUBMITTED HEREWITH. ST FILED SEPARATELY BY OTHERS. NO CHANGE TO EGRESS, USE OR OCCUPANCY.
B01342278-S1
02/05/2026
Objection resolved — Addressed
02/05/2026
Objection resolved — Addressed
02/05/2026
Objection resolved — Addressed
02/04/2026
Objection raised — Inspections
02/04/2026
Objection raised — Zoning
02/04/2026
Objection raised — Structural
01/26/2026
Filed — Alteration
GC WORK TYPE FOR MINOR PARTITIONS & COSMETIC FINISHES AT 1 FLOOR & ERECT BALCONY W/ NEW DOOR AT 2 FLOOR REAR AS PER PLANS SUBMITTED HEREWITH. ST FILED SEPARATELY BY OTHERS. NO CHANGE TO EGRESS, USE OR OCCUPANCY.
B01342278-I1
01/23/2026
Special inspection requirement — Lighting in dwelling units
John Natoli
01/23/2026
Special inspection requirement — Air barrier - visual inspection
John Natoli
01/16/2026
Special inspection requirement — Structural Steel - Details
John Natoli
01/16/2026
Special inspection requirement — Structural Stability – Alterations of existing buildings
John Natoli
01/06/2026
Special inspection requirement — Interior lighting power
John Natoli
01/06/2026
Special inspection requirement — Insulation placement and R values
John Natoli
01/06/2026
Special inspection requirement — Fenestration and door U-factor and product ratings
John Natoli
01/06/2026
Special inspection requirement — Final
John Natoli
01/06/2026
Special inspection requirement — Fire-Resistant Penetrations and Joints
John Natoli
01/06/2026
Special inspection requirement — Energy Code Compliance Inspections
John Natoli
01/06/2026
Special inspection requirement — Fire-Resistance Rated Construction
John Natoli
01/06/2026
Special inspection requirement — Fenestration air leakage
John Natoli
01/06/2026
Special inspection requirement — Fenestration areas
John Natoli
03/24/2004
Violation issued (DOB, closed)
V*-DOB VIOLATION - DISMISSED
02/20/2004
Violation issued (ECB, closed)
Construction
Permit / Filing Register
SourceWork TypeStatusApplicantIssued
DOB NOWGeneral ConstructionPermit IssuedDIPIERRO ACTION CONSTR CO07/29/2026
BISMHISSUEDSQUARE INDIGO INC04/12/2005
BISPLISSUEDR.J.C. MECHANICAL CORP04/19/2004
BISOTISSUEDPATRICK DEAN CONST MGMT04/01/2004
BISOTISSUEDPATRICK DEAN CONST MGMT04/01/2004
BISPLISSUEDPP COUSIN INC03/10/2004
BISOTISSUEDBOWMAN CONSTRUCTION CORP06/17/2003
BISOTISSUEDBOWMAN CONSTRUCTION CORP06/17/2003
Nothing on file for this building.
▾Special Inspection Requirements (DOB NOW) — 15
DateRequirementInspectorRole
08/25/2026Energy Code Compliance Inspections—progress
08/25/2026Fire-Resistant Penetrations and Joints—special
01/23/2026Lighting in dwelling unitsJohn Natolienergy_progress
01/23/2026Air barrier - visual inspectionJohn Natolienergy_progress
01/16/2026Structural Steel - DetailsJohn Natolispecial
01/16/2026Structural Stability – Alterations of existing buildingsJohn Natolispecial
01/06/2026Interior lighting powerJohn Natolienergy_progress
01/06/2026Insulation placement and R valuesJohn Natolienergy_progress
01/06/2026Fenestration and door U-factor and product ratingsJohn Natolienergy_progress
01/06/2026FinalJohn Natoliprogress
01/06/2026Fire-Resistant Penetrations and JointsJohn Natolispecial
01/06/2026Energy Code Compliance InspectionsJohn Natoliprogress
01/06/2026Fire-Resistance Rated ConstructionJohn Natoliprogress
01/06/2026Fenestration air leakageJohn Natolienergy_progress
01/06/2026Fenestration areasJohn Natolienergy_progress
▾Documents — 19 on file (BIS + DOB NOW)
▸Plans & Drawings2
▸DOB NOWPlans/Sketch2
08/18/2026B01342278-I1Request digital key ↗
08/18/2026B01342278-S1Request digital key ↗
▸Seals & Professional Certifications15
▸DOB NOWProgress Inspector Seal & Signature10
09/01/2026B01342278-I1Open ↗
09/01/2026B01342278-I1Open ↗
09/01/2026B01342278-I1Open ↗
Showing 3 of 10 on file for this type
▸DOB NOWSpecial Inspector Seal & Signature3
09/01/2026B01342278-I1Open ↗
08/27/2026B01342278-S1Open ↗
08/27/2026B01342278-S1Open ↗
▸DOB NOWDPL-1: Design Professional Seal & Signature2
08/13/2026B01342278-S1Open ↗
08/13/2026B01342278-I1Open ↗
▸Environmental & Asbestos2
▸DOB NOWDEP ACP-5: Asbestos Assessment Report2
08/13/2026B01342278-S1Open ↗
08/13/2026B01342278-I1Open ↗