← Back
Two family brick
460 EAST 183 STREET
BRONX · Belmont · BIN 2011337
💬 Discuss this project
1910Year Built
2Stories
B1Building Class
R6AZoning
1,536 sfGross Floor Area
2Units
Rent Stabilized4 Open Violations ▸
Two family brick · 1,485 sf lot · 1.03 FAR built · Flood zone X
Locations of Work
MechanicalPlumbing
Roof1p · 1 filing · 20 docs
Floor 215p · 2 filings · 20 docs
Floor 114p · 2 filings · 20 docs
Cellar14p · 2 filings · 20 docs
Sub-Basement14p · 2 filings · 20 docs
▾Owner History (Filing Record)
Companies and organizations named on filings. Individual owners are not shown.
OwnerFilingsMost Recent
SAFEGUARD HOMES LLC SAFEGUARD CRED1807/08/2026
▾Sales History (ACRIS)
DatePriceUnitSeller → Buyer$/sf
12/22/2022$710K—SAFEGUARD HOMES II LLC → Private party$462/sf building
05/16/2019$300K—U. S. BANK NATIONAL ASSOCIATION → SAFEGUARD HOMES II LLC$195/sf building
07/30/2018$402K—— → —$262/sf building
▾Design Consultants (Architect / Engineer of Record)
FirmFilingsMost Recent
BADALY ENGINEERING PLLC601/06/2023
▾Contractors (License-Anchored)
FirmTradeRolesMost Recent
TAP PLUMBING CORPPlumbing907/08/2026
HOLNESS, GEORGEElectrical203/21/2026
TRANSCANADAElectrical203/21/2026
2260 MAG CORPGeneral Contractor107/08/2026
MAMC CONSULTING REPS LLCGeneral Contractor107/08/2026
▾Special Inspection Agencies
AgencyLicense #FilingsMost Recent
BADALY ARCHITECT PLLC7137601/06/2023
Building Lifecycle
All (103)Filed (6)Permit Issued (4)Signed Off (2)Violation (60)Inspection (5)Special Inspection (26)
11/24/2025
Violation issued (HPD, open)
I
12/03/2024
Violation issued (HPD, open)
I
11/27/2023
Violation issued (HPD, open)
I
03/02/2023
Signed off — Alteration
New ducted mechanical system as per plans filed.
X00504910-I1
02/17/2023
Signed off — Alteration
New gas service and plumbing fixtures as per plans filed.
X00504911-I1
01/11/2023
Special inspection requirement — Mechanical Systems
SHAHIN BADALY
01/11/2023
Special inspection requirement — Maintenance information
SHAHIN BADALY
01/11/2023
Special inspection requirement — HVAC-R and service water heating system controls
SHAHIN BADALY
01/11/2023
Special inspection requirement — HVAC-R and service water heating equipment
SHAHIN BADALY
01/11/2023
Special inspection requirement — HVAC-R and service water piping design and insulation
SHAHIN BADALY
01/11/2023
Special inspection requirement — Energy Code Compliance Inspections
SHAHIN BADALY
01/11/2023
Special inspection requirement — Final
SHAHIN BADALY
01/11/2023
Special inspection requirement — Fire-Resistant Penetrations and Joints
SHAHIN BADALY
01/06/2023
Filed — Alteration
New gas service and plumbing fixtures as per plans filed.
X00504911-P3
01/06/2023
Filed — Alteration
New ducted mechanical system as per plans filed.
X00504910-P1
12/21/2022
Special inspection requirement — HVAC-R and service water piping design and insulation
SHAHIN BADALY
12/21/2022
Special inspection requirement — Fire-Resistant Penetrations and Joints
SHAHIN BADALY
12/21/2022
Special inspection requirement — Mechanical Systems
SHAHIN BADALY
12/21/2022
Special inspection requirement — Energy Code Compliance Inspections
SHAHIN BADALY
12/21/2022
Special inspection requirement — Final
SHAHIN BADALY
12/21/2022
Special inspection requirement — HVAC-R and service water heating system controls
SHAHIN BADALY
12/21/2022
Special inspection requirement — HVAC-R and service water heating equipment
SHAHIN BADALY
12/21/2022
Special inspection requirement — Maintenance information
SHAHIN BADALY
12/12/2022
Special inspection requirement — Maintenance information
SHAHIN BADALY
12/12/2022
Special inspection requirement — HVAC-R and service water piping design and insulation
SHAHIN BADALY
12/12/2022
Special inspection requirement — Fire-Resistant Penetrations and Joints
SHAHIN BADALY
12/12/2022
Special inspection requirement — HVAC-R and service water heating equipment
SHAHIN BADALY
12/12/2022
Special inspection requirement — HVAC-R and service water heating system controls
SHAHIN BADALY
10/21/2022
Permit issued — Mechanical Systems
X00504910-I1-MS
09/20/2022
Violation issued (DOB, closed)
V*-DOB VIOLATION - DISMISSED
09/20/2022
Violation issued (DOB, closed)
V*-DOB VIOLATION - DISMISSED
09/14/2022
Permit issued — Plumbing
X00504911-I1-PL
07/14/2022
Filed — Alteration
New gas service and plumbing fixtures as per plans filed.
X00504911-P2
07/01/2022
Permit issued — Mechanical Systems
X00504910-I1-MS
10/12/2021
Inspection — Certified Gas-Gas-Piping-Roughing
Certified
View inspection ↗
10/05/2021
Inspection — Certified Storm Drainage-ST-Piping-Roughing
Certified
View inspection ↗
10/05/2021
Inspection — Certified Storm Drainage-ST-Piping-Underground
Certified
View inspection ↗
10/05/2021
Inspection — Certified Water and Sanitary-WS-Sanitary Piping-Roughing
Certified
View inspection ↗
10/05/2021
Inspection — Certified Water and Sanitary-WS-Sanitary Piping-Underground
Certified
View inspection ↗
09/08/2021
Permit issued — Plumbing
X00504911-I1-PL
07/09/2021
Filed — Alteration
New gas service and plumbing fixtures as per plans filed.
X00504911-P1
07/09/2021
Special inspection requirement — Maintenance information
SHAHIN BADALY
07/09/2021
Special inspection requirement — HVAC-R and service water piping design and insulation
SHAHIN BADALY
07/09/2021
Special inspection requirement — Fire-Resistant Penetrations and Joints
SHAHIN BADALY
07/09/2021
Special inspection requirement — HVAC-R and service water heating equipment
SHAHIN BADALY
07/09/2021
Special inspection requirement — HVAC-R and service water heating system controls
SHAHIN BADALY
04/27/2021
Filed — Alteration
New ducted mechanical system as per plans filed.
X00504910-I1
04/27/2021
Filed — Alteration
New gas service and plumbing fixtures as per plans filed.
X00504911-I1
04/21/2021
Violation issued (HPD, closed)
I
11/08/2019
Violation issued (HPD, closed)
I
01/11/2018
Violation issued (HPD, closed)
I
06/12/2013
Violation issued (ECB, closed)
Construction
04/30/2013
Violation issued (ECB, closed)
Construction
02/27/2013
Violation issued (DOB, closed)
V*-DOB VIOLATION - DISMISSED
02/11/2013
Violation issued (ECB, closed)
Construction
12/10/2012
Violation issued (DOB, closed)
V*-DOB VIOLATION - DISMISSED
12/06/2012
Violation issued (ECB, closed)
Construction
01/30/2012
Violation issued (ECB, closed)
Construction
11/15/2011
Violation issued (ECB, closed)
Construction
09/20/2011
Violation issued (ECB, closed)
Construction
Latest 60 of 103 events.
Permit / Filing Register
SourceWork TypeStatusApplicantIssued
DOB NOWMechanical SystemsSigned-offMAMC CONSULTING REPS LLC10/21/2022
DOB NOWPlumbingSigned-offTAP PLUMBING CORP09/14/2022
DOB NOWMechanical SystemsSigned-off2260 MAG CORP07/01/2022
DOB NOWPlumbingSigned-offTAP PLUMBING CORP09/08/2021
BISOTISSUEDMAMC CONSULTING REPS LLC11/29/2022
BISOTISSUED2260 MAG CORP10/22/2021
BISOTISSUED2260 MAG CORP01/13/2021
BISOTISSUED2260 MAG CORP09/23/2020
1 project · most recent 09/14/2022
General Wiring
FiledStatusContractorScope
09/14/2022CompleteL.D.M. ELECTL CONTRS INCGeneral Wiring
▾Field Inspections (DOB CAP) — 5
DateTypeResultReport
10/12/2021Certified Gas-Gas-Piping-RoughingCertifiedView ↗
10/05/2021Certified Storm Drainage-ST-Piping-RoughingCertifiedView ↗
10/05/2021Certified Storm Drainage-ST-Piping-UndergroundCertifiedView ↗
10/05/2021Certified Water and Sanitary-WS-Sanitary Piping-RoughingCertifiedView ↗
10/05/2021Certified Water and Sanitary-WS-Sanitary Piping-UndergroundCertifiedView ↗
▾Special Inspection Requirements (DOB NOW) — 26
DateRequirementInspectorRole
01/11/2023Mechanical SystemsSHAHIN BADALYspecial
01/11/2023Maintenance informationSHAHIN BADALYenergy_progress
01/11/2023HVAC-R and service water heating system controlsSHAHIN BADALYenergy_progress
01/11/2023HVAC-R and service water heating equipmentSHAHIN BADALYenergy_progress
01/11/2023HVAC-R and service water piping design and insulationSHAHIN BADALYenergy_progress
01/11/2023Energy Code Compliance InspectionsSHAHIN BADALYprogress
01/11/2023FinalSHAHIN BADALYprogress
01/11/2023Fire-Resistant Penetrations and JointsSHAHIN BADALYspecial
12/21/2022HVAC-R and service water piping design and insulationSHAHIN BADALYenergy_progress
12/21/2022Fire-Resistant Penetrations and JointsSHAHIN BADALYspecial
12/21/2022Mechanical SystemsSHAHIN BADALYspecial
12/21/2022Energy Code Compliance InspectionsSHAHIN BADALYprogress
12/21/2022FinalSHAHIN BADALYprogress
12/21/2022HVAC-R and service water heating system controlsSHAHIN BADALYenergy_progress
12/21/2022HVAC-R and service water heating equipmentSHAHIN BADALYenergy_progress
12/21/2022Maintenance informationSHAHIN BADALYenergy_progress
12/12/2022Maintenance informationSHAHIN BADALYenergy_progress
12/12/2022HVAC-R and service water piping design and insulationSHAHIN BADALYenergy_progress
12/12/2022Fire-Resistant Penetrations and JointsSHAHIN BADALYspecial
12/12/2022HVAC-R and service water heating equipmentSHAHIN BADALYenergy_progress
12/12/2022HVAC-R and service water heating system controlsSHAHIN BADALYenergy_progress
07/09/2021Maintenance informationSHAHIN BADALYenergy_progress
07/09/2021HVAC-R and service water piping design and insulationSHAHIN BADALYenergy_progress
07/09/2021Fire-Resistant Penetrations and JointsSHAHIN BADALYspecial
07/09/2021HVAC-R and service water heating equipmentSHAHIN BADALYenergy_progress
Latest 25 of 26.
▾Documents — 72 on file (BIS + DOB NOW)
▸Plans & Drawings6
▸DOB NOWPlans/Sketch6
08/25/2026X00504910-P1Request digital key ↗
08/25/2026X00504910-I1Request digital key ↗
08/25/2026X00504911-I1Request digital key ↗
Showing 3 of 6 on file for this type
▸Applications & Permits9
▸BISPLAN / WORK APPROVAL APPLICATION5
02/16/2023220727943Open ↗
02/13/2023220727943Open ↗
06/07/2021220727943Open ↗
Showing 3 of 5 on file for this type
▸BISWORK PERMIT APPLICATION4
11/29/2022220727943Open ↗
10/25/2021220727943Open ↗
01/14/2021220727943Open ↗
Showing 3 of 4 on file for this type
▸Seals & Professional Certifications35
▸DOB NOWProgress Inspector Seal & Signature20
09/02/2026X00504910-I1Open ↗
09/02/2026X00504910-I1Open ↗
09/02/2026X00504910-I1Open ↗
Showing 3 of 20 on file for this type
▸DOB NOWDPL-1: Design Professional Seal & Signature6
08/25/2026X00504910-I1Open ↗
08/25/2026X00504910-P1Open ↗
08/25/2026X00504911-P1Open ↗
Showing 3 of 6 on file for this type
▸DOB NOWSpecial Inspector Seal & Signature6
09/02/2026X00504910-I1Open ↗
09/02/2026X00504910-I1Open ↗
08/25/2026X00504910-P1Open ↗
Showing 3 of 6 on file for this type
▸BISPROFESSIONAL CERTIFICATION STATEMENT1
03/05/2020220727943Open ↗
▸BISPROFESSIONAL CERTIFIED CHECKLIST1
03/05/2020220727943Open ↗
▸BISTECHNICAL REPORT: RESPONSIBILITY/CERTIFICATION1
03/05/2020220727943Open ↗
▸Environmental & Asbestos7
▸DOB NOWDEP ACP-5: Asbestos Assessment Report6
08/25/2026X00504910-P1Open ↗
08/25/2026X00504910-I1Open ↗
08/25/2026X00504911-P3Open ↗
Showing 3 of 6 on file for this type
▸BISASBESTOS: CERTIFICATION (DEP ACP5)1
03/05/2020220727943Open ↗
▸Energy Compliance4
▸DOB NOWEN2: As Built Energy Analysis.2
08/13/2026X00504910-I1Open ↗
08/13/2026X00504911-I1Open ↗
▸BISAS-BUILT ENERGY ANALYSIS (EN2)1
02/21/2023220727943Open ↗
▸BISTECHNICAL REPORT: ENERGY CODE PROGRESS INSPS1
03/05/2020220727943Open ↗
▸Approvals, Objections & Sign-offs2
▸BISCERTIFICATE OF OCCUPANCY/LOC: REQUEST1
02/22/2023220727943Open ↗
▸BISSUPERSEDING LETTER1
11/29/2022220727943Open ↗
▸Cost, Insurance & Ownership2
▸BISCOST AFFIDAVIT1
03/05/2020220727943Open ↗
▸BISCOST AFFIDAVIT (FINAL): PW31
02/21/2023220727943Open ↗
▸Filing & Intake Forms6
▸BISADDITIONAL INFORMATION5
02/16/2023220727943Open ↗
02/13/2023220727943Open ↗
11/29/2022220727943Open ↗
Showing 3 of 5 on file for this type
▸BISEFILING COVER SHEET1
03/05/2020220727943Open ↗
▸Other Documents1
▸BISCONSTRUCTION - SUPPORTING DOCUMENTATION1
11/29/2022220727943Open ↗