← Back
Three families
UNDERHILL AVENUE
BRONX · BIN 2130709
💬 Discuss this project
2023Year Built
3Stories
C0Building Class
R5Zoning
2,829 sfGross Floor Area
3Units
0 Open ViolationsFDNY Report ↗
Three families · Owner of record: 450 SOUNDVIEW AVE LLC · 2,586 sf lot · 1.09 FAR built · Flood zone X
Locations of Work
ArchitectureStructuralMechanicalPlumbingFire ProtectionGeneral
Floor 81p · 1 filing · 17 docs
Floor 7
Floor 6
Floor 5
Floor 4
Floor 337p · 2 filings · 20 docs
Floor 237p · 2 filings · 20 docs
Floor 138p · 2 filings · 20 docs
Cellar37p · 2 filings · 20 docs
▾Owner History (Filing Record)
Companies and organizations named on filings. Individual owners are not shown.
OwnerFilingsMost Recent
JAK REALTY5004/09/2026
450 SOUNDVIEW AVE LLC103/22/2026
▾Sales History (ACRIS)
DatePriceUnitSeller → Buyer$/sf
10/23/2025$1.1M—— → —$395/sf building
03/09/2021$400K—HISPANIC TRANSIT SOCIETY, INC. → Private party— not available
▾Design Consultants (Architect / Engineer of Record)
FirmFilingsMost Recent
BADALY ARCHITECTS1210/30/2024
BADALY ENGINEERING PLLC112/07/2022
▾Filing Representatives (Expediters)
RepresentativeFilingsMost Recent
KC EXPEDITING INC103/21/2026
▾Contractors (License-Anchored)
FirmTradeRolesMost Recent
ZEFI & CO. LLCGeneral Contractor1104/09/2026
LLOYD G DRUMMOND PLBG&GENFire Protection207/08/2026
DOUG'S PLBG & HTG SERV COFire Protection107/08/2026
DOUG'S PLBG & HTG SERV COPlumbing107/08/2026
LLOYD G DRUMMOND PLBG&GENPlumbing107/08/2026
▾Special Inspection Agencies
AgencyLicense #FilingsMost Recent
BADALY ARCHITECT PLLC7137910/30/2024
Building Lifecycle
All (95)Filed (13)Permit Issued (14)Signed Off (4)Inspection (10)Objection (24)Special Inspection (30)
07/28/2025
Signed off — New Building
CC APPLICATION FILED IN CONJUNCTION WITH NB # X00670922-I1 AND BPP# 240357190
X00670922-S3
06/18/2025
Inspection — Pass-Final Curb Cut Non-Directive 14
Pass
View inspection ↗
06/12/2025
Signed off — New Building
CC APPLICATION FILED IN CONJUNCTION WITH NB # X00670922-I1 AND BPP# 240357190
X00670922-S1
06/02/2025
Permit issued — Curb Cut
X00670922-S3-CC
04/22/2025
Signed off — Alteration
Provide new fire sprinkler system and plumbing system in conjunction with NB application #X00670922
X00767845-I1
04/11/2025
Inspection — Pass-Final CND-Occupancy Inspection
Pass
View inspection ↗
03/11/2025
Inspection — Pass-Final CND-Occupancy Inspection
Pass
View inspection ↗
03/10/2025
Signed off — New Building
CC APPLICATION FILED IN CONJUNCTION WITH NB # X00670922-I1 AND BPP# 240357190
X00670922-S2
12/05/2024
Permit issued — Foundation
X00670922-I1-MS
12/04/2024
Inspection — Certified Sprinkler-SP-Fixtures-Finish
Certified
View inspection ↗
12/02/2024
Inspection — Certified Sprinkler-SP-Piping Dry/Wet-Hydrostatic Test
Certified
View inspection ↗
11/27/2024
Inspection — Certified Sprinkler-SP-Piping Dry/Wet-Hydrostatic Test
Certified
View inspection ↗
11/15/2024
Permit issued — Sprinklers
X00767845-I1-EW-SP
11/14/2024
Permit issued — Sprinklers
X00767845-I1-PL
11/14/2024
Special inspection requirement — Interior lighting power
MOHAMMAD BADALY
11/14/2024
Special inspection requirement — Fenestration areas
MOHAMMAD BADALY
11/14/2024
Special inspection requirement — Electric vehicle service equipment requirements
MOHAMMAD BADALY
11/14/2024
Special inspection requirement — Insulation placement and R values
MOHAMMAD BADALY
11/14/2024
Special inspection requirement — HVAC-R and service water heating system controls
MOHAMMAD BADALY
11/14/2024
Special inspection requirement — Heating Systems
MOHAMMAD BADALY
11/14/2024
Special inspection requirement — Mechanical Systems
MOHAMMAD BADALY
11/14/2024
Special inspection requirement — Concrete - Cast-In-Place
MOHAMMAD BADALY
11/14/2024
Special inspection requirement — Wood – Prefabricated I-Joists
MOHAMMAD BADALY
11/14/2024
Special inspection requirement — Excavations - Sheeting, Shoring, and Bracing
MOHAMMAD BADALY
11/14/2024
Special inspection requirement — Fire-Resistant Penetrations and Joints
MOHAMMAD BADALY
11/14/2024
Special inspection requirement — Chimneys and vents
MOHAMMAD BADALY
11/14/2024
Special inspection requirement — Masonry
MOHAMMAD BADALY
11/14/2024
Special inspection requirement — Structural Cold-Formed Steel
MOHAMMAD BADALY
11/14/2024
Special inspection requirement — Subgrade Inspections
MOHAMMAD BADALY
11/14/2024
Special inspection requirement — Wood – Seismic Resistance
MOHAMMAD BADALY
11/14/2024
Special inspection requirement — Fire-Resistance Rated Construction
MOHAMMAD BADALY
11/14/2024
Special inspection requirement — Structural Wood Frame
MOHAMMAD BADALY
11/14/2024
Special inspection requirement — Energy Code Compliance Inspections
MOHAMMAD BADALY
11/14/2024
Special inspection requirement — Final
MOHAMMAD BADALY
11/14/2024
Special inspection requirement — Footing and Foundation
MOHAMMAD BADALY
11/14/2024
Special inspection requirement — Air barrier — testing
MOHAMMAD BADALY
11/14/2024
Special inspection requirement — HVAC-R and service water piping design and insulation
MOHAMMAD BADALY
11/14/2024
Special inspection requirement — Permanent certificate
MOHAMMAD BADALY
11/14/2024
Special inspection requirement — Fenestration and door U-factor and product ratings
MOHAMMAD BADALY
11/14/2024
Special inspection requirement — Air barrier - visual inspection
MOHAMMAD BADALY
11/14/2024
Special inspection requirement — Maintenance information
MOHAMMAD BADALY
11/14/2024
Special inspection requirement — Metering
MOHAMMAD BADALY
11/14/2024
Special inspection requirement — Ventilation and air distribution system
MOHAMMAD BADALY
11/14/2024
Special inspection requirement — HVAC-R and service water heating equipment
MOHAMMAD BADALY
11/07/2024
Objection resolved — Addressed
11/06/2024
Inspection — Pass-Final CND-Occupancy Inspection
Pass
View inspection ↗
11/04/2024
Objection raised — Other
10/30/2024
Filed — New Building
CC APPLICATION FILED IN CONJUNCTION WITH NB # X00670922-I1 AND BPP# 240357190
X00670922-P5
08/08/2024
Permit issued — Structural
X00670922-I1-GC-CX
07/02/2024
Permit issued — Plumbing
X00767845-I1-EW-SP
02/02/2024
Objection resolved — Addressed
01/25/2024
Permit issued — Construction Fence
X00670922-S1-FN
12/29/2023
Filed — New Building
CC APPLICATION FILED IN CONJUNCTION WITH NB # X00670922-I1 AND BPP# 240357190
X00670922-P4
12/29/2023
Objection raised — Other
12/13/2023
Filed — New Building
CC APPLICATION FILED IN CONJUNCTION WITH NB # X00670922-I1 AND BPP# 240357190
X00670922-S3
12/05/2023
Filed — Alteration
Provide new fire sprinkler system and plumbing system in conjunction with NB application #X00670922
X00767845-P3
10/13/2023
Permit issued — Support of Excavation
X00670922-S2-SE
09/28/2023
Filed — Alteration
Provide new fire sprinkler system and plumbing system in conjunction with NB application #X00670922
X00767845-P2
09/12/2023
Inspection — Pass-Final PL - Up to 3 Requested Floors
Pass
View inspection ↗
08/25/2023
Permit issued — Mechanical Systems
X00670922-I1-GC-CX
Latest 60 of 95 events.
Permit / Filing Register
SourceWork TypeStatusApplicantIssued
DOB NOWCurb CutSigned-offZEFI & CO. LLC06/02/2025
DOB NOWFoundationSigned-offZEFI & CO. LLC12/05/2024
DOB NOWSprinklersSigned-offDOUG'S PLBG & HTG SERV CO11/15/2024
DOB NOWSprinklersSigned-offDOUG'S PLBG & HTG SERV CO11/14/2024
DOB NOWStructuralPermit IssuedZEFI & CO. LLC08/08/2024
DOB NOWPlumbingSigned-offLLOYD G. DRUMMOND07/02/2024
DOB NOWConstruction FenceSigned-offZEFI & CO. LLC01/25/2024
DOB NOWSupport of ExcavationSigned-offZEFI & CO. LLC10/13/2023
DOB NOWMechanical SystemsPermit IssuedZEFI & CO. LLC08/25/2023
DOB NOWMechanical SystemsPermit IssuedZEFI & CO. LLC05/26/2023
DOB NOWSprinklersSigned-offLLOYD G. DRUMMOND02/22/2023
DOB NOWPlumbingSigned-offLLOYD G DRUMMOND PLBG&GEN02/22/2023
DOB NOWConstruction FenceSigned-offZEFI & CO. LLC02/01/2023
DOB NOWFoundationSigned-offZEFI & CO. LLC01/27/2023
1 project · most recent 10/30/2024
Air Conditioning Systems Heating Systems Ventilation Systems
FiledStatusContractorScopeMake / Model / Capacity
10/30/2024Signed-offZEFI & CO. LLCAir Conditioning Systems, Heating Systems, Ventilation Systems
Cooling
Islandaire EX series 42 9,300 BTU · Ptac ×27
EZ series 42 12,000 BTU · Ptac ×9
Friedrich WHT12A33A 12,000 BTU · Ptac ×12
Heating
Islandaire EZ series 42 12,300 BTU · Ptac ×36
Friedrich WHT12A33A 12,300 BTU · Ptac ×12
Navien NCB-240 120,000 BTU · Boiler ×3
Ventilation
Broan 696N, RL6230WH 100 CFM ×3
1 project · most recent 03/27/2025
General Wiring
FiledStatusContractorScope
03/27/2025CompleteJ&H ELECTRICAL CONT INCGeneral Wiring
1 project · most recent 10/30/2024
Masonry Wood
FiledStatusContractorScope
10/30/2024Signed-offZEFI & CO. LLCMasonry, Wood
1 project · most recent 10/30/2024
Fence
FiledStatusContractorScope
10/30/2024Signed-offZEFI & CO. LLCFence
▾Field Inspections (DOB CAP) — 10
DateTypeResultReport
06/18/2025Pass-Final Curb Cut Non-Directive 14PassView ↗
04/11/2025Pass-Final CND-Occupancy InspectionPassView ↗
03/11/2025Pass-Final CND-Occupancy InspectionPassView ↗
12/04/2024Certified Sprinkler-SP-Fixtures-FinishCertifiedView ↗
12/02/2024Certified Sprinkler-SP-Piping Dry/Wet-Hydrostatic TestCertifiedView ↗
11/27/2024Certified Sprinkler-SP-Piping Dry/Wet-Hydrostatic TestCertifiedView ↗
11/06/2024Pass-Final CND-Occupancy InspectionPassView ↗
09/12/2023Pass-Final PL - Up to 3 Requested FloorsPassView ↗
03/30/2023Certified Storm Drainage-ST-Piping-UndergroundCertifiedView ↗
03/30/2023Certified Water and Sanitary-WS-Sanitary Piping-UndergroundCertifiedView ↗
▾Special Inspection Requirements (DOB NOW) — 150
DateRequirementInspectorRole
11/14/2024Insulation placement and R valuesMOHAMMAD BADALYenergy_progress
11/14/2024Interior lighting powerMOHAMMAD BADALYenergy_progress
11/14/2024HVAC-R and service water heating system controlsMOHAMMAD BADALYenergy_progress
11/14/2024Fenestration areasMOHAMMAD BADALYenergy_progress
11/14/2024HVAC-R and service water heating equipmentMOHAMMAD BADALYenergy_progress
11/14/2024Fenestration air leakageMOHAMMAD BADALYenergy_progress
11/14/2024Heating SystemsMOHAMMAD BADALYspecial
11/14/2024Mechanical SystemsMOHAMMAD BADALYspecial
11/14/2024Concrete - Cast-In-PlaceMOHAMMAD BADALYspecial
11/14/2024Wood – Prefabricated I-JoistsMOHAMMAD BADALYspecial
11/14/2024Excavations - Sheeting, Shoring, and BracingMOHAMMAD BADALYspecial
11/14/2024Fire-Resistant Penetrations and JointsMOHAMMAD BADALYspecial
11/14/2024Chimneys and ventsMOHAMMAD BADALYspecial
11/14/2024MasonryMOHAMMAD BADALYspecial
11/14/2024Structural Cold-Formed SteelMOHAMMAD BADALYspecial
11/14/2024Subgrade InspectionsMOHAMMAD BADALYspecial
11/14/2024Wood – Seismic ResistanceMOHAMMAD BADALYspecial
11/14/2024Fire-Resistance Rated ConstructionMOHAMMAD BADALYprogress
11/14/2024Structural Wood FrameMOHAMMAD BADALYprogress
11/14/2024Energy Code Compliance InspectionsMOHAMMAD BADALYprogress
11/14/2024FinalMOHAMMAD BADALYprogress
11/14/2024Footing and FoundationMOHAMMAD BADALYprogress
11/14/2024Air barrier — testing MOHAMMAD BADALYenergy_progress
11/14/2024HVAC-R and service water piping design and insulationMOHAMMAD BADALYenergy_progress
11/14/2024Permanent certificateMOHAMMAD BADALYenergy_progress
Latest 25 of 150.
▾Documents — 116 on file (BIS + DOB NOW)
▸Plans & Drawings13
▸DOB NOWPlans/Sketch13
08/24/2026X00767845-P3Request digital key ↗
08/24/2026X00767845-P2Request digital key ↗
08/24/2026X00767845-P1Request digital key ↗
Showing 3 of 13 on file for this type
▸Applications & Permits2
▸BISPLAN / WORK APPROVAL APPLICATION1
11/02/2023240357190Open ↗
▸BISBPP-5 - Authorization to the Department of Transportation1
03/27/2024240357190Open ↗
▸Zoning, Tax Lot & Property Records11
▸DOB NOWZoning Exhibit form (1-5)5
08/23/2026X00670922-P1Open ↗
08/15/2026X00670922-P4Open ↗
08/15/2026X00670922-P2Open ↗
Showing 3 of 5 on file for this type
▸DOB NOWZD1: DOB Zoning Diagram5
08/23/2026X00670922-P1Open ↗
08/15/2026X00670922-P4Open ↗
08/15/2026X00670922-P2Open ↗
Showing 3 of 5 on file for this type
▸DOB NOWHouse Number Verification: TOPO Stamp1
08/13/2026X00670922-I1Open ↗
▸Seals & Professional Certifications45
▸DOB NOWProgress Inspector Seal & Signature16
09/23/2026X00767845-P3Open ↗
09/02/2026X00670922-P4Open ↗
09/02/2026X00670922-P4Open ↗
Showing 3 of 16 on file for this type
▸DOB NOWSpecial Inspector Seal & Signature14
09/23/2026X00767845-P3Open ↗
09/02/2026X00670922-P4Open ↗
09/02/2026X00670922-P4Open ↗
Showing 3 of 14 on file for this type
▸DOB NOWDPL-1: Design Professional Seal & Signature13
08/24/2026X00767845-P3Open ↗
08/24/2026X00767845-P2Open ↗
08/24/2026X00767845-P1Open ↗
Showing 3 of 13 on file for this type
▸BISTECHNICAL REPORT STATEMENT OF RESPONSIBILITY1
11/02/2023240357190Open ↗
▸BISAPPLICANT OWNER SIGNATURE1
11/02/2023240357190Open ↗
▸Trade Schedules & Equipment5
▸DOB NOWDEP: Sewer Certification (Sanitary/Storm)5
08/23/2026X00670922-P1Open ↗
08/15/2026X00670922-P4Open ↗
08/15/2026X00670922-P2Open ↗
Showing 3 of 5 on file for this type
▸Safety & Tenant Protection11
▸DOB NOWStreet Tree Checklist5
08/23/2026X00670922-P1Open ↗
08/15/2026X00670922-P4Open ↗
08/15/2026X00670922-P2Open ↗
Showing 3 of 5 on file for this type
▸BISSTREET TREES: RECEIPT OF STREET TREES SITE PLAN1
03/27/2024240357190Open ↗
▸BISBPP: STREET TREES SITE PLAN1
03/27/2024240357190Open ↗
▸BISSTREET TREE CHECKLIST1
03/27/2024240357190Open ↗
▸DOB NOWStreet Tree Sign Off1
08/13/2026X00670922-I1Open ↗
▸DOB NOWParks Department Acknowledgment Letter for Street Trees Plan1
08/13/2026X00670922-I1Open ↗
▸DOB NOWStreet Trees Site Plan1
08/13/2026X00670922-I1Open ↗
▸Energy Compliance2
▸DOB NOWEN2: As Built Energy Analysis2
08/13/2026X00670922-I1Open ↗
08/13/2026X00767845-I1Open ↗
▸Filing & Intake Forms2
▸BISEFILING JOB APPLICATION COVER SHEET1
11/02/2023240357190Open ↗
▸BISADDITIONAL INFORMATION1
03/27/2024240357190Open ↗
▸Other Documents25
▸BISBPP - SUPPORTING DOCUMENTATION7
06/03/2024240357190Open ↗
06/03/2024240357190Open ↗
03/27/2024240357190Open ↗
Showing 3 of 7 on file for this type
▸DOB NOWProperty Ownership Certification5
08/23/2026X00670922-P1Open ↗
08/15/2026X00670922-P4Open ↗
08/15/2026X00670922-P2Open ↗
Showing 3 of 5 on file for this type
▸DOB NOWLocal Law 92/94 of 2019 Sustainable Roof Zone5
08/23/2026X00670922-P1Open ↗
08/15/2026X00670922-P4Open ↗
08/15/2026X00670922-P2Open ↗
Showing 3 of 5 on file for this type
▸DOB NOWSite Survey: Initial5
08/23/2026X00670922-P1Open ↗
08/15/2026X00670922-P4Open ↗
08/15/2026X00670922-P2Open ↗
Showing 3 of 5 on file for this type
▸DOB NOWProject Specific General Liability (PGL1)1
08/13/2026X00670922-I1Open ↗
▸DOB NOWFinal Survey1
08/13/2026X00670922-I1Open ↗
▸DOB NOWAdjoining Owners Notification1
08/13/2026X00670922-S2Open ↗