← Back
Two family brick
464 JEFFERSON AVENUE
BROOKLYN · Bedford-Stuyvesant (East) · BIN 3052515
💬 Discuss this project
1899Year Built
3Stories
B1Building Class
R6BZoning
3,000 sfGross Floor Area
2Units
Rent Stabilized0 Open ViolationsFDNY Report ↗
Two family brick · 1,667 sf lot · 1.8 FAR built · Flood zone X
Locations of Work
ArchitectureStructuralPlumbingGeneral
Floor 18p · 2 filings · 20 docs
▾Sales History (ACRIS)
DatePriceUnitSeller → Buyer$/sf
06/27/2017$1.7M—Private party → Private party$567/sf building
▾Design Consultants (Architect / Engineer of Record)
FirmFilingsMost Recent
VICTOR CASTILLO ARCHITECT PC504/25/2023
▾Filing Representatives (Expediters)
RepresentativeFilingsMost Recent
KX CONSULTING1003/21/2026
▾Contractors (License-Anchored)
FirmTradeRolesMost Recent
CORINTO CONSTRUCTION CORPGeneral Contractor407/08/2026
BROOKYLN SOLARWORKS, LLCElectrical103/22/2026
SCARPONI&SON PLBG&HTG CORPlumbing107/08/2026
▾Special Inspection Agencies
AgencyLicense #FilingsMost Recent
AR ARCHITECT P.C.1171504/25/2023
NORMAN C. LOK818203/28/2023
Building Lifecycle
All (50)Filed (5)Permit Issued (3)Signed Off (2)Violation (5)Inspection (3)Objection (2)Special Inspection (30)
08/25/2023
Signed off — Alteration
MINOR INTERIOR RENOVATION ON EXISTING 1ST FL OF AN EXISTING 2 FAMILY HOUSE. WORK INCLUDE REMODELLING THE KITCHEN, INSTALATION OF A NEW (2)PIECES BATHROOM AND REDESIGN EXISTING REAR WINDOW AND DOOR. ALL AS PER PLANS. NO CHANGE IN USE,EGRESS OR OCCUPANCY.
B00793532-I1
08/25/2023
Signed off — Alteration
Replace and install new plumbing fixtures as per plans submitted herewith.
B00746398-I1
08/10/2023
Inspection — Certified Water and Sanitary-WS-Fixtures-Finish
Certified
View inspection ↗
08/04/2023
Inspection — Pass-Final PL - Up to 3 Requested Floors
Pass
View inspection ↗
05/05/2023
Inspection — Certified Water and Sanitary-WS-Sanitary Piping-Roughing
Certified
View inspection ↗
04/26/2023
Special inspection requirement — Fire-Resistant Penetrations and Joints
ANGEL ROJAS
04/26/2023
Special inspection requirement — Energy Code Compliance Inspections
ANGEL ROJAS
04/26/2023
Special inspection requirement — HVAC-R and service water piping design and insulation
ANGEL ROJAS
04/25/2023
Filed — Alteration
Replace and install new plumbing fixtures as per plans submitted herewith.
B00746398-P2
04/07/2023
Special inspection requirement — Energy Code Compliance Inspections
ANGEL ROJAS
04/07/2023
Special inspection requirement — Final
ANGEL ROJAS
04/07/2023
Special inspection requirement — Lighting in dwelling units
ANGEL ROJAS
04/07/2023
Special inspection requirement — Air barrier - visual inspection
ANGEL ROJAS
04/07/2023
Special inspection requirement — Fenestration and door U-factor and product ratings
ANGEL ROJAS
04/07/2023
Special inspection requirement — Insulation placement and R values
ANGEL ROJAS
04/07/2023
Special inspection requirement — Fenestration air leakage
ANGEL ROJAS
04/07/2023
Special inspection requirement — Structural Steel - Details
NORMAN LOK
04/07/2023
Special inspection requirement — Construction Operations Influencing Adjacent Structures
ANGEL ROJAS
04/07/2023
Special inspection requirement — Fire-Resistant Penetrations and Joints
ANGEL ROJAS
04/07/2023
Special inspection requirement — Structural Stability – Alterations of existing buildings
ANGEL ROJAS
04/07/2023
Special inspection requirement — Structural Steel - Welding
NORMAN LOK
04/07/2023
Special inspection requirement — Fire-Resistance Rated Construction
ANGEL ROJAS
04/03/2023
Objection resolved — Addressed
03/29/2023
Objection raised — Admin
03/28/2023
Filed — Alteration
MINOR INTERIOR RENOVATION ON EXISTING 1ST FL OF AN EXISTING 2 FAMILY HOUSE. WORK INCLUDE REMODELLING THE KITCHEN, INSTALATION OF A NEW (2)PIECES BATHROOM AND REDESIGN EXISTING REAR WINDOW AND DOOR. ALL AS PER PLANS. NO CHANGE IN USE,EGRESS OR OCCUPANCY.
B00793532-P1
03/28/2023
Filed — Alteration
Replace and install new plumbing fixtures as per plans submitted herewith.
B00746398-P1
03/27/2023
Special inspection requirement — Structural Steel - Details
NORMAN LOK
03/27/2023
Special inspection requirement — Construction Operations Influencing Adjacent Structures
ANGEL ROJAS
03/27/2023
Special inspection requirement — Fire-Resistant Penetrations and Joints
ANGEL ROJAS
03/27/2023
Special inspection requirement — Structural Stability – Alterations of existing buildings
ANGEL ROJAS
03/27/2023
Special inspection requirement — Structural Steel - Welding
NORMAN LOK
03/27/2023
Special inspection requirement — Energy Code Compliance Inspections
ANGEL ROJAS
03/27/2023
Special inspection requirement — Final
ANGEL ROJAS
03/27/2023
Special inspection requirement — Fire-Resistance Rated Construction
ANGEL ROJAS
03/27/2023
Special inspection requirement — Air barrier - visual inspection
ANGEL ROJAS
03/27/2023
Special inspection requirement — Fenestration air leakage
ANGEL ROJAS
03/27/2023
Special inspection requirement — Fenestration and door U-factor and product ratings
ANGEL ROJAS
03/27/2023
Special inspection requirement — Lighting in dwelling units
ANGEL ROJAS
03/27/2023
Special inspection requirement — Insulation placement and R values
ANGEL ROJAS
03/07/2023
Special inspection requirement — Fire-Resistant Penetrations and Joints
ANGEL ROJAS
02/28/2023
Permit issued — Plumbing
B00746398-I1-PL
01/31/2023
Permit issued — General Construction
B00793532-I1-GC-CX
01/19/2023
Permit issued — Structural
B00793532-I1-GC-CX
11/29/2022
Filed — Alteration
Replace and install new plumbing fixtures as per plans submitted herewith.
B00746398-I1
11/21/2022
Filed — Alteration
MINOR INTERIOR RENOVATION ON EXISTING 1ST FL OF AN EXISTING 2 FAMILY HOUSE. WORK INCLUDE REMODELLING THE KITCHEN, INSTALATION OF A NEW (2)PIECES BATHROOM AND REDESIGN EXISTING REAR WINDOW AND DOOR. ALL AS PER PLANS. NO CHANGE IN USE,EGRESS OR OCCUPANCY.
B00793532-I1
10/09/2015
Violation issued (HPD, closed)
I
02/23/2015
Violation issued (HPD, closed)
I
09/11/1991
Violation issued (HPD, closed)
A
05/07/1982
Violation issued (HPD, closed)
A
08/13/1980
Violation issued (HPD, closed)
I
Permit / Filing Register
SourceWork TypeStatusApplicantIssued
DOB NOWPlumbingSigned-offSCARPONI&SON PLBG&HTG COR02/28/2023
DOB NOWGeneral ConstructionSigned-offCORINTO CONSTRUCTION CORP01/31/2023
DOB NOWStructuralSigned-offCORINTO CONSTRUCTION CORP01/19/2023
BISOTISSUEDBROOKLYN SOLARWORKS LLC02/02/2023
BISPLISSUEDJOHNNY'S P&H CONTRAC INC09/28/2017
BISPLISSUEDM & J PLBG & MECHANICAL CORP07/12/2000
BIS—ISSUEDSTRTTEGIC CONSTRUCTION CORP11/18/1999
BISEQISSUEDSTRTTEGIC CONSTRUCTION CORP11/18/1999
BISPLISSUEDM BURTON P & H CORP09/29/1999
BISEQISSUEDSTRTTEGIC CONSTRUCTION CORP05/06/1999
BIS—ISSUEDSTRTTEGIC CONSTRUCTION CORP05/06/1999
BISEQISSUEDSEAMAN M. CONSTRUCTION CORP11/25/1998
1 project · most recent 03/03/2023
FiledStatusContractorScope
03/03/2023CompleteBROOKYLN SOLARWORKS, LLC—
▾Field Inspections (DOB CAP) — 3
DateTypeResultReport
08/10/2023Certified Water and Sanitary-WS-Fixtures-FinishCertifiedView ↗
08/04/2023Pass-Final PL - Up to 3 Requested FloorsPassView ↗
05/05/2023Certified Water and Sanitary-WS-Sanitary Piping-RoughingCertifiedView ↗
▾Special Inspection Requirements (DOB NOW) — 32
DateRequirementInspectorRole
04/26/2023Fire-Resistant Penetrations and JointsANGEL ROJASspecial
04/26/2023Energy Code Compliance InspectionsANGEL ROJASprogress
04/26/2023HVAC-R and service water piping design and insulationANGEL ROJASenergy_progress
04/07/2023Energy Code Compliance InspectionsANGEL ROJASprogress
04/07/2023FinalANGEL ROJASprogress
04/07/2023Lighting in dwelling unitsANGEL ROJASenergy_progress
04/07/2023Air barrier - visual inspectionANGEL ROJASenergy_progress
04/07/2023Fenestration and door U-factor and product ratingsANGEL ROJASenergy_progress
04/07/2023Insulation placement and R valuesANGEL ROJASenergy_progress
04/07/2023Fenestration air leakageANGEL ROJASenergy_progress
04/07/2023Structural Steel - DetailsNORMAN LOKspecial
04/07/2023Construction Operations Influencing Adjacent StructuresANGEL ROJASspecial
04/07/2023Fire-Resistant Penetrations and JointsANGEL ROJASspecial
04/07/2023Structural Stability – Alterations of existing buildingsANGEL ROJASspecial
04/07/2023Structural Steel - WeldingNORMAN LOKspecial
04/07/2023Fire-Resistance Rated ConstructionANGEL ROJASprogress
03/27/2023Structural Steel - DetailsNORMAN LOKspecial
03/27/2023Construction Operations Influencing Adjacent StructuresANGEL ROJASspecial
03/27/2023Fire-Resistant Penetrations and JointsANGEL ROJASspecial
03/27/2023Structural Stability – Alterations of existing buildingsANGEL ROJASspecial
03/27/2023Structural Steel - WeldingNORMAN LOKspecial
03/27/2023Energy Code Compliance InspectionsANGEL ROJASprogress
03/27/2023FinalANGEL ROJASprogress
03/27/2023Fire-Resistance Rated ConstructionANGEL ROJASprogress
03/27/2023Air barrier - visual inspectionANGEL ROJASenergy_progress
Latest 25 of 32.
▾Documents — 80 on file (BIS + DOB NOW)
▸Plans & Drawings5
▸DOB NOWPlans/Sketch5
08/28/2026B00793532-I1Request digital key ↗
08/27/2026B00746398-I1Request digital key ↗
08/27/2026B00746398-P2Request digital key ↗
Showing 3 of 5 on file for this type
▸Applications & Permits5
▸BISPLAN / WORK APPROVAL APPLICATION2
02/01/2023340878125Open ↗
09/18/2017321652350Open ↗
▸BISWORK PERMIT APPLICATION2
02/02/2023340878125Open ↗
09/29/2017321652350Open ↗
▸BISPLAN - WORK & PERMITS - SUPPPORTING DOCUMENTATION1
11/09/2017321652350Open ↗
▸Seals & Professional Certifications41
▸DOB NOWProgress Inspector Seal & Signature20
09/01/2026B00746398-I1Open ↗
09/01/2026B00746398-I1Open ↗
08/28/2026B00746398-P1Open ↗
Showing 3 of 20 on file for this type
▸DOB NOWSpecial Inspector Seal & Signature12
09/01/2026B00746398-I1Open ↗
08/28/2026B00746398-P1Open ↗
08/26/2026B00793532-I1Open ↗
Showing 3 of 12 on file for this type
▸DOB NOWDPL-1: Design Professional Seal & Signature5
08/28/2026B00793532-I1Open ↗
08/28/2026B00793532-P1Open ↗
08/27/2026B00746398-P1Open ↗
Showing 3 of 5 on file for this type
▸BISPROFESSIONAL CERTIFICATION STATEMENT1
09/18/2017321652350Open ↗
▸BISAPPLICANT OWNER SIGNATURE1
02/01/2023340878125Open ↗
▸BISPROFESSIONAL CERTIFIED CHECKLIST1
09/18/2017321652350Open ↗
▸BISTECHNICAL REPORT: RESPONSIBILITY/CERTIFICATION1
09/18/2017321652350Open ↗
▸Trade Schedules & Equipment1
▸BISSCHEDULE B - PLUMBING/SPRINKLER/STANDPIPE1
09/18/2017321652350Open ↗
▸Safety & Tenant Protection2
▸BISTPP1: TENANT PROTECTION PLAN1
02/02/2023340878125Open ↗
▸BISTenant Protection Plan and Notes1
09/18/2017321652350Open ↗
▸Environmental & Asbestos6
▸DOB NOWDEP ACP-5: Asbestos Assessment Report5
08/28/2026B00793532-I1Open ↗
08/27/2026B00746398-P1Open ↗
08/27/2026B00746398-I1Open ↗
Showing 3 of 5 on file for this type
▸BISASBESTOS: CERTIFICATION (DEP ACP5)1
02/01/2023340878125Open ↗
▸Energy Compliance8
▸BISTECHNICAL REPORT: ENERGY CODE - RESPONSIBILITY3
05/04/2023340878125Open ↗
05/04/2023340878125Open ↗
02/01/2023340878125Open ↗
▸BISAS-BUILT ENERGY ANALYSIS2
05/04/2023340878125Open ↗
05/04/2023340878125Open ↗
▸BISSOLAR TAX ABATEMENT APPLICATION1
05/05/2023340878125Open ↗
▸BISPTA4: SOLAR TAX ABATEMENT APPLICATION (PRELIMINARY)1
02/01/2023340878125Open ↗
▸BISTECHNICAL REPORT: ENERGY CODE PROGRESS INSPS1
09/18/2017321652350Open ↗
▸Inspections & Test Reports4
▸BISTECHNICAL REPORT: RESPONSIBILITY4
05/04/2023340878125Open ↗
05/04/2023340878125Open ↗
05/04/2023340878125Open ↗
Showing 3 of 4 on file for this type
▸Approvals, Objections & Sign-offs2
▸BISLETTERS - SUPPORTING DOCUMENTATION1
05/05/2023340878125Open ↗
▸BISCERTIFICATE OF OCCUPANCY/LOC: REQUEST1
05/05/2023340878125Open ↗
▸Cost, Insurance & Ownership4
▸BISCOST AFFIDAVIT4
05/04/2023340878125Open ↗
05/04/2023340878125Open ↗
02/01/2023340878125Open ↗
Showing 3 of 4 on file for this type
▸Filing & Intake Forms2
▸BISEFILING COVER SHEET1
09/18/2017321652350Open ↗
▸BISEFILING JOB APPLICATION COVER SHEET1
02/01/2023340878125Open ↗