ECB08/25/2026FAILURE TO SUBMIT CERTIFICATE OF CORRECTION OF VIOLATION #35581614K ISSUED ON 05-16-2025 FOR WORK WITHOUT A PERMIT., COMPLY WITH COMMISSIONER'S ORDER$2K due
ECB08/25/2026AT TIME OF INSPECTION OBSERVED FACADE IN NEED OF REPAIR BETWEEN 2ND AND 3RD FLOOR BRICK ARE STARTING TO BULGE BROWNSTONE ALSO IN DISREPAIR VIOLATION #35581613Z ISSUED ON 05-16-2025 FOR FAILURE TO MAINTAIN BUILD$6K due
HPD07/26/2026§ 27-2005 ADM CODE REPAIR THE BROKEN OR DEFECTIVE PLASTERED SURFACES AND PAINT IN A UNIFORM COLOR AT CEILING IN THE 1st ROOM FROM EAST AT SOUTH LOCATED AT APT B, 1st STORY, 2nd APARTMENT FROM NORTH AT EAST
HPD07/26/2026§ 27-2005 ADM CODE & 309 M/D LAW ABATE THE NUISANCE CONSISTING OF TAPED LATCH ASSEMBLY AT VESTIBULE DOOR AT PUBLIC HALL, 1st STORY
HPD07/26/2026HMC ADM CODE: § 27-2017.4 ABATE THE INFESTATION CONSISTING OF ROACHES IN THE ENTIRE APARTMENT LOCATED AT APT B, 1st STORY
HPD07/26/2026§ 27-2026, 2027 HMC: PROPERLY REPAIR THE SOURCE AND ABATE THE EVIDENCE OF A WATER LEAK AT CEILING IN THE 1st ROOM FROM EAST AT SOUTH LOCATED AT APT B, 1st STORY, 2nd APARTMENT FROM NORTH AT EAST
HPD07/04/2026HMC ADM CODE: § 27-2017.4 ABATE THE INFESTATION CONSISTING OF ROACHES IN THE ENTIRE APARTMENT LOCATED AT APT B, 1st STORY, 1st APARTMENT FROM NORTH AT EAST
HPD07/04/2026HMC ADM CODE: § 27-2017.4 ABATE THE INFESTATION CONSISTING OF ROACHES IN THE ENTIRE APARTMENT LOCATED AT APT B, 1st STORY, 1st APARTMENT FROM NORTH AT EAST
HPD06/24/2026§ 27-2005, 27-2007, 27-2041.1 HMC, §238, § 309; § 107 (2) ( C) MDL AND 28 RCNY §25-171: REPLACE OR REPAIR THE SELF-CLOSING DOORS THAT IS MISSING OR DEFECTIVE HINGES IN THE ENTRANCE LOCATED AT APT 1D, 2nd STORY, 1st APARTMENT FROM SOUTH AT WEST
HPD06/24/2026§ 27-2033 ADM CODE PROVIDE READY ACCESS TO BUILDINGS HEATING SYSTEM DOOR LOCKED AT CELLER AT BOILER ROOM
HPD06/19/2026§ 27-2005 ADM CODE REPAIR THE BROKEN OR DEFECTIVE PLASTERED SURFACES AND PAINT IN A UNIFORM COLOR CEILING IN THE 2nd ROOM FROM NORTH LOCATED AT APT B, 1st STORY, 2nd APARTMENT FROM NORTH AT EAST
HPD06/17/2026§ 27-2033 ADM CODE PROVIDE READY ACCESS TO BUILDINGS HEATING SYSTEM DOOR LOCKED AT BASEMENT
HPD06/17/2026§ 27-2033 ADM CODE PROVIDE READY ACCESS TO BUILDINGS HEATING SYSTEM DOOR LOCKED AT BASEMENT AT BOILER ROOM
HPD06/16/2026§ 27-2033 ADM CODE PROVIDE READY ACCESS TO BUILDINGS HEATING SYSTEM DOOR LOCKED AT BASEMENT AT BOILER ROOM
HPD06/13/2026§ 27-2033 ADM CODE PROVIDE READY ACCESS TO BUILDINGS HEATING SYSTEM DOOR LOCKED AT CELLER AT BOILER ROOM
HPD05/14/2026§ 300 M/D LAW FILE PLANS AND APPLICATION AND LEGALIZE THE FOLLOWING ALTERATION OR RESTORE TO THE LEGAL CONDITION EXISTING PRIOR TO THE MAKING OF SAID ALTERATION ILLEGAL CONVERSION OF GAS RANGE STOVE TO ELECTRIC STOVE IN THE KITCHEN LOCATED AT APT A, 1st STORY, 1st APARTMENT FROM NORTH AT EAST
HPD04/11/2026§ 27-2005, 27-2007, 27-2041.1 HMC, §238, § 309; § 107 (2) ( C) MDL AND 28 RCNY §25-171: REPLACE OR REPAIR THE SELF-CLOSING DOORS THAT IS MISSING OR DEFECTIVE HINGES AT BUILDING ENTRANCE DOOR
DOB07/01/2025FAILURE TO MAINTAIN.@TIME OF INSPECTION,OBSRBD THE MASONRY STEPS@THE FRNT ENTRANCE TO BE IN A STATE OF DISREPAIR W/STEEL ANGLE LINTELS POTENTIAL FOR CLLPSE.EXP1 FACADE IS IN DISREPAIR W/LOOSE&SPLLD.COMPLY WITH COMMISSIONER'S ORDER:DOB VIOLATION #051925FEU11201AK (CONTROL #342035) IMMEDIATELY
HPD06/17/2025§ 27-2056.6 ADM CODE - CORRECT THE LEAD-BASED PAINT HAZARD - PRESUMED LEAD PAINT THAT IS PEELING OR ON A DETERIORATED SUBSURFACE USING WORK PRACTICES SET FORTH IN 28 RCNY §11-06(B)(2) 1st RADIATOR FROM NORTH AT EAST WALL IN THE 4th ROOM FROM EAST LOCATED AT APT 3A, 4th STORY, 1st APARTMENT FROM NORTH AT EAST
HPD06/11/2025567 (C) § 27-2017, 27-2017.1, 27-2017.4, 27-2017.5, 27-2017.8, 27-2019, 27-2021 HMC: ABATE THE NUISANCE CONSISTING OF EVIDENCE OF RATS AND ALL UNDERLYING CAUSES CREATING THE PEST INFESTATIONS, BY USING INTEGRATED PEST MANAGEMENT (IPM), ELIMINATE ALL BURROW ENTRY AND PASSAGEWAYS, PEST NESTS, HOLES, GAPS OR CRACKS IN WALLS, CEILINGS, FLOORS, FIXING LEAKS AND MANAGING GARBAGE IN PUBLIC AREAS. EVIDENCE FOUND AT ALL YARDS
DOB05/19/2025FAILURE TO MAINTAIN.@TIME OF INSPECTION,OBSRVD THE MASONRY STEPS@THE FRNT ENTRANCE TO BE IN A STATE OF DISREPAIR W/STEEL LINTELS.POTENTIAL FOR CLLPSE.EXP1 FACADE IS IN DISREPAIR W/LOOSE&SPALLD.COMPLY WITH COMMISSIONER'S ORDER:DOB VIOLATION #051925FEU11201AK(CONTROL #342035) IMMEDIATELY
ECB05/16/2025AT TIME OF INSPECTION WE WERE RESPONDING TO A INCIDENT BY NYPD AND OBSERVED FACADE IN NEED OF REPAIR BETWEEN 2ND AND 3RD FLOOR BRICK ARE STARTING TO BULGE FRPM FACADE/ 1ST LEVEL SPAULDING OF BROWNSTONE ABOVE TR$12K due
DOB05/16/2025AT TIME OF INSPECTION I OBERVED A STAIRS LEANING INTO THE MAIN ENTRANC E IN DISREAPAIR WITH PLYWOOD AND 2X4 SUPPORTING STRUCTURE FRON UNDERNE ATH *** OWNER TO HIRE NYSPE TO SUBMIT ENGINEER REPORT TO ERTINSPECTI ONS@BUILDINGS.NYC.GOV WITHIN 30 DAYS ADDRESSING ALL CONDITIONS W/PLANS PHOTOS, RECOMENDING TIME FRAME AND TIME TO BE COMPLETED
ECB02/22/2024FOUND HB SMITH 28X4 GAS FIRED BOILER NOT OPERABLE, EXPOSED WIRING, BOILER ROOM DOOR NOT SELF CLOSING, NO LIGHTS IN BOILER ROOM, DISCHARGE PIPE MISSING AT BACK FLOW PREVENTER,$3K due
HPD04/22/2022§ 27-2005 ADM CODE PROPERLY REPAIR WITH SIMILAR MATERIAL THE BROKEN OR DEFECTIVE WOOD FLOOR HOLES TRIP HAZARD IN THE KITCHEN LOCATED AT APT C, 1st STORY, 1st APARTMENT FROM SOUTH AT WEST
HPD10/09/2021§ 27-2070 ADM CODE PROVIDE AN ADEQUATE SUPPLY OF GAS TO THE FIXTURES AT RANGE IN THE KITCHEN LOCATED AT APT 4D, 4th STORY, 1st APARTMENT FROM SOUTH AT WEST
HPD08/04/2021§ 27-2070 ADM CODE PROVIDE AN ADEQUATE SUPPLY OF GAS TO THE FIXTURES AT RANGE IN THE KITCHEN LOCATED AT APT A, 1st STORY, 1st APARTMENT FROM NORTH AT EAST
HPD07/08/2021§ 27-2070 ADM CODE PROVIDE AN ADEQUATE SUPPLY OF GAS TO THE FIXTURES - AT RANGE IN THE KITCHEN LOCATED AT APT A, 1st STORY, 1st APARTMENT FROM NORTH AT EAST
DOB04/06/2018VIOLATION ISSUED FOR FAILURE TO FILE ANNUAL BOILER 2016 INSPECTION REPORT
DOB03/03/2015VIOLATION ISSUED FOR FAILURE TO FILE ANNUAL BOILER 2013 INSPECTION REPORT
DOB02/27/2001V-DOB VIOLATION - ACTIVE
ECB05/16/2025AT TIME OF INSPECTION I WAS RESPONDING TO A REQUEST FROM NYPD. I OBSERVED MAIN STAIRS FROM STREET LEVEL IN DISREPAIR WITH LANDINGS NOT SECURED, ABLE TO BE LIFTED UP. UNDERNEATH THE STAIR OBSERVED PLYWOOD AND 2XHearing held — result not yet published$2K proposed
ECB05/10/2021LWC NOT ELECT. WIRED-NO SPILL SWITCH ON BARO. DAMPER-STOP LEFT ON DAMPER-RETURN CORRO AT BLOW DOWN VALVE-BURNER CONTROL COVER OFF-DRIP NOT CONNECT TO BACKFLOW; CORRECT COND'TNS. SUBMIT CERT OF CORRECT'N.Nothing owed — awaiting certificate of correction