| Owner | Filings | Most Recent |
|---|---|---|
| Webster | 2 | 08/28/2026 |
| 4685 Manhattan College Parkway | 1 | 03/22/2026 |
| Mitchell Enterprises | 1 | 03/21/2026 |
| Firm | Filings | Most Recent |
|---|---|---|
| Chong | 2 | 08/21/2026 |
| Source | Work Type | Status | Applicant | Issued |
|---|---|---|---|---|
| BIS | FP | ISSUED | NY Fire | 03/19/2015 |
| BIS | — | ISSUED | Neptune Signs & Awnings | 12/26/2014 |
| BIS | OT | ISSUED | Super Power Construction | 10/23/2014 |
| BIS | PL | ISSUED | Tri State Plumbing & Heating | 10/21/2014 |
| BIS | MH | ISSUED | Super Power Construction | 10/21/2014 |
| BIS | MH | ISSUED | Integra Construction of | 09/04/2009 |
| BIS | PL | ISSUED | Integra Plumbing of N.Y | 09/04/2009 |
| BIS | EQ | ISSUED | Cru Mechanical & Heating | 01/29/2002 |
| BIS | OT | ISSUED | Cru Mechanical & Heating | 01/29/2002 |
| BIS | PL | ISSUED | C.R.U. Mechan & Heating | 01/29/2002 |
| BIS | PL | ISSUED | Signore & Sons Plumbing | 03/14/1995 |
| BIS | — | ISSUED | Master Fire Prevention System | 03/14/1995 |
| BIS | PL | ISSUED | Martin J. Lara Plumbing | 04/23/1991 |
| BIS | OT | ISSUED | D. J. N. Construction | 04/15/1991 |
| Filed | Status | Contractor | Scope | Make / Model / Capacity |
|---|---|---|---|---|
| 08/21/2026 | — | — | Heating and Air Conditioning Systems | Heat / Cool Daikin FXFA18AAVJU 18,000 BTU · Vrf Indoor ×2 CTXV07AVJU9 7,000 BTU · Fan Coil Indoor ×1 FXAA12AAVJU 12,000 BTU · Vrf Indoor ×1 RXTA60AAVJU 60,000 BTU · Vrf Outdoor ×1 |
| Filed | Status | Contractor | Scope |
|---|---|---|---|
| 08/21/2026 | — | — | Gas, Water/Sanitary |
| Filed | Status | Contractor | Scope |
|---|---|---|---|
| 10/12/2026 | Permit Issued | Delta Power Electrical | General Wiring |
| 08/14/2020 | Permit Issued | Joseph Weinstein Electric | General Wiring |
| Filed | Status | Contractor | Scope |
|---|---|---|---|
| 08/21/2026 | — | — | 1 scope_items |
| Date | Requirement | Inspector | Role |
|---|---|---|---|
| 08/17/2026 | Energy Code Compliance Inspections | — | progress |
| 08/17/2026 | Fire-Resistant Penetrations and Joints | — | special |
| 08/17/2026 | HVAC-R and service water heating equipment | — | energy_progress |
| 08/17/2026 | Fire-Resistant Penetrations and Joints | — | special |
| 08/17/2026 | Energy Code Compliance Inspections | — | progress |
| 08/17/2026 | HVAC-R and service water piping design and insulation | — | energy_progress |
| 08/17/2026 | HVAC-R and service water heating system controls | — | energy_progress |
| 08/17/2026 | Interior lighting power | — | energy_progress |
| 08/17/2026 | Lighting controls | — | energy_progress |
| 08/07/2026 | Final | — | progress |
| 08/07/2026 | Mechanical Systems | — | special |
| Tenant | Space | Floors | Renovation projects |
|---|---|---|---|
| T H E P R E M I U M B U D D I S P E N S A R Y S T O R E | Retail | Sub-basement, Floor 1, Roof | Project X01442648 |