← Back
Self-storage warehouse
47-20 DUTCH KILLS STREET
QUEENS · Long Island City-Hunters Point · BIN 4467706
💬 Discuss this project
2001Year Built
3Stories
E7Building Class
M3-2Zoning
116,645 sfGross Floor Area
1Units
LL97 Covered1 Open Violation ▸FDNY Report ↗
Self-storage warehouse · Owner of record: LIC NON-RECOURSE LLC · 43,491 sf lot · 2.68 FAR built · Flood zone X500
Locations of Work
ArchitectureStructuralMechanicalPlumbingFire Protection
Roof72p · 4 filings · 20 docs
Floor 366p · 3 filings · 20 docs
Floor 265p · 3 filings · 20 docs
Floor 194p · 5 filings · 20 docs
Cellar72p · 3 filings · 20 docs
Sub-Cellar60p · 2 filings · 20 docs
Site & exterior3p · 1 filing · 2 docs
▾Owner History (Filing Record)
Companies and organizations named on filings. Individual owners are not shown.
OwnerFilingsMost Recent
21ST CENTURY STORAGE2507/08/2026
29TH STREET603/21/2026
ANOROC REALTY403/21/2026
LIC NON-RECOURSE LLC103/22/2026
59TH STREET BRIDGE PLAZA103/21/2026
▾Sales History (ACRIS)
DatePriceUnitSeller → Buyer$/sf
04/06/2021$18.2M—29TH STREET ASSOCIATES, LLC → LIC NON-RECOURSE LLC$156/sf building
▾Design Consultants (Architect / Engineer of Record)
▾Filing Representatives (Expediters)
RepresentativeFilingsMost Recent
RAND ENGINEERING ARCHITECTURE DPC2203/21/2026
JULIAN A. GOMEZ203/21/2026
SYNERGY BUILDING CONSULTANTS103/21/2026
▾Contractors (License-Anchored)
FirmTradeRolesMost Recent
WESBUILT CONSTRUCTION MANGeneral Contractor907/08/2026
CAPITOL FIRE SPRINKLER COFire Protection107/08/2026
UNIVERSAL FIRE SPR LLCFire Protection107/08/2026
CS BRIDGE CORPGeneral Contractor107/08/2026
METROTECH MECHANICAL CORPPlumbing107/08/2026
▾Special Inspection Agencies
AgencyLicense #FilingsMost Recent
RAND ENGINEERING & ARCHIT2661003/19/2024
Building Lifecycle
All (132)Filed (13)Permit Issued (11)Signed Off (3)Violation (60)Inspection (3)Objection (12)Special Inspection (30)
03/19/2026
Violation issued (FDNY_NOV, closed)
03/19/2026
Violation issued (FDNY_ORDER, closed)
03/19/2026
Violation issued (FDNY_ORDER, closed)
03/19/2026
Violation issued (FDNY_ORDER, closed)
03/19/2026
Violation issued (FDNY_NOV, closed)
03/19/2026
Violation issued (ECB, closed)
Construction
03/19/2026
Violation issued (ECB, closed)
Construction
12/23/2025
Violation issued (FDNY_NOV, closed)
12/23/2025
Violation issued (FDNY_NOV, closed)
11/10/2025
Violation issued (FDNY_NOV, closed)
01/30/2025
Violation issued (FDNY_NOV, closed)
01/30/2025
Violation issued (FDNY_NOV, closed)
04/11/2024
Special inspection requirement — Structural Steel - Details
James Vignola
04/11/2024
Special inspection requirement — Post-installed Anchors
James Vignola
04/11/2024
Special inspection requirement — Masonry
James Vignola
04/11/2024
Special inspection requirement — Structural Steel - High Strength Bolting
James Vignola
04/11/2024
Special inspection requirement — Concrete - Cast-In-Place
James Vignola
04/11/2024
Special inspection requirement — Structural Steel - Welding
James Vignola
04/11/2024
Special inspection requirement — Final
James Vignola
04/11/2024
Special inspection requirement — Structural Cold-Formed Steel
James Vignola
04/01/2024
Special inspection requirement — Interior lighting power
Peter Varsalona
04/01/2024
Special inspection requirement — Energy Code Compliance Inspections
Peter Varsalona
04/01/2024
Special inspection requirement — Lighting controls
Peter Varsalona
04/01/2024
Special inspection requirement — Fire-Resistant Penetrations and Joints
Peter Varsalona
04/01/2024
Special inspection requirement — Post-installed Anchors
Peter Varsalona
04/01/2024
Special inspection requirement — Masonry
Peter Varsalona
04/01/2024
Special inspection requirement — Structural Stability – Alterations of existing buildings
Peter Varsalona
04/01/2024
Special inspection requirement — Final
Peter Varsalona
04/01/2024
Special inspection requirement — Preliminary
Peter Varsalona
03/29/2024
Special inspection requirement — HVAC-R and service water piping design and insulation
Peter Varsalona
03/29/2024
Special inspection requirement — Mechanical Systems
Peter Varsalona
03/29/2024
Special inspection requirement — Preliminary
Peter Varsalona
03/29/2024
Special inspection requirement — Final
Peter Varsalona
03/29/2024
Special inspection requirement — Energy Code Compliance Inspections
Peter Varsalona
03/29/2024
Special inspection requirement — Shutoff dampers
Peter Varsalona
03/26/2024
Objection resolved — Addressed
03/26/2024
Objection resolved — Addressed
03/25/2024
Objection raised — Inspections
03/25/2024
Objection raised — Scope
03/19/2024
Filed — Alteration
Mechanical related work for Capital Improvement Program such as Removal & disposal of existing HVAC evaporators & condenser units, install new HVAC system, VRF split AC system, electric wall mounted walls, exhaust fan, fresh air intake fans and ductwork.
Q00618409-P1
03/13/2024
Filed — Alteration
Capital improvement program includes renovation with new walls, finishes, ceilings, millwork. No change to use, egress or occupancy.
Q00664952-P2
03/08/2024
Filed — Alteration
Structural related work for Capital Improvement Program. No change to use, egress or occupancy.
Q00618331-P1
02/23/2024
Signed off — Alteration
Removal, replacement, relocation and installation of new sprinkler heads at first floor levels as noted on plans including new sprinkler branch piping as needed. No change to use, egress or occupancy.
Q00670444-I1
02/22/2024
Special inspection requirement — Post-installed Anchors
Peter Varsalona
02/22/2024
Special inspection requirement — Structural Stability – Alterations of existing buildings
Peter Varsalona
02/22/2024
Special inspection requirement — Energy Code Compliance Inspections
Peter Varsalona
02/22/2024
Special inspection requirement — Final
Peter Varsalona
02/22/2024
Special inspection requirement — Preliminary
Peter Varsalona
02/22/2024
Special inspection requirement — Lighting controls
Peter Varsalona
02/22/2024
Special inspection requirement — Interior lighting power
Peter Varsalona
01/10/2024
Inspection — Certified Sprinkler-SP-Fixtures-Finish
Certified
View inspection ↗
01/08/2024
Inspection — Certified Remove/Cap - work done in accordance with code
Certified
View inspection ↗
01/08/2024
Inspection — Certified Sprinkler-SP-Piping Dry/Wet-Hydrostatic Test
Certified
View inspection ↗
10/03/2023
Signed off — Alteration
Installation of temporary supported scaffold per plan submitted. Work shall comply with 2014 building codes chapter 33. No change in use, egress and/or occupancy with this application.
Q07995083-I1
08/19/2023
Objection resolved — Addressed
08/19/2023
Objection resolved — Addressed
08/19/2023
Objection resolved — Addressed
07/31/2023
Objection raised — Structural
07/31/2023
Objection raised — Inspections
07/31/2023
Objection raised — Scope
Latest 60 of 132 events.
Permit / Filing Register
SourceWork TypeStatusApplicantIssued
DOB NOWGeneral ConstructionPermit IssuedWESBUILT CONSTRUCTION MAN03/15/2023
DOB NOWMechanical SystemsPermit IssuedWESBUILT CONSTRUCTION MAN03/15/2023
DOB NOWStructuralPermit IssuedWESBUILT CONSTRUCTION MAN03/15/2023
DOB NOWSprinklersSigned-offCAPITOL FIRE SPRINKLER CO02/13/2023
DOB NOWSprinklersSigned-offUNIVERSAL FIRE SPR LLC11/14/2022
DOB NOWSupported ScaffoldSigned-offCS BRIDGE CORP09/02/2022
DOB NOWGeneral ConstructionPermit IssuedWESBUILT CONSTRUCTION MAN08/18/2022
DOB NOWStructuralPermit IssuedWESBUILT CONSTRUCTION MAN08/09/2022
DOB NOWPlumbingPermit IssuedMETROTECH MECHANICAL CORP07/16/2022
DOB NOWMechanical SystemsPermit IssuedWESBUILT CONSTRUCTION MAN06/28/2022
DOB NOWMechanical SystemsSigned-offPETER VARASALONA01/27/2022
BISPLISSUEDC.R.U. MECHAN & HEAT INC04/02/2002
BISEQISSUEDBROADWAY STAGES03/26/2002
BISOTISSUEDBROADWAY STAGES03/26/2002
BISPLISSUEDCAPE PLUMBING INC03/29/2001
BIS—ISSUEDNATIONAL STORAGE PARTNERS LLC02/15/2001
BISPLISSUEDALJER PLBG & HTG CORP01/29/1999
BISMHISSUEDVANGUARD CONSTRUCTION AND10/19/1998
BISOTISSUEDVANGUARD CONSTRUCTION AND10/16/1998
1 project · most recent 03/19/2024
Air Conditioning Systems
FiledStatusContractorScopeMake / Model / Capacity
03/19/2024Permit IssuedWESBUILT CONSTRUCTION MANAir Conditioning Systems
Cooling
Lg ARNU483V2A4 (940 CFM Each) 940 CFM · Vrf Indoor ×4
LSN180HFV3 360 CFM · Split System ×4
LSU180HFV3 (18,500 BTU each) 18,500 BTU · Condensing Unit ×4
ARUN096BSS5 8 tons · Vrf Outdoor ×2
Carrier Carrier - 38AUD (188,000 BTU each Condenser) 188,000 BTU · Condensing Unit ×4
Carrier - 39SV (6000 CFM each) 6,000 CFM · Ahu ×4
Trane GBC0603E--E0-0-1 2,000 CFM · Furnace ×2
3 projects · most recent 04/06/2026
General Wiring
FiledStatusContractorScope
04/06/2026CompleteJP & SON ELECTRIC CORPGeneral Wiring
03/19/2026Permit IssuedMAX ELECTRIC CO., INCGeneral Wiring
09/12/2022CompleteCAPUTEK ELEC'L SERVICES,—
1 project · most recent 03/08/2024
Steel Concrete Masonry
FiledStatusContractorScope
03/08/2024Permit IssuedWESBUILT CONSTRUCTION MANSteel, Concrete, Masonry
▾Field Inspections (DOB CAP) — 3
DateTypeResultReport
01/10/2024Certified Sprinkler-SP-Fixtures-FinishCertifiedView ↗
01/08/2024Certified Remove/Cap - work done in accordance with codeCertifiedView ↗
01/08/2024Certified Sprinkler-SP-Piping Dry/Wet-Hydrostatic TestCertifiedView ↗
▾Special Inspection Requirements (DOB NOW) — 39
DateRequirementInspectorRole
04/11/2024Structural Steel - DetailsJames Vignolaspecial
04/11/2024Post-installed AnchorsJames Vignolaspecial
04/11/2024MasonryJames Vignolaspecial
04/11/2024Structural Steel - High Strength BoltingJames Vignolaspecial
04/11/2024Concrete - Cast-In-PlaceJames Vignolaspecial
04/11/2024Structural Steel - WeldingJames Vignolaspecial
04/11/2024FinalJames Vignolaprogress
04/11/2024Structural Cold-Formed SteelJames Vignolaspecial
04/01/2024Interior lighting powerPeter Varsalonaenergy_progress
04/01/2024Energy Code Compliance InspectionsPeter Varsalonaprogress
04/01/2024Lighting controlsPeter Varsalonaenergy_progress
04/01/2024Fire-Resistant Penetrations and JointsPeter Varsalonaspecial
04/01/2024Post-installed AnchorsPeter Varsalonaspecial
04/01/2024MasonryPeter Varsalonaspecial
04/01/2024Structural Stability – Alterations of existing buildingsPeter Varsalonaspecial
04/01/2024FinalPeter Varsalonaprogress
04/01/2024PreliminaryPeter Varsalonaprogress
03/29/2024HVAC-R and service water piping design and insulationPeter Varsalonaenergy_progress
03/29/2024Mechanical SystemsPeter Varsalonaspecial
03/29/2024PreliminaryPeter Varsalonaprogress
03/29/2024FinalPeter Varsalonaprogress
03/29/2024Energy Code Compliance InspectionsPeter Varsalonaprogress
03/29/2024Shutoff dampersPeter Varsalonaenergy_progress
02/22/2024Post-installed AnchorsPeter Varsalonaspecial
02/22/2024Structural Stability – Alterations of existing buildingsPeter Varsalonaspecial
Latest 25 of 39.
▾Documents — 54 on file (BIS + DOB NOW)
▸Plans & Drawings13
▸DOB NOWPlans/Sketch13
08/26/2026Q00643815-I1Request digital key ↗
08/26/2026Q00650269-I1Request digital key ↗
08/26/2026Q00650269-P1Request digital key ↗
Showing 3 of 13 on file for this type
▸Seals & Professional Certifications30
▸DOB NOWDPL-1: Design Professional Seal & Signature13
08/26/2026Q00670444-P1Open ↗
08/26/2026Q00670444-I1Open ↗
08/23/2026Q00618331-I1Open ↗
Showing 3 of 13 on file for this type
▸DOB NOWProgress Inspector Seal & Signature9
09/01/2026Q00664952-I1Open ↗
09/01/2026Q00664952-I1Open ↗
08/31/2026Q00618331-I1Open ↗
Showing 3 of 9 on file for this type
▸DOB NOWSpecial Inspector Seal & Signature8
09/01/2026Q00664952-I1Open ↗
08/31/2026Q00618331-I1Open ↗
08/31/2026Q00618331-I1Open ↗
Showing 3 of 8 on file for this type
▸Environmental & Asbestos11
▸DOB NOWDEP ACP-5: Asbestos Assessment Report11
08/26/2026Q00670444-I1Open ↗
08/26/2026Q00670444-P1Open ↗
08/23/2026Q00618331-I1Open ↗
Showing 3 of 11 on file for this type