← Back
Two family brick
47-26 39 STREET
QUEENS · BIN 4003239
💬 Discuss this project
1930Year Built
2Stories
B1Building Class
R5Zoning
2,700 sfGross Floor Area
2Units
0 Open Violations
Two family brick · 2,340 sf lot · 1.15 FAR built · Flood zone X
Locations of Work
No floor-level scope or drawing coverage on file for this building.
▾Sales History (ACRIS)
DatePriceUnitSeller → Buyer$/sf
10/12/2023$1.4M—— → —$513/sf building
▾Design Consultants (Architect / Engineer of Record)
FirmFilingsMost Recent
ALPHA HOME DESIGN LLC305/01/2024
▾Filing Representatives (Expediters)
RepresentativeFilingsMost Recent
FANG ARCHITECT303/21/2026
▾Contractors (License-Anchored)
FirmTradeRolesMost Recent
HOME STYLE IMPROVEMENTS *General Contractor303/21/2026
JOHN FITZGERALD PLBG &HTGPlumbing107/08/2026
▾Special Inspection Agencies
AgencyLicense #FilingsMost Recent
YAN GAO6619305/01/2024
Building Lifecycle
All (30)Filed (3)Permit Issued (2)Signed Off (2)Violation (2)Inspection (5)Special Inspection (16)
06/21/2024
Signed off — Alteration
FIELD PLUMBING WORK FOR EXISTING 2-FAMILY DWELLING. NO CHANGE TO EXIST. USE, EGRESS & OCCUPANCY. OIL TO GAS CONVERSION
Q00959428-S1
06/21/2024
Signed off — Alteration
FIELD PLUMBING WORK FOR EXISTING 2-FAMILY DWELLING. NO CHANGE TO EXIST. USE, EGRESS & OCCUPANCY. OIL TO GAS CONVERSION
Q00959428-I1
06/20/2024
Inspection — Pass-Final General Construction Non-Directive 14
Pass
View inspection ↗
06/05/2024
Inspection — Fail-Final General Construction Non-Directive 14
Fail
View inspection ↗
05/01/2024
Filed — Alteration
FIELD PLUMBING WORK FOR EXISTING 2-FAMILY DWELLING. NO CHANGE TO EXIST. USE, EGRESS & OCCUPANCY. OIL TO GAS CONVERSION
Q00959428-P1
04/30/2024
Special inspection requirement — Concrete - Cast-In-Place
YAN GAO
04/30/2024
Special inspection requirement — Fire-Resistant Penetrations and Joints
YAN GAO
04/30/2024
Special inspection requirement — Masonry
YAN GAO
04/30/2024
Special inspection requirement — Energy Code Compliance Inspections
YAN GAO
04/30/2024
Special inspection requirement — Fire-Resistance Rated Construction
YAN GAO
04/30/2024
Special inspection requirement — Insulation placement and R values
YAN GAO
04/30/2024
Special inspection requirement — Fenestration air leakage
YAN GAO
04/30/2024
Special inspection requirement — Fenestration areas
YAN GAO
04/30/2024
Special inspection requirement — Fenestration and door U-factor and product ratings
YAN GAO
04/30/2024
Special inspection requirement — Interior lighting power
YAN GAO
01/26/2024
Inspection — Certified Gas-Gas-Piping-Roughing
Certified
View inspection ↗
01/26/2024
Inspection — Certified Water and Sanitary-WS-Sanitary Piping-Roughing
Certified
View inspection ↗
01/26/2024
Inspection — Certified Water and Sanitary-WS-Sanitary Piping-Underground
Certified
View inspection ↗
01/16/2024
Permit issued — Plumbing
Q00959428-S1-PL
11/21/2023
Filed — Alteration
FIELD PLUMBING WORK FOR EXISTING 2-FAMILY DWELLING. NO CHANGE TO EXIST. USE, EGRESS & OCCUPANCY. OIL TO GAS CONVERSION
Q00959428-S1
11/20/2023
Permit issued — General Construction
Q00959428-I1-GC
11/16/2023
Filed — Alteration
FIELD PLUMBING WORK FOR EXISTING 2-FAMILY DWELLING. NO CHANGE TO EXIST. USE, EGRESS & OCCUPANCY. OIL TO GAS CONVERSION
Q00959428-I1
11/16/2023
Special inspection requirement — Fire-Resistant Penetrations and Joints
YAN GAO
11/16/2023
Special inspection requirement — Energy Code Compliance Inspections
YAN GAO
11/16/2023
Special inspection requirement — Maintenance information
YAN GAO
11/16/2023
Special inspection requirement — HVAC-R and service water heating system controls
YAN GAO
11/16/2023
Special inspection requirement — HVAC-R and service water heating equipment
YAN GAO
11/16/2023
Special inspection requirement — HVAC-R and service water piping design and insulation
YAN GAO
08/03/2015
Violation issued (HPD, closed)
A
08/03/2015
Violation issued (HPD, closed)
B
Permit / Filing Register
SourceWork TypeStatusApplicantIssued
DOB NOWPlumbingSigned-offJOHN FITZGERALD PLBG &HTG01/16/2024
DOB NOWGeneral ConstructionSigned-offHOME STYLE IMPROVEMENTS *11/20/2023
BISOTISSUEDINSIGHT CONSTRUCTION SERV10/22/2020
BISOTISSUEDINSIGHT CONSTRUCTION SERV09/22/2020
1 project · most recent 12/12/2023
General Wiring
FiledStatusContractorScope
12/12/2023CompleteGOODALL ELECTRIC CORPGeneral Wiring
▾Field Inspections (DOB CAP) — 5
DateTypeResultReport
06/20/2024Pass-Final General Construction Non-Directive 14PassView ↗
06/05/2024Fail-Final General Construction Non-Directive 14FailView ↗
01/26/2024Certified Gas-Gas-Piping-RoughingCertifiedView ↗
01/26/2024Certified Water and Sanitary-WS-Sanitary Piping-RoughingCertifiedView ↗
01/26/2024Certified Water and Sanitary-WS-Sanitary Piping-UndergroundCertifiedView ↗
▾Special Inspection Requirements (DOB NOW) — 16
DateRequirementInspectorRole
04/30/2024Concrete - Cast-In-PlaceYAN GAOspecial
04/30/2024Fire-Resistant Penetrations and JointsYAN GAOspecial
04/30/2024MasonryYAN GAOspecial
04/30/2024Energy Code Compliance InspectionsYAN GAOprogress
04/30/2024Fire-Resistance Rated ConstructionYAN GAOprogress
04/30/2024Insulation placement and R valuesYAN GAOenergy_progress
04/30/2024Fenestration air leakageYAN GAOenergy_progress
04/30/2024Fenestration areasYAN GAOenergy_progress
04/30/2024Fenestration and door U-factor and product ratingsYAN GAOenergy_progress
04/30/2024Interior lighting powerYAN GAOenergy_progress
11/16/2023Fire-Resistant Penetrations and JointsYAN GAOspecial
11/16/2023Energy Code Compliance InspectionsYAN GAOprogress
11/16/2023Maintenance informationYAN GAOenergy_progress
11/16/2023HVAC-R and service water heating system controlsYAN GAOenergy_progress
11/16/2023HVAC-R and service water heating equipmentYAN GAOenergy_progress
11/16/2023HVAC-R and service water piping design and insulationYAN GAOenergy_progress
▾Documents — 30 on file (BIS + DOB NOW)
▸Plans & Drawings3
▸DOB NOWPlans/Sketch3
08/23/2026Q00959428-I1Request digital key ↗
08/23/2026Q00959428-P1Request digital key ↗
08/23/2026Q00959428-S1Request digital key ↗
▸Applications & Permits1
▸BISWORK PERMIT APPLICATION1
09/22/2020440624790Open ↗
▸Zoning, Tax Lot & Property Records1
▸DOB NOWRestrictive Declaration/Easement 11
08/13/2026Q00959428-S1Open ↗
▸Seals & Professional Certifications10
▸DOB NOWProgress Inspector Seal & Signature4
08/30/2026Q00959428-P1Open ↗
08/30/2026Q00959428-P1Open ↗
08/25/2026Q00959428-S1Open ↗
Showing 3 of 4 on file for this type
▸DOB NOWDPL-1: Design Professional Seal & Signature3
08/23/2026Q00959428-P1Open ↗
08/23/2026Q00959428-S1Open ↗
08/23/2026Q00959428-I1Open ↗
▸DOB NOWSpecial Inspector Seal & Signature2
08/30/2026Q00959428-P1Open ↗
08/25/2026Q00959428-S1Open ↗
▸BISAPPLICANT OWNER SIGNATURE1
09/09/2020440624790Open ↗
▸Environmental & Asbestos4
▸DOB NOWDEP ACP-5: Asbestos Assessment Report3
08/23/2026Q00959428-S1Open ↗
08/23/2026Q00959428-P1Open ↗
08/23/2026Q00959428-I1Open ↗
▸BISASBESTOS: CERTIFICATION (DEP ACP5)1
09/09/2020440624790Open ↗
▸Energy Compliance4
▸BISTECHNICAL REPORT: ENERGY CODE - RESPONSIBILITY2
09/16/2020440624790Open ↗
09/09/2020440624790Open ↗
▸BISAS-BUILT ENERGY ANALYSIS (EN2)1
10/07/2022440624790Open ↗
▸BISENERGY CODE COMPLIANCE INSPECTIONS1
10/07/2022440624790Open ↗
▸Inspections & Test Reports3
▸BISFINAL INSPECTION (BB 2018-008)1
10/12/2022440624790Open ↗
▸BISTECHNICAL REPORT: RESPONSIBILITY1
09/09/2020440624790Open ↗
▸BISUPDATED TR1 FORM (AC 28-104.7)1
09/18/2020440624790Open ↗
▸Approvals, Objections & Sign-offs1
▸BISCERTIFICATE OF OCCUPANCY/LOC: REQUEST1
10/12/2022440624790Open ↗
▸Cost, Insurance & Ownership2
▸BISCOST AFFIDAVIT1
09/09/2020440624790Open ↗
▸BISCOST AFFIDAVIT (FINAL): PW31
10/07/2022440624790Open ↗
▸Filing & Intake Forms1
▸BISEFILING JOB APPLICATION COVER SHEET1
09/09/2020440624790Open ↗